Low tube voltage and low contrast material volume cerebral CT angiography.

Song Luo1, Long Jiang Zhang, Felix G Meinel, Chang Sheng Zhou, Li Qi, Andrew D McQuiston, U Joseph Schoepf, Guang Ming Lu.   

Abstract

OBJECTIVES: To evaluate the image quality, radiation dose and diagnostic accuracy of low kVp and low contrast material volume cerebral CT angiography (CTA) in intracranial aneurysm detection.
METHODS: One hundred twenty patients were randomly divided into three groups (n = 40 for each): Group A, 70 ml iodinated contrast agent/120 kVp; group B, 30 ml/100 kVp; group C, 30 ml/80 kVp. The CT numbers, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Subjective image quality was evaluated. For patients undergoing DSA, diagnostic accuracy of CTA was calculated with DSA as reference standard and compared.
RESULTS: CT numbers of ICA and MCA were higher in groups B and C than in group A (P < 0.01). SNR and CNR in groups A and B were higher than in group C (both P < 0.05). There was no difference in subjective image quality among the three groups (P = 0.939). Diagnostic accuracy for aneurysm detection among these groups had no statistical difference (P = 1.00). Compared with group A, the radiation dose of groups B and C was decreased by 45% and 74%.
CONCLUSION: Cerebral CTA at 100 or 80 kVp using 30 ml contrast agent can obtain diagnostic image quality with a low radiation dose while maintaining the same diagnostic accuracy for aneurysm detection. KEY POINTS: • Cerebral CTA is feasible using 100/80 kVp and 30 ml contrast agent. • This approach obtains diagnostic image quality with 45-74% radiation dose reduction. • Diagnostic accuracy for intracranial aneurysm detection seems not to be compromised.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24792591     DOI: 10.1007/s00330-014-3184-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  33 in total

1.  Reduction of contrast material volume in 3D angiography of the brain using MDCT.

Authors:  Yoshitaka Tamura; Daisuke Utsunomiya; Takashi Sakamoto; Toshinori Hirai; Taiji Nishiharu; Joji Urata; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

2.  Comparison of different phantom designs for CT scanner automatic tube current modulation system tests.

Authors:  S Sookpeng; C J Martin; D J Gentle
Journal:  J Radiol Prot       Date:  2013-09-11       Impact factor: 1.394

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Initiatives focus on limiting radiation exposure to patients during CT scans.

Authors:  Denise M Goodman
Journal:  JAMA       Date:  2013-02-20       Impact factor: 56.272

5.  Dual-energy CT angiography in the evaluation of intracranial aneurysms: image quality, radiation dose, and comparison with 3D rotational digital subtraction angiography.

Authors:  Long-Jiang Zhang; Sheng-Yong Wu; Jing-Bo Niu; Zhuo-Li Zhang; Henry Z Wang; Yan-E Zhao; Xue Chai; Chang-Sheng Zhou; Guang-Ming Lu
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

Review 6.  Intracranial aneurysms in patients with subarachnoid hemorrhage: CT angiography as a primary examination tool for diagnosis--systematic review and meta-analysis.

Authors:  Henriëtte E Westerlaan; J M C van Dijk; M J van Dijk; Marijke C Jansen-van der Weide; Jan Cees de Groot; Rob J M Groen; Jan Jakob A Mooij; Matthijs Oudkerk
Journal:  Radiology       Date:  2010-10-08       Impact factor: 11.105

7.  Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography.

Authors:  Qi Li; Fajin Lv; Yongmei Li; Kewei Li; Tianyou Luo; Peng Xie
Journal:  Eur Radiol       Date:  2009-05-01       Impact factor: 5.315

8.  Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography.

Authors:  A M McKinney; C S Palmer; C L Truwit; A Karagulle; M Teksam
Journal:  AJNR Am J Neuroradiol       Date:  2007-12-07       Impact factor: 3.825

9.  Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate.

