Literature DB >> 18798783

An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles.

Paolo Vigolo1, Fulvio Fonzi.   

Abstract

PURPOSE: The purpose of this study was to assess in vitro the marginal fit of four-unit fixed partial dentures (FPDs) produced using three different computer aided design/computer aided manufacturing (CAD/CAM) all-ceramic systems before and after porcelain firing cycles and after glaze cycles.
MATERIALS AND METHODS: An acrylic resin model of a maxillary arch was fabricated. Teeth #6 and 9 were prepared; teeth #7 and 8 were absent. Forty-five four-unit zirconium-oxide-based ceramic FPDs were made following conventional impression and master cast techniques: 15 were made with the Everest system, 15 with the Procera system, and 15 with the Lava system. Marginal gaps along vertical planes were measured for each bridge before (Time 0) and after (Time 1) porcelain firing cycles and after glaze cycles (Time 2) using a total of 8 landmarks (4 for tooth #6 and 4 for tooth #9) by means of a microscope at a magnification of x50. MANOVA was performed to determine whether the 8 landmarks, jointly considered, differed between CAD/CAM systems and time phases. Two-way ANOVA was performed to investigate in detail, for each landmark, how gap measurements were related to CAD/CAM systems and time phases. Differences were considered to be significant at p < 0.05.
RESULTS: The mean values of the Everest system (microm) were: 63.37 (Time 0), 65.34 (Time 1), and 65.49 (Time 2); the mean values of the Lava system (microm) were: 46.30 (Time 0), 46.79 (Time 1), and 47.28 (Time 2); the mean values of the Procera system (microm) were: 61.08 (Time 0), 62.46 (Time 1), and 63.46 (Time 2). MANOVA revealed quantitative differences of the 8 landmarks, jointly considered, between the three CAD/CAM systems (p < 0.0001), but it did not reveal any quantitative differences among the three time phases (p > 0.4). Two-way ANOVA revealed that the Lava system produced gap measurements statistically smaller than the Everest and Procera systems (p < 0.0001 for each landmark).
CONCLUSIONS: Within the limitations of this study, it was concluded that the three zirconium-oxide-based ceramic CAD/CAM systems demonstrated a comparable and acceptable marginal fit; however, the Lava system produced gap measurements statistically smaller than the Everest and Procera systems. The porcelain firing cycles and the glaze cycles did not affect the marginal fit of the zirconium-oxide-based ceramic CAD/CAM systems.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18798783     DOI: 10.1111/j.1532-849X.2008.00366.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  19 in total

1.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

2.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

3.  Clinical performance and failures of zirconia-based fixed partial dentures: a review literature.

Authors:  Premwara Triwatana; Noppavan Nagaviroj; Chantana Tulapornchai
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

4.  The elements of life and medicines.

Authors:  Prinessa Chellan; Peter J Sadler
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-03-13       Impact factor: 4.226

5.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

6.  Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Woong-Chul Kim; Hae-Young Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

7.  Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations.

Authors:  Ki-Hong Lee; In-Sung Yeo; Benjamin M Wu; Jae-Ho Yang; Jung-Suk Han; Sung-Hun Kim; Yang-Jin Yi; Taek-Ka Kwon
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

8.  Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study.

Authors:  Giorgio Pompa; Stefano Di Carlo; Francesca De Angelis; Maria Paola Cristalli; Susanna Annibali
Journal:  Biomed Res Int       Date:  2015-10-21       Impact factor: 3.411

9.  Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems.

Authors:  Tae-Jin Song; Taek-Ka Kwon; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

10.  Clinical gap changes after porcelain firing cycles of zirconia fixed dentures.

Authors:  Bugurman Burcu Bugurman; Sebnem Begum Turker
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.