Literature DB >> 22207302

Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction.

O Rapalino1, Shervin Kamalian, Shahmir Kamalian, S Payabvash, L C S Souza, D Zhang, J Mukta, D V Sahani, M H Lev, S R Pomerantz.   

Abstract

BACKGROUND AND
PURPOSE: To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients.
MATERIALS AND METHODS: Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed.
RESULTS: Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P < .01). CNR values were also significantly higher at ASIR levels of ≥40% (P < .01). Blinded qualitative review demonstrated significant improvements in perceived image noise, artifacts, and GM-WM differentiation at ASIR levels ≥60% (P < .01).
CONCLUSIONS: These results demonstrate that the use of ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.

Entities:  

Mesh:

Year:  2011        PMID: 22207302      PMCID: PMC8050448          DOI: 10.3174/ajnr.A2826

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  17 in total

1.  The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoid.

Authors:  Cynthia H McCollough; Michael R Bruesewitz; Michael F McNitt-Gray; Krista Bush; Thomas Ruckdeschel; J Thomas Payne; James A Brink; Robert K Zeman
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

3.  Iterative deblurring for CT metal artifact reduction.

Authors:  G Wang; D L Snyder; J A O'Sullivan; M W Vannier
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

Review 4.  CT technology overview: 64-slice and beyond.

Authors:  Patrik Rogalla; Christian Kloeters; Patrick A Hein
Journal:  Radiol Clin North Am       Date:  2009-01       Impact factor: 2.303

5.  The radiologist's conundrum: benefits and costs of increasing CT capacity and utilization.

Authors:  Giles W L Boland; Alexander S Guimaraes; Peter R Mueller
Journal:  Eur Radiol       Date:  2008-09-03       Impact factor: 5.315

Review 6.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

7.  Iterative reconstruction for helical CT: a simulation study.

Authors:  J Nuyts; B De Man; P Dupont; M Defrise; P Suetens; L Mortelmans
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

8.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

9.  Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Subba R Digumarthy; Jiang Hsieh; Homer Pien; Sarabjeet Singh; Matthew D Gilman; Jo-Anne O Shepard
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

10.  Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

View more
  39 in total

1.  Dramatically reducing imaging-to-recanalization time in acute ischemic stroke: making choices.

Authors:  M Goyal; M A Almekhlafi
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

2.  Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels.

Authors:  A Löve; M-L Olsson; R Siemund; F Stålhammar; I M Björkman-Burtscher; M Söderberg
Journal:  Br J Radiol       Date:  2013-09-18       Impact factor: 3.039

3.  Full Dose-Reduction Potential of Statistical Iterative Reconstruction for Head CT Protocols in a Predominantly Pediatric Population.

Authors:  A E Mirro; S L Brady; R A Kaufman
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-07       Impact factor: 3.825

4.  Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction.

Authors:  Joris M Niesten; Irene C van der Schaaf; Alan J Riordan; Hugo W A M de Jong; Alexander D Horsch; Daniel Eijspaart; Ewoud J Smit; Willem P T M Mali; Birgitta K Velthuis
Journal:  Eur Radiol       Date:  2013-10-15       Impact factor: 5.315

5.  Potential of combining iterative reconstruction with noise efficient detector design: aggressive dose reduction in head CT.

Authors:  H Brodoefel; B Bender; C Schabel; M Fenchel; U Ernemann; A Korn
Journal:  Br J Radiol       Date:  2015-04-01       Impact factor: 3.039

6.  Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography.

Authors:  Guo Zhong Chen; Long Jiang Zhang; U Joseph Schoepf; Julian L Wichmann; Cole M Milliken; Chang Sheng Zhou; Li Qi; Song Luo; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-01-31       Impact factor: 5.315

7.  Iterative reconstruction techniques for computed tomography Part 1: technical principles.

Authors:  Martin J Willemink; Pim A de Jong; Tim Leiner; Linda M de Heer; Rutger A J Nievelstein; Ricardo P J Budde; Arnold M R Schilham
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

8.  Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose.

Authors:  Kouhei Kamiya; Akira Kunimatsu; Harushi Mori; Jiro Sato; Masaaki Akahane; Takana Yamakawa; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2013-02-14       Impact factor: 2.374

9.  Improving acute stroke management with computed tomography perfusion: a review of imaging basics and applications.

Authors:  C D d'Esterre; Enrico Fainardi; R I Aviv; T Y Lee
Journal:  Transl Stroke Res       Date:  2012-05-24       Impact factor: 6.829

10.  Repeated head CT in the neurosurgical intensive care unit: feasibility of sinogram-affirmed iterative reconstruction-based ultra-low-dose CT for surveillance.

Authors:  I Corcuera-Solano; A H Doshi; A Noor; L N Tanenbaum
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-20       Impact factor: 3.825

View more