Literature DB >> 33437249

Influence of contemporary CAD-CAM milling systems on the fit and adaptation of partially stabilized Zirconia fixed partial dentures.

Khulud A Al-Aali1, Rana S Alhamdan2, Ahmed M Maawadh3, Fahim Vohra4, Tariq Abduljabbar5.   

Abstract

OBJECTIVE: To evaluate marginal fit and internal adaptation of three-unit Zr frameworks fabricated from four Zr CAD/CAM milling systems.
METHODS: Fixed partial denture models were replicated (40 stone models) using Polyvinyl Siloxane impression material (PVS) and type IV stone for Zr framework fabrication. FPDs were milled with four CAD/CAM systems, Group-II: LAVAL Zirconia milled by LAVA , Group-2: Vita In-Ceram YZ milled by Cerec®, Group-3: Zirconia milled by GM1000 and Group-4: Zirconia milled by DWX-50N. Twelve marginal gap measurements per framework were performed at pre-established points, with a metallurgical microscope (Zeiss, Germany) at 500X magnification. Eight measurements of cement space per section were performed for adaptation. Data was analyzed using ANOVA and Tukey post hoc test.
RESULTS: Zirconia FPD frameworks exhibited gaps ranging from 16 to 50.1 µm for marginal fit and 26.8 to 102.5 µm for internal adaptation. Group-3 [20.8 (8.3) µm & 50.3 (11.4) µm] and Group-4 [16.0 (4.0) µm & 40.2 (8.8) µm] specimens showed significantly lower marginal fit and internal adaptation gaps compared to Group-I [50.1 (13.4) µm & 100.5 (16.7) µm] and Group-2 [38.9 (8.2) µm & 102.5 (13.4) µm] specimens respectively.
CONCLUSIONS: Different CAD-CAM systems for fabrication of Zr FPD frameworks displayed a significant influence on marginal fit and internal adaptation of restorations. Copyright: © Pakistan Journal of Medical Sciences.

Entities:  

Keywords:  CAD-CAM; Fixed partial dentures; Internal adaptation; Marginal fit; Milling parameters

Year:  2021        PMID: 33437249      PMCID: PMC7794152          DOI: 10.12669/pjms.37.1.3490

Source DB:  PubMed          Journal:  Pak J Med Sci        ISSN: 1681-715X            Impact factor:   1.088


  19 in total

1.  Innovative method for the analysis of the internal 3D fitting accuracy of Cerec-3 crowns.

Authors:  G Bornemann; S Lemelson; R Luthardt
Journal:  Int J Comput Dent       Date:  2002 Apr-Jul       Impact factor: 1.883

2.  Relative translucency of six all-ceramic systems. Part I: core materials.

Authors:  Michael J Heffernan; Steven A Aquilino; Ana M Diaz-Arnold; Debra R Haselton; Clark M Stanford; Marcos A Vargas
Journal:  J Prosthet Dent       Date:  2002-07       Impact factor: 3.426

3.  Evaluation of subsurface damage in CAD/CAM machined dental ceramics.

Authors:  J Sindel; A Petschelt; F Grellner; C Dierken; P Greil
Journal:  J Mater Sci Mater Med       Date:  1998-05       Impact factor: 3.896

Review 4.  A review of dental CAD/CAM: current status and future perspectives from 20 years of experience.

Authors:  Takashi Miyazaki; Yasuhiro Hotta; Jun Kunii; Soichi Kuriyama; Yukimichi Tamaki
Journal:  Dent Mater J       Date:  2009-01       Impact factor: 2.102

5.  Five-axis laser milling system that realizes more accurate zirconia CAD/CAM crowns by direct milling from fully sintered blocks.

Authors:  Kazuo Ohkuma; Takashi Kameda; Kazuto Terada
Journal:  Dent Mater J       Date:  2018-09-14       Impact factor: 2.102

6.  The estimation of cement film thickness by an in vivo technique.

Authors:  J W McLean; J A von Fraunhofer
Journal:  Br Dent J       Date:  1971-08-03       Impact factor: 1.626

7.  Gingival and alveolar bone reaction to marginal fit of subgingival crown margins.

Authors:  S E Sorensen; I B Larsen; K D Jörgensen
Journal:  Scand J Dent Res       Date:  1986-04

8.  Clinical Outcomes and Predictors of Satisfaction in Patients with Improved Lithium Disilicate All-Ceramic Crowns.

Authors:  Mazin Saleh Samer; Qahtani Faraz; Sami Abdo Radman Al-Dubai; Fahim Vohra; Hadijah Abdullah; Tara Bai Taiyeb-Ali; Roslan Saub
Journal:  Med Princ Pract       Date:  2017-10-01       Impact factor: 1.927

Review 9.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08

10.  Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system.

Authors:  Ji Suk Shim; Jin Sook Lee; Jeong Yol Lee; Yeon Jo Choi; Sang Wan Shin; Jae Jun Ryu
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

View more
  2 in total

1.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

2.  Technical Accuracy of Dental Laboratories in the Quality and Shade Matching of Porcelain Fused to Metal Crowns: An In Vitro Study.

Authors:  Mohammed S Bin-Shuwaish; Yasser F AlFawaz; Hamad A AlGamaiah; Abdulaziz S AlSani; Ibrahim B Abobakr; Khaled M Alzahrani; Basil Almutairi; Esraa A Attar; Fahim Vohra; Tariq Abduljabbar
Journal:  Int J Environ Res Public Health       Date:  2021-03-08       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.