Literature DB >> 22946875

An in vivo evaluation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns.

Leonello Biscaro1, Roberto Bonfiglioli, Massimo Soattin, Paolo Vigolo.   

Abstract

PURPOSE: The purpose of this study was to assess in vivo the marginal fit of single crowns produced using two CAD/CAM all-ceramic systems, in comparison to more traditional metal ceramic crowns.
MATERIALS AND METHODS: Thirty vital, caries-free, and previously untreated teeth were chosen in five patients who needed extraction for implant placement and therefore were included in this study. In the control group (C), 10 regular metal ceramic crowns with porcelain occlusal surfaces were fabricated. In the other two groups (Z and E), CAD/CAM technology was used for the fabrication of 20 zirconium-oxide-based ceramic single crowns with two systems. All zirconia crowns were cemented with glass-ionomer cement, always following the manufacturer's instructions. The same dentist carried out all clinical phases. The teeth were extracted 1 month later. Marginal gaps along vertical planes were measured for each crown, using a total of four landmarks for each tooth by means of a microscope at a magnification of 50×. On completion of microscopic evaluation, representative specimens from each group were prepared for ESEM evaluation. Mean and standard deviations of the four landmarks (mesial, distal, buccal, palatal) at each single crown were calculated for each group. Multivariate analysis of variance (MANOVA) was performed to determine whether the four landmarks, taken into consideration together, differed between groups. Two-way ANOVA was performed to study in detail, for each landmark, how the three systems used to produce the FPDs affected the gap measurements. Differences were considered to be significant at p < 0.05.
RESULTS: MANOVA revealed no quantitative differences of the four landmarks, when taken into consideration together, between the three groups (p < 0.0001). Two-way ANOVA, performed at each landmark, revealed no quantitative differences between the three groups (p < 0.0001 for each landmark).
CONCLUSIONS: Within the limitations of this study, it was concluded that the two zirconium-oxide-based ceramic CAD/CAM systems demonstrated a similar and acceptable marginal fit when compared to more traditional metal ceramic crowns.
© 2012 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22946875     DOI: 10.1111/j.1532-849X.2012.00907.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  An In-vitro Comparative Stereomicroscopic Analysis and Evaluation of Marginal Accuracy in Porcelain Fused to Metal Copings Fabricated in Two Different Finish Lines Using Variant Die Materials.

Authors:  Priya L Vaswani; Pronob K Sanyal; Siddharth Y Gosavi; Abhijeet R Kore
Journal:  J Clin Diagn Res       Date:  2017-01-01

2.  An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center.

Authors:  Avi Meirowitz; Yoli Bitterman; Sharon Levy; Eitan Mijiritsky; Eran Dolev
Journal:  BMC Oral Health       Date:  2019-06-13       Impact factor: 2.757

3.  Fatigue Failure Load of Molars with Thin-Walled Prosthetic Crowns Made of Various Materials: A 3D-FEA Theoretical Study.

Authors:  Noor Al Mortadi; Khaled Bataineh; Mohammad Al Janaideh
Journal:  Clin Cosmet Investig Dent       Date:  2020-12-18

4.  Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Authors:  Karl Martin Lehmann; Michael Weyhrauch; Monika Bjelopavlovic; Herbert Scheller; Henning Staedt; Peter Ottl; Peer W Kaemmerer; Stefan Wentaschek
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

5.  Comparative evaluation of bonding strength of computer aided machined ceramic, pressable ceramic, and milled metal implant abutment copings and effect of surface conditioning on bonding strength: An in vitro study.

Authors:  Sapna Rani; Mahesh Verma; Shubhra Gill; Rekha Gupta
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

6.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.