Literature DB >> 20557435

Fit of zirconia fixed partial denture: a systematic review.

J Abduo1, K Lyons, M Swain.   

Abstract

UNLABELLED: The aim of this study is to review all the published literature investigating the accuracy of fit of zirconia fixed partial dentures (FPD). A comprehensive electronic search was performed through PubMed (MEDLINE) using Boolean operators to combine the following key words: 'zirconia,''margin,''FPD,''internal,''fit,''gap,''fitting surface,''bridge' and 'fixed prosthesis.' The search was limited to articles written in English, published up to January 2010. In addition, a manual search was also conducted through articles and reference lists retrieved from the electronic search and peer-reviewed journals. A total of 115 articles were retrieved and only 15 met the specified inclusion criteria for the review. Twelve of these articles were in vitro and three of them were in vivo. The selected articles had assessed marginal and/or internal fit of zirconia FPDs against the effect of various parameters that were computer-aided design and computer-aided manufacturing (CAD/CAM) and CAM systems, post-sintered and pre-sintered milling, framework configuration, span length, veneer application and ageing.
CONCLUSIONS: CAD/CAM, post-sintered milling, straight configuration and shorter span frameworks provided superior results than CAM, pre-sintered milling, curved configuration and longer span frameworks. Veneering zirconia frameworks caused deterioration in fit, while ageing of zirconia had no implications on the fit. Further studies are needed to determine the clinical significance of the differences in the accuracy reported in this review.
© 2010 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20557435     DOI: 10.1111/j.1365-2842.2010.02113.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  38 in total

1.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

2.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

3.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

4.  A review of engineered zirconia surfaces in biomedical applications.

Authors:  Ling Yin; Yoshitaka Nakanishi; Abdur-Rasheed Alao; Xiao-Fei Song; Jaafar Abduo; Yu Zhang
Journal:  Procedia CIRP       Date:  2017-07-21

5.  Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study.

Authors:  Matthias Rödiger; Arthur Heinitz; Ralf Bürgers; Sven Rinke
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

6.  Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images.

Authors:  Letícia Queiroz Mauad; Paulo Victor Teixeira Doriguêtto; Daniela de Almeida; Karolina Aparecida Castilho Fardim; Alessiana Helena Machado; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

7.  Influence of time and hydration (ageing) on flexural strength of Yttrium stabilized Zirconia polycrystals (Y-TZP) fabricated with different CAD-CAM Systems.

Authors:  Khulud A Al-Aali; Saad Alresayes; Aasem M Alhenaki; Fahim Vohra; Tariq Abduljabbar
Journal:  Pak J Med Sci       Date:  2021 May-Jun       Impact factor: 1.088

8.  Evaluating the effect of repeated use of milling burs on surface roughness and adaptation of digitally fabricated ceramic veneers.

Authors:  Leila Payaminia; Naeime Moslemian; Shima Younespour; Soudabeh Koulivand; Marzieh Alikhasi
Journal:  Heliyon       Date:  2021-04-30

9.  Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Authors:  Nayana Paul; K N Raghavendra Swamy; M R Dhakshaini; Sanjukta Sowmya; M B Ravi
Journal:  J Clin Exp Dent       Date:  2020-01-01

10.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.