Patient Demographics and Scanning Parameters.
| Protocol A | Protocol B | P | |
| Number of patients | 46 | 46 | |
| Male/Female | 25/21 | 24/22 | 0.83 |
| Age(y) | 55.3±8.6 | 56.9±10 | 0.42 |
| Body Weight(kg) | 67±8.7 | 67.8±12.4 | 0.72 |
| BMI(kg/m2) | 24.3±3 | 23.9±3 | 0.5 |
| Scan length(cm) | 36.2±2.1 | 35.8±2.3 | 0.43 |
| Concentration of contrast media (mgI/ml) | 320 | 270 |
BMI: Body mass index, calculated as weight (kg)/(height in m)2.
Figure 1Determination of image noise, vascular attenuation.
The CT attenuation value was measured at circular regions of interest (ROI) placed in the center of common carotid arteries. Data were shown as mean ± standard deviation. Additional ROIs were placed at the sternocleidomastoid muscle adjacent to the vessel contour.
Radiation Dose.
| Protocol A | Protocol B | P | |
| CTDI (mGy) | 7.8±0.9 | 3.9±0.5 | <0.001 |
| DLP(mGy*cm) | 379±48.1 | 189.5±26.4 | <0.001 |
CTDI: computed tomography dose index, DLP: dose length product, ED: effective dose.
Quantitative image quality.
| Protocol A | Protocol B | P | |
| CT number(HU) | |||
| Ascending aorta | 421.8±61.1 | 598.1±85.8 | <0.001 |
| Common carotid arteries | 553.3±91.5 | 735.7±124.6 | <0.001 |
| Internal carotid arteries | 531.5±87.2 | 681.6±99.9 | <0.001 |
| Middle cerebral arteries | 485.1±69.1 | 611.5±99.6 | <0.001 |
| Image noise(HU) | 40.4±5.3 | 37.5±5.2 | 0.11 |
| CNR | |||
| Ascending aorta | 8.6±1.9 | 13.7±1.7 | <0.001 |
| Common carotid arteries | 11.2±2.9 | 16.6±2.8 | <0.001 |
| Internal carotid arteries | 11±2.5 | 15.6±2.5 | <0.001 |
| Middle cerebral arteries | 11±2.2 | 15.1±2.6 | <0.001 |
CNR: Contrast-to-noise ratio.
Four patients were excluded from measurements of internal carotid arteries and middle cerebral arteries due to the occlusion of lumens in protocol B.
Qualitative image quality.
| Protocol A | Protocol B | P | |
| (Percentiles, P25, P75) | (Percentiles, P25, P75) | ||
| Grassiness | (2,2) | (3,3) | <0.001 |
| Vessel sharpness | (3,4) | (3,4) | 0.59 |
| Streak artifact | (2,3) | (3,3) | <0.001 |
| Overall image quality | (3,3) | (3,3) | 0.74 |
Figure 2The images compared between two protocols.
(a–c) CT images in a 64-year-old woman (BM, 62 kg; BMI, 26.84) in protocol A. (d–f) CT images in another 64-year-old woman (BM, 68 kg; BMI, 26.56) in protocol B. (a) and (d) axial images; (b) and (e) volume rendered images; (c) and (f) curved planar reconstructed images. The images in protocol B with iterative reconstruction decreased the streak artifacts and noises without losing the vessel sharpness and image quality.