Literature DB >> 22864213

Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings.

Sven Rinke1, Daniel Fornefett, Nikolaus Gersdorff, Katharina Lange, Matthias Roediger.   

Abstract

This study evaluated the effect of different parameters on the marginal precision of CAD/CAM-fabricated zirconia copings. Specimens(n=60) were fabricated with two different scanners and two milling systems. The copings were evaluated with respect to their mean and average maximum marginal gaps. A two-way analysis of variance (ANOVA) (α=0.05) was used to evaluate the effect of different parameters (scanner, milling process) on marginal accuracy. The mean (averaged maximum) marginal gaps ranged from 57.9 (112.2 μm) to 71.0 (144.6 μm) in the "as machined" state. After manual adaptation, the respective values ranged from 54.6 (98.0 μm) to 59.9(107.7 μm). The system and manual adaptation variables were found both to have multiple significant effects on the marginal gap size and to have a complex interaction. Thus, synchronized/validated processing chains should be preferentially used to guarantee optimal fitting accuracy for CAD/CAM zirconia restorations.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22864213     DOI: 10.4012/dmj.2012-017

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  9 in total

1.  Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study.

Authors:  Matthias Rödiger; Arthur Heinitz; Ralf Bürgers; Sven Rinke
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

2.  Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study.

Authors:  Hüseyin Berkay Belgin; Ediz Kale; Tuncer Burak Özçelik; Burak Yilmaz
Journal:  Odontology       Date:  2021-10-19       Impact factor: 2.634

3.  Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Authors:  Francesco Ferrini; Gianpaolo Sannino; Carlo Chiola; Paolo Capparé; Giorgio Gastaldi; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2019-02-14       Impact factor: 3.390

Review 4.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

5.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

6.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

7.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

8.  Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings.

Authors:  Matthias Rödiger; Lea Schneider; Sven Rinke
Journal:  Biomed Res Int       Date:  2018-03-22       Impact factor: 3.411

9.  Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations.

Authors:  Roberto Padrós; Luís Giner; Mariano Herrero-Climent; Carlos Falcao-Costa; José-Vicente Ríos-Santos; Francisco Javier Gil
Journal:  Int J Environ Res Public Health       Date:  2020-06-15       Impact factor: 3.390

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.