Literature DB >> 25636415

Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography.

Guo Zhong Chen1, Long Jiang Zhang, U Joseph Schoepf, Julian L Wichmann, Cole M Milliken, Chang Sheng Zhou, Li Qi, Song Luo, Guang Ming Lu.   

Abstract

OBJECTIVES: To evaluate radiation dose, image quality, and optimal level of sinogram-affirmed iterative reconstruction (SAFIRE) of cerebral CT angiography (CTA) at 70 kVp.
METHODS: One hundred patients were prospectively classified into two groups: Group A (n = 50), 70 kVp cerebral CTA with 5 levels of SAFIRE reconstruction (S1-S5); and Group B (n = 50), 120 kVp with filtered back projection (FBP) reconstruction. CT attenuation values, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the internal carotid artery (ICA) and middle cerebral artery (MCA) were measured. Subjective image quality was evaluated. Effective dose (ED) was estimated.
RESULTS: CT attenuation and noise of the ICA and MCA in Group A were higher than those of Group B (all P < 0.001) while the SNRICA, SNRMCA, CNRICA, and CNRMCA of Group A at S4-5 were comparable to (P > 0.05) or higher than in Group B (P < 0.05). There was no difference in overall image quality between Group A S3-5 and Group B (P > 0.05). ED was 0.2 ± 0.0 mSv for Group A with 85 % ED reduction in comparison to Group B (1.3 ± 0.2 mSv).
CONCLUSION: Cerebral CTA at 70 kVp is feasible, allowing for substantial radiation dose reduction. SAFIRE S4 level is recommended for obtaining optimal image quality. KEY POINTS: • 70 kVp cerebral CTA is feasible and provides diagnostic image quality. • 70 kVp cerebral CTA resulted in 85% effective dose reduction. • S4 level of SAFIRE is recommended for 70 kVp cerebral CTA.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25636415     DOI: 10.1007/s00330-014-3533-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

2.  Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Avinash K Kambadakone; Homer Pien; Jiang Hsieh; Michael A Blake; Dushyant V Sahani
Journal:  Invest Radiol       Date:  2010-04       Impact factor: 6.016

Review 3.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

4.  How far can the radiation dose be lowered in head CT with iterative reconstruction? Analysis of imaging quality and diagnostic accuracy.

Authors:  Tung-Hsin Wu; Sheng-Che Hung; Jing-Yi Sun; Chung-Jung Lin; Chung-Hsien Lin; Chen Fen Chiu; Min-Jsuan Liu; Michael Mu Huo Teng; Wan-Yuo Guo; Cheng-Yen Chang
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315

5.  Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Subba R Digumarthy; Jiang Hsieh; Homer Pien; Sarabjeet Singh; Matthew D Gilman; Jo-Anne O Shepard
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

6.  Feasibility of slice width reduction for spiral cranial computed tomography using iterative image reconstruction.

Authors:  Holger Haubenreisser; Christian Fink; John W Nance; Martin Sedlmair; Bernhard Schmidt; Stefan O Schoenberg; Thomas Henzler
Journal:  Eur J Radiol       Date:  2014-02-07       Impact factor: 3.528

7.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

8.  Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison.

Authors:  Wei-Hua Yin; Bin Lu; Nan Li; Lei Han; Zhi-Hui Hou; Run-Ze Wu; Yong-Jian Wu; Hong-Xia Niu; Shi-Liang Jiang; Aleksander W Krazinski; Ullrich Ebersberger; Felix G Meinel; U Joseph Schoepf
Journal:  JACC Cardiovasc Imaging       Date:  2013-10-23

9.  Detection of intracranial aneurysms: multi-detector row CT angiography compared with DSA.

Authors:  Mahesh V Jayaraman; William W Mayo-Smith; Glenn A Tung; Richard A Haas; Jeffrey M Rogg; Neerav R Mehta; Curtis E Doberstein
Journal:  Radiology       Date:  2003-12-29       Impact factor: 11.105

10.  CT angiography of the head-and-neck vessels acquired with low tube voltage, low iodine, and iterative image reconstruction: clinical evaluation of radiation dose and image quality.

Authors:  Wei-lan Zhang; Min Li; Bo Zhang; Hai-yang Geng; Yin-qiang Liang; Ke Xu; Song-bai Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

View more
  14 in total

1.  Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study.

Authors:  Xiao Kun Fang; Qian Qian Ni; U Joseph Schoepf; Chang Sheng Zhou; Guo Zhong Chen; Song Luo; Stephen R Fuller; Carlo N De Cecco; Long Jiang Zhang; Guang Ming Lu
Journal:  Eur Radiol       Date:  2016-02-06       Impact factor: 5.315

2.  Carotid CTA at the Lowest Tube Voltage (70 kV) in Comparison with Automated Tube Voltage Adaption.

Authors:  A Eller; M Wiesmüller; W Wüst; R Heiss; M Kopp; M Saake; M Brand; M Uder; M M May
Journal:  AJNR Am J Neuroradiol       Date:  2019-07-11       Impact factor: 3.825

3.  Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Hideaki Yuki; Kenichiro Hirarta; Seitaro Oda; Masafumi Kidoh; Daisuke Utsunomiya; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2017-01-03       Impact factor: 2.804

4.  Dual-energy CT angiography-derived virtual non-contrast images for follow-up of patients with surgically clipped aneurysms: a retrospective study.

Authors:  Su Young Yun; Young Jin Heo; Hae Woong Jeong; Jin Wook Baek; Hye Jung Choo; Gi Won Shin; Sung Tae Kim; Young Gyun Jeong; Ji Young Lee; Hyun Seok Jung
Journal:  Neuroradiology       Date:  2019-01-25       Impact factor: 2.804

5.  Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames.

Authors:  Robert Forbrig; Lucas L Geyer; Robert Stahl; Jun Thorsteinsdottir; Christian Schichor; Friedrich-Wilhelm Kreth; Maximilian Patzig; Moriz Herzberg; Thomas Liebig; Franziska Dorn; Christoph G Trumm
Journal:  Eur Radiol       Date:  2019-01-11       Impact factor: 5.315

6.  Head and neck angiography at 70 kVp with a third-generation dual-source CT system in patients: comparison with 100 kVp.

Authors:  Yu Chen; Xiaobo Zhang; Huadan Xue; Yuanli Zhu; Yun Wang; Yumei Li; Zhuhua Zhang; Zhengyu Jin
Journal:  Neuroradiology       Date:  2017-08-24       Impact factor: 2.804

7.  Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography.

Authors:  Guo Zhong Chen; Song Luo; Chang Sheng Zhou; Long Jiang Zhang; Guang Ming Lu
Journal:  Eur Radiol       Date:  2017-03-13       Impact factor: 5.315

8.  Cerebral CTA with Low Tube Voltage and Low Contrast Material Volume for Detection of Intracranial Aneurysms.

Authors:  Q Q Ni; G Z Chen; U J Schoepf; M A J Klitsie; C N De Cecco; C S Zhou; S Luo; G M Lu; L J Zhang
Journal:  AJNR Am J Neuroradiol       Date:  2016-05-05       Impact factor: 3.825

9.  Comparison of Imaging Selection Criteria for Intra-Arterial Thrombectomy in Acute Ischemic Stroke with Advanced CT.

Authors:  Eung Yeop Kim; Dong Hoon Shin; Young Noh; Byeong Ho Goh; Yeong-Bae Lee
Journal:  Eur Radiol       Date:  2015-12-08       Impact factor: 5.315

10.  Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose.

Authors:  Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Sung Min Ko
Journal:  PLoS One       Date:  2016-09-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.