Literature DB >> 21723684

Carotid CT-angiography: low versus standard volume contrast media and low kV protocol for 128-slice MDCT.

Mustafa Kayan1, Mert Köroğlu, Ahmet Yeşildağ, Ergun Ceylan, Aykut Recep Aktaş, Selçuk Yasar, Giray Aynali, Cem Parlak, Mehmet Munduz, Cemil Gürses.   

Abstract

Availability and utilization of computed tomography angiography has been increasing recently. We aimed to assess the effectiveness of low amount of contrast media and low kV value in order to reduce possible side effects of contrast media and to provide optimization of kV value in the evaluation of the carotid artery with multi-detector computed tomography angiography. Forty one patients were randomized into two groups. Contrast media was administered at a dose of 1 ml/kg in group A patients and of 0.5 ml/kg in group B patients. kV value of 120 in group A and 100 in group B were chosen. Bolus tracking technique was used. Attenuation values of certain arterial segments were measured, and values over 200 HU were considered as significant. North American Symptomatic Carotid Endartherectomy Trial criteria were utilized in the evaluation of stenosis. Image quality in arterial segments of all cases was found to be sufficient for diagnosis. Arterial attenuation values were found to be higher in group B than group A. When compared separately in all arterial segments, there was no statistically significant difference between the groups. For stenosis, 615 arterial segments were evaluated. Moderate stenosis in eight segments and severe stenosis in three segments were identified in group A. Occlusion in three segments, severe stenosis in three segments, and moderate stenosis in 25 segments were detected in group B. Better image quality can be obtained, and the amount of contrast media can be reduced using low kV technique in carotid artery multi-detector computed tomography angiography examination.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21723684     DOI: 10.1016/j.ejrad.2011.05.006

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  7 in total

1.  Impact of organ-specific dose reduction on the image quality of head and neck CT angiography.

Authors:  L Schimmöller; R S Lanzman; P Heusch; S Dietrich; F Miese; J Aissa; T A Heusner; G Antoch; P Kröpil
Journal:  Eur Radiol       Date:  2013-01-09       Impact factor: 5.315

2.  Low-tube-voltage 80-kVp neck CT: evaluation of diagnostic accuracy and interobserver agreement.

Authors:  J L Wichmann; J Kraft; E-M Nöske; B Bodelle; I Burck; J-E Scholtz; C Frellesen; J Wagenblast; J M Kerl; R W Bauer; T Lehnert; T J Vogl; B Schulz
Journal:  AJNR Am J Neuroradiol       Date:  2014-08-07       Impact factor: 3.825

3.  Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography.

Authors:  Jan-Erik Scholtz; Moritz Kaup; Johannes Kraft; Eva-Maria Nöske; Friedrich Scheerer; Boris Schulz; Iris Burck; Jens Wagenblast; J Matthias Kerl; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Neuroradiology       Date:  2015-03-26       Impact factor: 2.804

4.  Efficacy of fine focal spot technique in CT angiography of neck.

Authors:  Lawrence Chia-Wei Oh; Kenneth Kwok-Pan Lau; Ashwini Devapalasundaram; Kevin Buchan; Ahilan Kuganesan; Minh Huynh
Journal:  Br J Radiol       Date:  2019-06-20       Impact factor: 3.039

5.  CT angiography of the head-and-neck vessels acquired with low tube voltage, low iodine, and iterative image reconstruction: clinical evaluation of radiation dose and image quality.

Authors:  Wei-lan Zhang; Min Li; Bo Zhang; Hai-yang Geng; Yin-qiang Liang; Ke Xu; Song-bai Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

6.  Interleaving cerebral CT perfusion with neck CT angiography. Part II: clinical implementation and image quality.

Authors:  Marcel T H Oei; Frederick J A Meijer; Willem-Jan van der Woude; Ewoud J Smit; Bram van Ginneken; Rashindra Manniesing; Mathias Prokop
Journal:  Eur Radiol       Date:  2016-09-21       Impact factor: 5.315

7.  Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography.

Authors:  Seyedeh Shokoofeh Mousavi-Gazafroudi; Amirreza Sajjadieh-Khajouei; Maryam Moradi; Seyedeh Shabnam Mousavi-Gazafroudi; Ghasem Yadegarfar; Mohammad Bagher Tavakoli
Journal:  ARYA Atheroscler       Date:  2019-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.