Literature DB >> 21862771

Effects of iopamidol-370 versus iodixanol-320 on coronary contrast, branch depiction, and heart rate variability in dual-source coronary MDCT angiography.

Jared D Christensen1, Laura T Meyer, Lynne M Hurwitz, Daniel T Boll.   

Abstract

OBJECTIVE: The purpose of this article is to assess whether iopamidol-370 provides superior vascular contrast of the coronaries and depiction of anatomic detail without affecting heart rate and beat-to-beat variability during coronary dual-source MDCT compared with iodixanol-320. SUBJECTS AND METHODS: In this prospective trial, coronary CT angiography was performed on 60 adult patients using either iopamidol-370 or iodixanol-320. Cohorts were matched by age, habitus, sex, and baseline heart rate, with cohort sizes determined by power analysis. All studies were performed on a dual-source MDCT scanner with retrospective ECG-gating utilizing automatic pitch adjustment. Data assessment focused on heart rate variability during contrast administration statistically evaluated as Student t test comparisons within and between cohorts, coronary contrast-to-noise ratio analysis of the main coronary arteries utilizing Student t test comparisons between cohorts, and coronary branch depiction and distribution analysis in dual-reader consensus decisions between cohorts.
RESULTS: Thirty patients matched for age, habitus, sex, and heart rate were evaluated in each cohort. ECG analyses found a statistically significant (p = 0.013) decrease in heart rate during administration of iodixanol-320. Beat-to-beat variations, expressed as coefficient of variation, within and among cohorts were low (coefficient of variation, < 0.05). Contrast-to-noise ratio was significantly increased for iopamidol-370 versus iodixanol-320 (aortic root, p = 0.021; left main, p = 0.032; left anterior descending, p = 0.033; left circumflex, p = 0.039; and right, p = 0.009). Analysis of coronary branch visualization revealed improved depiction for iopamidol-370 compared with iodixanol-320.
CONCLUSION: Iopamidol-370, with its higher iodine concentration, provided greater vascular contrast of the arterial coronary tree and improved depiction of anatomic detail without significantly impacting cardiac heart rate during coronary MDCT imaging, as compared with iodixanol-320.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21862771     DOI: 10.2214/AJR.10.6154

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes.

Authors:  Jared D Christensen; Danielle M Seaman; Matthew P Lungren; Lynne M Hurwitz; Daniel T Boll
Journal:  Eur Radiol       Date:  2014-02-28       Impact factor: 5.315

2.  Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

Authors:  Guangming Ma; Yong Yu; Haifeng Duan; Yuequn Dou; Yongjun Jia; Xirong Zhang; Chuangbo Yang; Xiaoxia Chen; Dong Han; Changyi Guo; Taiping He
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

3.  Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320 hypo-osmolar iodine concentration contrasts.

Authors:  Annelisa Moura Garcia; Antonildes N Assunção-Jr; Roberto Nery Dantas-Jr; Jose Rodrigues Parga; Fernando Ganem
Journal:  Br J Radiol       Date:  2020-08-20       Impact factor: 3.039

4.  CT angiography of the head-and-neck vessels acquired with low tube voltage, low iodine, and iterative image reconstruction: clinical evaluation of radiation dose and image quality.

Authors:  Wei-lan Zhang; Min Li; Bo Zhang; Hai-yang Geng; Yin-qiang Liang; Ke Xu; Song-bai Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

5.  Contrast enhancement efficacy of iodinated contrast media: Effect of molecular structure on contrast enhancement.

Authors:  Kuniharu Imai; Mitsuru Ikeda; Yoshiki Satoh; Keisuke Fujii; Chiyo Kawaura; Takuya Nishimoto; Masaki Mori
Journal:  Eur J Radiol Open       Date:  2018-10-06

6.  Optimized heart rate for 320-row cardiac CT can be feasibly predicted from prescan parameters.

Authors:  Eriko Maeda; Nobuo Tomizawa; Kodai Yamamoto; Shigeaki Kanno; Masaaki Akahane; Kenji Ino; Masae Uehara; Aiko Sakamoto; Toshiaki Semboku; Rumiko Torigoe; Kuni Ohtomo
Journal:  Springerplus       Date:  2015-11-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.