Literature DB >> 18331808

Technical approaches to the optimisation of CT.

Willi A Kalender1, Stefanie Buchenau, Paul Deak, Markus Kellermeier, Oliver Langner, Marcel van Straten, Sabrina Vollmar, Sylvia Wilharm.   

Abstract

This paper reviews current technical approaches to the optimisation of CT practice, i.e. approaches to reduce patient dose to the necessary minimum. The most important step towards this goal appears to be the technology of tube current modulation (TCM), which came into practice in the early 2000s and has become the standard approach recently. Anatomy- or attenuation-based TCM allows for a dose reduction between 10 and 60% as compared to scans with constant tube current. Automatic exposure control (AEC) approaches are the next step; based on TCM technology, AEC adapts the tube current both with the rotation angle alpha (alpha-modulation) and along the z-axis (z-modulation) to achieve a pre-selected image quality level at minimal dose. To pre-select the image quality level, i.e. primarily the pixel noise level, tools for simulation are important to investigate the necessary noise levels pro- and retrospectively for given cases and diagnostic tasks. Respective "dose tutor" approaches have become available recently and are presented. The most recent technical innovation which may lead to substantial dose reduction is the investigation of optimal spectra taking the type of contrast and 3D dose distributions into account. A high potential has been shown especially for pediatric CT and for thoracic CT where dose reduction of a factor of 2 and more is possible when using reduced tube voltages.

Entities:  

Mesh:

Year:  2008        PMID: 18331808     DOI: 10.1016/j.ejmp.2008.01.012

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  45 in total

1.  [Principles of multidetector-row computed tomography. Part 2: determinants of radiation exposure and current technical developments].

Authors:  W Stiller
Journal:  Radiologe       Date:  2011-12       Impact factor: 0.635

2.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

3.  64-row MDCT perfusion of head and neck squamous cell carcinoma: technical feasibility and quantitative analysis of perfusion parameters.

Authors:  Lorenzo Faggioni; Emanuele Neri; Francesca Cerri; Eugenia Picano; Veronica Seccia; Luca Muscatello; Stefano Sellari Franceschini; Carlo Bartolozzi
Journal:  Eur Radiol       Date:  2010-07-23       Impact factor: 5.315

4.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients.

Authors:  François Pontana; Julien Pagniez; Thomas Flohr; Jean-Baptiste Faivre; Alain Duhamel; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2010-11-05       Impact factor: 5.315

Review 5.  [Radiation hygiene in medical X-ray imaging: part 2: Assessment of radiation exposure and radiation protection measures].

Authors:  G Brix; R Veit; U Häusler
Journal:  Radiologe       Date:  2010-10       Impact factor: 0.635

6.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

7.  Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study.

Authors:  Katharina Martini; Kai Higashigaito; Borna K Barth; Stephan Baumueller; Hatem Alkadhi; Thomas Frauenfelder
Journal:  Br J Radiol       Date:  2015-10-22       Impact factor: 3.039

8.  Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation.

Authors:  U Lechel; C Becker; G Langenfeld-Jäger; G Brix
Journal:  Eur Radiol       Date:  2008-11-06       Impact factor: 5.315

9.  Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.

Authors:  Daniela B Husarik; Sebastian T Schindera; Fabian Morsbach; Natalie Chuck; Burkhardt Seifert; Zsolt Szucs-Farkas; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-10-24       Impact factor: 5.315

10.  Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction.

Authors:  Touko Kaasalainen; Kirsi Palmu; Anniina Lampinen; Vappu Reijonen; Junnu Leikola; Riku Kivisaari; Mika Kortesniemi
Journal:  Pediatr Radiol       Date:  2015-05-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.