Fit of single tooth zirconia copings: comparison between various manufacturing processes.

Charlotte Grenade1, Amélie Mainjot, Alain Vanheusden.   

Abstract

STATEMENT OF PROBLEM: Various CAD/CAM processes are commercially available to manufacture zirconia copings. Comparative data on their performance in terms of fit are needed.
PURPOSE: The purpose of this in vitro study was to compare the internal and marginal fit of single tooth zirconia copings manufactured with a CAD/CAM process (Procera; Nobel Biocare) and a mechanized manufacturing process (Ceramill; Amann Girrbach).
MATERIAL AND METHODS: Abutments (n=20) prepared in vivo for ceramic crowns served as a template for manufacturing both Procera and Ceramill zirconia copings. Copings were manufactured and cemented (Clearfil Esthetic Cement; Kuraray) on epoxy replicas of stone cast abutments. Specimens were sectioned. Nine measurements were performed for each coping. Over- and under-extended margins were evaluated. Comparisons between the 2 processes were performed with a generalized linear mixed model (α=.05).
RESULTS: Internal gap values between Procera and Ceramill groups were not significantly different (P=.13). The mean marginal gap (SD) for Procera copings (51(50) μm) was significantly smaller than for Ceramill (81(66) μm) (P<.005). The percentages of over- and under-extended margins were 43% and 57% for Procera respectively, and 71% and 29% for Ceramill.
CONCLUSIONS: Within the limitations of this in vitro study, the marginal fit of Procera copings was significantly better than that of Ceramill copings. Furthermore, Procera copings showed a smaller percentage of over-extended margins than did Ceramill copings.
Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21458650     DOI: 10.1016/S0022-3913(11)60040-1

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  26 in total

1.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

2.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

3.  Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

Authors:  Eswaran Bhaskaran; N S Azhagarasan; Saket Miglani; T Ilango; G Phani Krishna; B Gajapathi
Journal:  J Indian Prosthodont Soc       Date:  2013-05-03

4.  Evaluation of different approaches for using a laser scanner in digitization of dental impressions.

Authors:  Wan-Sun Lee; Woong-Chul Kim; Hae-Young Kim; Wook-Tae Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

5.  Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings.

Authors:  Syed Rashid Habib; Waleed Asiri; Mohammed Jameel Hefne
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

6.  Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study.

Authors:  Balaji N Rajan; Srinivasan Jayaraman; Baburajan Kandhasamy; Ilangkumaran Rajakumaran
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

7.  Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions.

Authors:  Tae-Gyung Kim; Sungtae Kim; Hyunmin Choi; Jae-Hoon Lee; Jae-Hong Kim; Hong-Seok Moon
Journal:  Biomed Res Int       Date:  2016-11-28       Impact factor: 3.411

8.  Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems.

Authors:  Seok-Joon Ha; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

9.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

10.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.