Literature DB >> 22372886

Comparison of the marginal adaptation of zirconium dioxide crowns in preparations with two different finish lines.

Raúl Euán1, Oscar Figueras-Álvarez, Josep Cabratosa-Termes, Magí Brufau-de Barberà, Susana Gomes-Azevedo.   

Abstract

PURPOSE: The purpose of this study was to evaluate the marginal adaptation of zirconium dioxide crowns in preparations with two different finish line configurations before and after porcelain firing cycles, after a glaze cycle, and after cementation.
MATERIALS AND METHODS: Twenty human molar teeth were prepared to receive full crowns; ten were prepared with a 90° round shoulder and another ten with a 45° chamfer finish line. Zirconium dioxide copings were fabricated using CAD/CAM technology (Lava™ system). They were then veneered with a low-fusing glass-ceramic (IPS e.max® Ceram). Finally, they were glazed and cemented with a resin-composite cement (RelyX™ Unicem, Aplicap™). Measurements for marginal adaptation using stereomicroscopy (40×) were performed at four stages: copings (S1), after porcelain firing cycles (S2), after glazing (S3), and after cementation (S4). One-way ANOVA was used to assess the influence of the finish line design on the marginal adaptation in each stage. Two-way ANOVA with repeated measurements was performed to assess the influence on the marginal adaptation of the porcelain firing cycles, glaze firing cycle, and cementation.
RESULTS: The measured marginal gap mean values for the shoulder group (μm) were: 50.13 (S1), 54.32 (S2), 55.12 (S3), and 59.83 (S4). The values for the chamfer group were: 63.56 (S1), 71.85 (S2), 74.12 (S3), and 76.97 (S4). When comparing marginal gaps between specimens with two different finish lines, differences were noticed at the four studied stages (p = 0.0165, p = 0.0027, p = 0.0009, and p = 0.0009, respectively). No differences were manifested in the marginal gap measurements of the shoulder group at the different stages of fabrication (p = 0.4335); however, in the chamfer group, differences were noticed between S1 and S3 (p = 0.0042).
CONCLUSIONS: Marginal adaptation was influenced by the finish line design. The firing cycles significantly affected the chamfer group; nevertheless, the marginal gap was within the range of clinical acceptability.
© 2012 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22372886     DOI: 10.1111/j.1532-849X.2011.00831.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

Review 2.  Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature.

Authors:  Kusai Baroudi; Shukran Nasser Ibraheem
Journal:  J Int Oral Health       Date:  2015-04

3.  The effect of various veneering techniques on the marginal fit of zirconia copings.

Authors:  Kianoosh Torabi; Mahroo Vojdani; Rashin Giti; Masumeh Taghva; Soheil Pardis
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  Comparison of Marginal Fit and Fracture Strength of a CAD/CAM Zirconia Crown with Two Preparation Designs.

Authors:  Hamid Jalali; Leyla Sadighpour; Ali Miri; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2015-12

5.  Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations.

Authors:  Mahya Hasanzade; Soudabeh Koulivand; Naeime Moslemian; Marzieh Alikhasi
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

Review 6.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

7.  Effect of Biologically Oriented Preparation Technique on the Stress Concentration of Endodontically Treated Upper Central Incisor Restored with Zirconia Crown: 3D-FEA.

Authors:  Luigi Giovanni Bernardo Sichi; Fernanda Zapater Pierre; Laura Viviana Calvache Arcila; Guilherme Schmitt de Andrade; João Paulo Mendes Tribst; Pietro Ausiello; Alessandro Espedito di Lauro; Alexandre Luiz Souto Borges
Journal:  Molecules       Date:  2021-10-10       Impact factor: 4.411

8.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

9.  The clinical challenge of achieving marginal adaptation in direct and indirect restorations.

Authors:  Karin Hermana Neppelenbroek
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

  9 in total