Karl Martin Lehmann1, Michael Weyhrauch1, Monika Bjelopavlovic1, Herbert Scheller1, Henning Staedt2, Peter Ottl2,3, Peer W Kaemmerer4, Stefan Wentaschek1.
Abstract
BACKGROUND: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps.Entities:
Keywords: CAD/CAM; FPD; internal fit; marginal fit; zirconia
Year: 2021 PMID: 34069551 PMCID: PMC8161266 DOI: 10.3390/ma14102663
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Zirconia four-unit framework.
Figure 2CAM Systems. System (A) (VHF CAM 4-02 Impression), system (B) (Datron D5), system (C) (Cerec MCXL) and system (D) (Roland DWX-50).
Figure 3Measurement points at the marginal and internal surfaces of a restoration.
Performance of the CAD/CAM systems.
| System | Mean (µm) | SD | Min (µm) | Max (µm) |
|---|---|---|---|---|
|
| 84 | 43 | 0 | 285 |
|
| 113 | 65 | 0 | 433 |
|
| 132 | 71 | 5 | 579 |
|
| 101 | 67 | 10 | 427 |
Gap sizes of FPDs according to the tooth and the CAD/CAM system (µm).
| Tooth | (A/B/C/D) | (A/B/C/D) | (A/B/C/D) | (A/B/C/D) |
|---|---|---|---|---|
| Mean | SD | Min | Max | |
| 34 | 83/109/141/110 | 45/66/80/74 | 0/0/5/10 | 285/428/579/416 |
| 35 | 85/125/143/105 | 44/72/69/68 | 0/8/11/10 | 256/433/551/427 |
| 37 | 85/104/113/88 | 41/55/58/55 | 0/0/8/11 | 223/300/505/339 |
Repeated-measures one-way analysis of variance results.
| Tooth | (A/B/C/D) | (A/B/C/D) | (A/B/C/D) |
|---|---|---|---|
| 34 | 35 | 37 | |
| 34 | -/-/-/- | 0.107/<0.001/1.000/<0.001 | 0.125/<0.001/<0.001/<0.001 |
| 35 | -/-/-/- | 1.000/<0.001/1.000/<0.001 | |
| 37 | -/-/-/- |
Mean gap size with standard deviation, minimum and maximum, according to region (µm).
| Region | A | B | C | D |
|---|---|---|---|---|
| Marginal (Q) | 38/7/24/49 | 72/25/42/125 | 64/19/39/99 | 58/27/32/104 |
| Axial wall (R) | 76/24/44/117 | 94/40/53/167 | 141/29/95/226 | 75/25/39/135 |
| Occlusal area (S) | 132/20/89/165 | 178/29/138/250 | 159/27/105/195 | 182/37/134/269 |