Comparison of a low-osmolar contrast medium, iopamidol, and an iso-osmolar contrast medium, iodixanol, in MDCT coronary angiography.

Nilgun Isiksalan Ozbulbul1, Mehmet Yurdakul, Muharrem Tola.   

Abstract

OBJECTIVE: To prospectively compare iopamidol 370, which is a low-osmolar contrast medium and iodixanol 320, which is an iso-osmolar contrast medium, in terms of image quality and nonserious adverse effects that have the potential to influence the image quality in a 16-slice multi-detector row computed tomography coronary angiography.
METHODS: Sixty patients were divided into two groups to receive iodixanol 320 or iopamidol 370. Image quality was assessed, using a five-point grading scale. Differences in the mean attenuation (Hounsfield units) at the origin of the coronary arteries and on the ascending aorta in both the groups were compared. The number and intensity of adverse effects were compared between the two groups.
RESULTS: The mean attenuation values of the ascending aorta and the origins of the coronary arteries for the two groups showed no significant difference (P≥0.41). There was no significant difference in terms of image quality between the two groups on all evaluated segments. There was a statistically significant difference in the number of adverse effects (P=0.001) between the two groups. However, in both the iodixanol group and the iopamidol group, there was no significant difference in terms of image quality between the patients with and without adverse effects.
CONCLUSION: The frequency of adverse effects is lower in the iodixanol group than the iopamidol group. Iodixanol 320 can provide both vascular enhancement and image quality, which is similar to iopamidol 370 in a 16-slice multi-detector row computed tomography coronary angiography. There was no significant difference in terms of overall image quality between the patients with and without adverse effects in either of the groups.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20671550     DOI: 10.1097/MCA.0b013e328338cd0b

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  3 in total

1.  Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

Authors:  Guangming Ma; Yong Yu; Haifeng Duan; Yuequn Dou; Yongjun Jia; Xirong Zhang; Chuangbo Yang; Xiaoxia Chen; Dong Han; Changyi Guo; Taiping He
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

2.  CT angiography of the head-and-neck vessels acquired with low tube voltage, low iodine, and iterative image reconstruction: clinical evaluation of radiation dose and image quality.

Authors:  Wei-lan Zhang; Min Li; Bo Zhang; Hai-yang Geng; Yin-qiang Liang; Ke Xu; Song-bai Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

3.  Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography.

Authors:  Meng Zhang; Panpan Hao; Chenyu Jiang; Guoxiang Hao; Bin Li; Peixin Hu; Qingjie Chen; Yuguo Chen; Aifeng Zhang; Yun Zhang; Yanping Liu
Journal:  J Cell Mol Med       Date:  2020-03-30       Impact factor: 5.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.