Literature DB >> 15819826

Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems.

Sven Reich1, Manfred Wichmann, Emeka Nkenke, Peter Proeschel.   

Abstract

In this study, the hypothesis was tested that the marginal and internal fit of CAD/CAM fabricated all-ceramic three-unit fixed partial dentures (FPDs) can be as good as in metal-ceramic FPDs. Twenty-four all-ceramic FPDs were fabricated and randomly subdivided into three equally sized groups. Eight frameworks were fabricated using the Digident CAD/CAM system (DIGI), another eight frameworks using the Cerec Inlab system (INLA). Vita Inceram Zirkonia blanks were used for both groups. In a third group frameworks were milled from yttrium-stabilized Zirconium blanks using the Lava system (LAVA). All frameworks were layered with ceramic veneering material. In addition, six three-unit metal-ceramic FPDs served as control group. All FPDs were evaluated using a replica technique with a light body silicone stabilized with a heavy body material. The replica samples were examined under microscope. The medians of marginal gaps were 75 microm for DIGI, 65 microm for LAVA and INLA and 54 microm for the conventional FPDs. Only the DIGI data differed significantly from those of the conventional FPDs. Within the limits of this study, the results suggest that the accuracy of CAD/CAM generated three-unit FPDs is satisfactory for clinical use.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15819826     DOI: 10.1111/j.1600-0722.2004.00197.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  50 in total

1.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

2.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

3.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

4.  Influence of CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes.

Authors:  A M Pabst; C Walter; L Grassmann; M Weyhrauch; D D Brüllmann; T Ziebart; H Scheller; K M Lehmann
Journal:  Clin Oral Investig       Date:  2013-08-31       Impact factor: 3.573

5.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

Review 6.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

7.  Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials.

Authors:  Joana Schönberger; Kurt-Jürgen Erdelt; Daniel Bäumer; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-02-04       Impact factor: 3.573

8.  Adaptation of all-ceramic fixed partial dentures.

Authors:  Márcia Borba; Paulo F Cesar; Jason A Griggs; Álvaro Della Bona
Journal:  Dent Mater       Date:  2011-09-13       Impact factor: 5.304

9.  Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

Authors:  Danush Ahrberg; Hans Christoph Lauer; Martin Ahrberg; Paul Weigl
Journal:  Clin Oral Investig       Date:  2015-06-14       Impact factor: 3.573

10.  Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions.

Authors:  Kazuhiko Ueda; Florian Beuer; Michael Stimmelmayr; Kurt Erdelt; Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2015-06-30       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.