Literature DB >> 15044744

Multi-detector row CT angiography of the brain at various kilovoltage settings.

Birgit B Ertl-Wagner1, Ralf-Thorsten Hoffmann, Roland Bruning, Karin Herrmann, Brad Snyder, Jeffrey D Blume, Maximilian F Reiser.   

Abstract

PURPOSE: To investigate image quality and vascular delineation of multi-detector row computed tomographic (CT) angiography at various kilovoltage settings.
MATERIALS AND METHODS: Thirty patients were investigated with a standardized CT protocol, with three groups of 10 consecutive patients examined at 80, 120, and 140 kV, respectively. Three blinded readers independently evaluated images and graded image quality parameters, diagnostic confidence, and vascular delineation of intracranial arteries and veins. Vascular CT attenuation values, CT dose indices, and dose length products were assessed quantitatively. For data analysis, a Kruskal-Wallis nonparametric rank F test was used to identify trends and variables that required modeling attention. A proportional odds multinomial regression model was then fit with generalized estimating equations to account for the correlated nature of the data.
RESULTS: Image quality was rated higher with higher kilovoltage settings (P <.001). The severity of imaging artifacts was higher with lower kilovoltage settings (P <.001), while the subjectively rated vessel contrast was lower in the 80-kV group than in the 120-kV group and the 140-kV group (P <.05). Diagnostic confidence was higher in the 120-kV group and 140-kV group (P <.005). Vascular delineation was higher with higher kilovoltage settings for most arterial and venous structures. Differences were more significant for structures in close topographic proximity to bone and for subsegmental arteries and were less significant and, in parts, not significant for the main arterial branches and the large venous sinus. Attenuation values were higher with lower kilovoltage settings (P <.05). The mean dose length product could be reduced from 594 mGy. cm in the 140-kV group to 152 mGy.cm in the 80-kV group.
CONCLUSION: This multireader study of image quality and vessel delineation with cranial multi-detector row CT angiography at various kilovoltage settings demonstrated a superiority of higher voltages with most pronounced effects for vessels adjacent to bone and subsegmental arteries.

Entities:  

Mesh:

Year:  2004        PMID: 15044744     DOI: 10.1148/radiol.2312030543

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  36 in total

1.  [Diagnostic evaluation of carotid artery stenoses with multislice CT angiography. Review of the literature and results of a pilot study].

Authors:  B Ertl-Wagner; R Brüning; R-T Hoffmann; G Meimarakis; M F Reiser
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

2.  Current status of low dose multi-detector CT in the urinary tract.

Authors:  Mi Kim Sung; Sarabjeet Singh; Mannudeep K Kalra
Journal:  World J Radiol       Date:  2011-11-28

3.  Dose reduction and image quality in CT angiography for cerebral aneurysm with various tube potentials and current settings.

Authors:  K Imai; M Ikeda; C Kawaura; T Aoyama; Y Enchi; M Yamauchi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

4.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

5.  Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Authors:  Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim
Journal:  Neuroradiology       Date:  2006-09-15       Impact factor: 2.804

6.  Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Authors:  Birgit B Ertl-Wagner; Roland Bruening; Jeffrey Blume; Ralf-Thorsten Hoffmann; Brad Snyder; Karin A Herrmann; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2005-03-19       Impact factor: 5.315

7.  Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration.

Authors:  Danielle Hernalsteen; Guy Cosnard; Annie Robert; Cécile Grandin; Alain Vlassenbroek; Thierry Duprez
Journal:  Eur Radiol       Date:  2006-08-16       Impact factor: 5.315

8.  Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose.

Authors:  B Wintersperger; T Jakobs; P Herzog; S Schaller; K Nikolaou; C Suess; C Weber; M Reiser; C Becker
Journal:  Eur Radiol       Date:  2004-12-21       Impact factor: 5.315

9.  64-Slice spiral computed tomography of the coronary arteries: dose reduction using an optimized imaging protocol including individual weight-adaptation of voltage and current-time product.

Authors:  Gunnar K Lund; Eckhard Wegian; Maythem Saeed; Jens Wassermeyer; Gerhard Adam; Alexander Stork
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

Review 10.  [Neurologic emergencies and multislice computed tomography].

Authors:  L Eftimov; D Morhard; M Reiser; B Ertl-Wagner
Journal:  Radiologe       Date:  2009-06       Impact factor: 0.635