Literature DB >> 15482993

Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas.

S Fenchel1, T R Fleiter, A J Aschoff, R van Gessel, H-J Brambs, E M Merkle.   

Abstract

The purpose of this study was to determine the influence of two different iodine concentrations of the non-ionic contrast agent, Iomeprol, on contrast enhancement in multislice CT (MSCT) of the pancreas. To achieve this MSCT of the pancreas was performed in 50 patients (mean age 57+/-14 years) with suspected or known pancreatic tumours. The patients were randomly assigned to group A (n=25 patients) or group B (n=25 patients). There were no statistically significant differences in age, height or weight between the patients of the two groups. The contrast agent, Iomeprol, was injected with iodine concentrations of 300 mg ml(-1) in group A (130 ml, injection rate 5 ml s(-1)) and 400 mg ml(-1) in group B (98 ml, injection rate 5 ml s(-1)). Arterial and portal venous phase contrast enhancement (HU) of the vessels, organs, and pancreatic masses were measured and a qualitative image assessment was performed by two independent readers. In the arterial phase, Iomeprol 400 led to a significantly greater enhancement in the aorta, superior mesenteric artery, coeliac trunk, pancreas, pancreatic carcinomas, kidneys, spleen and wall of the small intestine than Iomeprol 300. Portal venous phase enhancement was significantly greater in the pancreas, pancreatic carcinomas, wall of the small intestine and portal vein with Iomeprol 400. The two independent readers considered Iomeprol 400 superior over Iomeprol 300 concerning technical quality, contribution of the contrast agent to the diagnostic value, and evaluability of vessels in the arterial phase. No differences were found for tumour delineation and evaluability of infiltration of organs adjacent to the pancreas between the two iodine concentrations. In conclusion the higher iodine concentration leads to a higher arterial phase contrast enhancement of large and small arteries in MSCT of the pancreas and therefore improves the evaluability of vessels in the arterial phase.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15482993     DOI: 10.1259/bjr/19527646

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  10 in total

1.  Effect of varying contrast material iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64-section MDCT of patients with cirrhosis.

Authors:  A Guerrisi; D Marin; R C Nelson; G De Filippis; M Di Martino; H Barnhart; R Masciangelo; I Guerrisi; R Passariello; C Catalano
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

2.  Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

Authors:  Guangming Ma; Yong Yu; Haifeng Duan; Yuequn Dou; Yongjun Jia; Xirong Zhang; Chuangbo Yang; Xiaoxia Chen; Dong Han; Changyi Guo; Taiping He
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

3.  Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography.

Authors:  Masashi Nagamoto; Tatsuya Gomi; Hitoshi Terada; Shigehiko Terada; Eiichi Kohda
Journal:  Radiat Med       Date:  2006-12-25

4.  A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.

Authors:  Seung Chai Jung; Seung Hyup Kim; Jeong Yeon Cho
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

5.  Prospective study comparing two iodine concentrations for multidetector computed tomography of the pancreas.

Authors:  Y Liu; X Q Xu; X Z Lin; Q Song; K M Chen
Journal:  Radiol Med       Date:  2010-03-09       Impact factor: 3.469

6.  Pancreatic adenocarcinoma: analysis of the effect of various concentrations of contrast material.

Authors:  Yoshihiko Fukukura; Hiroyuki Hamada; Takuro Kamiyama; Tomohide Yoneyama; Koji Takumi; Masayuki Nakajo
Journal:  Radiat Med       Date:  2008-08-03

7.  CT angiography of the head-and-neck vessels acquired with low tube voltage, low iodine, and iterative image reconstruction: clinical evaluation of radiation dose and image quality.

Authors:  Wei-lan Zhang; Min Li; Bo Zhang; Hai-yang Geng; Yin-qiang Liang; Ke Xu; Song-bai Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

Review 8.  Multidetector computer tomography in the pancreatic adenocarcinoma assessment: an update.

Authors:  Vincenza Granata; Roberta Fusco; Orlando Catalano; Sergio Venanzio Setola; Elisabetta de Lutio di Castelguidone; Mauro Piccirillo; Raffaele Palaia; Roberto Grassi; Francesco Granata; Francesco Izzo; Antonella Petrillo
Journal:  Infect Agent Cancer       Date:  2016-11-15       Impact factor: 2.965

Review 9.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

10.  Effects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT.

Authors:  Makoto Sakane; Tonsok Kim; Masatoshi Hori; Hiromitsu Onishi; Atsushi Nakamoto; Takahiro Tsuboyama; Mitsuaki Tatsumi; Noriyuki Tomiyama
Journal:  Springerplus       Date:  2014-05-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.