Authors:  Matthew S Davenport; Shokoufeh Khalatbari; Richard H Cohan; Jonathan R Dillman; James D Myles; James H Ellis
Journal:  Radiology       Date:  2013-04-11       Impact factor: 11.105

10.  CT angiography of the head-and-neck vessels acquired with low tube voltage, low iodine, and iterative image reconstruction: clinical evaluation of radiation dose and image quality.

Authors:  Wei-lan Zhang; Min Li; Bo Zhang; Hai-yang Geng; Yin-qiang Liang; Ke Xu; Song-bai Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

View more
  15 in total

1.  Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study.

Authors:  Xiao Kun Fang; Qian Qian Ni; U Joseph Schoepf; Chang Sheng Zhou; Guo Zhong Chen; Song Luo; Stephen R Fuller; Carlo N De Cecco; Long Jiang Zhang; Guang Ming Lu
Journal:  Eur Radiol       Date:  2016-02-06       Impact factor: 5.315

Review 2.  Contrast-induced nephropathy in CT: incidence, risk factors and strategies for prevention.

Authors:  Shu Min Tao; Julian L Wichmann; U Joseph Schoepf; Stephen R Fuller; Guang Ming Lu; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2015-12-18       Impact factor: 5.315

3.  Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium.

Authors:  Lu Zhao; Fengtan Li; Zewei Zhang; Zhang Zhang; Yingjian Jiang; Xinyu Wang; Jun Gu; Dong Li
Journal:  Eur Radiol       Date:  2018-04-13       Impact factor: 5.315

4.  Optimal scan timing for artery-vein separation at whole-brain CT angiography using a 320-row MDCT volume scanner.

Authors:  Takashi Shirasaka; Akio Hiwatashi; Koji Yamashita; Masatoshi Kondo; Hiroshi Hamasaki; Yamato Shimomiya; Yasuhiko Nakamura; Yoshinori Funama; Hiroshi Honda
Journal:  Br J Radiol       Date:  2016-12-20       Impact factor: 3.039

5.  Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Hideaki Yuki; Kenichiro Hirarta; Seitaro Oda; Masafumi Kidoh; Daisuke Utsunomiya; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2017-01-03       Impact factor: 2.804

6.  Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography.

Authors:  Guo Zhong Chen; Long Jiang Zhang; U Joseph Schoepf; Julian L Wichmann; Cole M Milliken; Chang Sheng Zhou; Li Qi; Song Luo; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-01-31       Impact factor: 5.315

7.  Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping.

Authors:  Vincent Dunet; Martine Bernasconi; Steven David Hajdu; Reto Antoine Meuli; Roy Thomas Daniel; Jean-Baptiste Zerlauth
Journal:  Neuroradiology       Date:  2017-07-27       Impact factor: 2.804

8.  Head and neck angiography at 70 kVp with a third-generation dual-source CT system in patients: comparison with 100 kVp.

Authors:  Yu Chen; Xiaobo Zhang; Huadan Xue; Yuanli Zhu; Yun Wang; Yumei Li; Zhuhua Zhang; Zhengyu Jin
Journal:  Neuroradiology       Date:  2017-08-24       Impact factor: 2.804

9.  Cerebral CTA with Low Tube Voltage and Low Contrast Material Volume for Detection of Intracranial Aneurysms.

Authors:  Q Q Ni; G Z Chen; U J Schoepf; M A J Klitsie; C N De Cecco; C S Zhou; S Luo; G M Lu; L J Zhang
Journal:  AJNR Am J Neuroradiol       Date:  2016-05-05       Impact factor: 3.825

10.  Comparison of Imaging Selection Criteria for Intra-Arterial Thrombectomy in Acute Ischemic Stroke with Advanced CT.

Authors:  Eung Yeop Kim; Dong Hoon Shin; Young Noh; Byeong Ho Goh; Yeong-Bae Lee
Journal:  Eur Radiol       Date:  2015-12-08       Impact factor: 5.315