| Literature DB >> 27604229 |
Xun Chen1,2, Huamao Miao1,2, Rajeev Krishnan Naidu3, Xiaoying Wang4,5,6, Xingtao Zhou1,2.
Abstract
BACKGROUND: To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia.Entities:
Keywords: Implantable Collamer Lens; Pupil; Vault
Mesh:
Year: 2016 PMID: 27604229 PMCID: PMC5015244 DOI: 10.1186/s12886-016-0336-8
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Demographics of preoperative parameters
| Parameter | ICL V4 | ICL V4c |
|
|---|---|---|---|
|
| 38 | 39 | |
| Age, years | 28.66 ± 7.53(20 ~ 45) | 28.69 ± 6.44(20 ~ 45) | 0.98 |
| UDVA (Snellen lines) | 0.06 ± 0.04(0.01 ~ 0.15) | 0.07 ± 0.06(0.01 ~ 0.15) | 0.29 |
| CDVA (Snellen lines) | 0.94 ± 0.17(0.50 ~ 1.20) | 0.97 ± 0.15(0.7 ~ 1.20) | 0.39 |
| Refractive errors (D) | |||
| Spherical | −11.97 ± 3.46(−5.25 ~ −20.50) | −11.72 ± 3.58(−7.25 ~ −20.25) | 0.76 |
| Cylindrical | −1.34 ± 1.02(0 ~ −4.75) | −1.47 ± 1.10(−0.25 ~ −5.00) | 0.59 |
| Spherical equivalent | −12.64 ± 3.60(−5.75 ~ −21.38) | −12.46 ± 3.67(−7.75 ~ −22.00) | 0.83 |
| Keratometric value (D) | |||
| Flat K | 43.39 ± 1.73(38.3 ~ 46.7) | 43.12 ± 1.74(39.4 ~ 46.7) | 0.51 |
| Steep K | 44.60 ± 2.03(38.7 ~ 49.2) | 44.52 ± 1.87(41.2 ~ 49.0) | 0.86 |
| STS (mm) | |||
| Vertical | 12.36 ± 0.43(11.54 ~ 13.33) | 12.36 ± 0.68(10.67 ~ 13.75) | 0.98 |
| Horizontal | 11.76 ± 0.37(11.12 ~ 12.64) | 11.81 ± 0.62(10.31 ~ 13.39) | 0.68 |
| IOP (mm Hg) | 14.08 ± 2.38(8.8 ~ 19.1) | 15.20 ± 2.70(9.9 ~ 20.1) | 0.57 |
| Axial length (mm) | 28.24 ± 1.78(25.01 ~ 31.49) | 28.24 ± 1.78(25.42 ~ 32.19) | 0.99 |
| WTW diameter (mm) | 11.77 ± 0.34(11.2 ~ 12.5) | 11.85 ± 0.49(10.7 ~ 12.7) | 0.39 |
| ACD (mm) | 3.21 ± 0.23(2.83 ~ 3.70) | 3.18 ± 0.19(2.87 ~ 3.70) | 0.86 |
| CCT (mm) | 521.08 ± 35.70(467 ~ 603) | 515.51 ± 22.26(469 ~ 572) | 0.12 |
| ECD (cells/mm2) | 3254.18 ± 366.74(2331 ~ 3951) | 3270.18 ± 351.21(2374 ~ 4258) | 0.85 |
| Pupil size (mm) | 3.38 ± 0.74(2.09 ~ 4.48) | 3.14 ± 0.60(2.14 ~ 4.42) | 0.52 |
| ICL size (mm) | 12.36 ± 3.84(11.5 ~ 13.0) | 12.97 ± 0.47(12.1 ~ 13.7) | |
| ICL power (D) | −15.16 ± 7.22(−8.50 ~ −23.00) | −12.62 ± 2.92(−8.50 ~ −18.00) | |
Results are expressed as means ± standard deviation (range)
N number of eyes, UDVA uncorrected distance visual acuity, CDVA corrected distance visual acuity, D diopters, K keratometry, STS sulcus to sulcus, IOP intraocular pressure, WTW horizontal white-to-white diameter, ACD anterior chamber depth, CCT central corneal thickness, ECD corneal endothelial cell density, ICL implantable collamer lens
Postoperative vault and pupil size in eyes undergoing implantation of ICL V4 and ICL V4c
| Parameter | ICL V4 | ICL V4c | ||||
|---|---|---|---|---|---|---|
| Time course | 1 day | 1 week | 1 month | 1 day | 1 week | 1 month |
| Pupil size (mm) | ||||||
| Mean ± SD | 1.82 ± 0.66 | 3.50 ± 0.70 | 3.59 ± 0.68 | 2.43 ± 0.76 | 3.26 ± 0.45 | 3.31 ± 0.53 |
| Range | 1.02 ~ 3.63 | 2.01 ~ 5.54 | 2.31 ~ 5.52 | 1.21 ~ 3.95 | 2.11 ~ 4.75 | 2.23 ~ 4.84 |
| Vault (um) | ||||||
| Mean ± SD | 303.68 ± 185.11 | 517.89 ± 160.07 | 521.32 ± 155.72 | 316.67 ± 186.89 | 495.13 ± 180.84 | 510.77 ± 175.51 |
| Range | 0 ~ 680 | 270 ~ 920 | 290 ~ 980 | 0 ~ 690 | 150 ~ 850 | 190 ~ 860 |
ICL implantable collamer lens, SD standard deviation
Fig. 1Time course of the phakic IOL vaults in the two groups following implantation of ICL V4 and ICL V4c. (***P <0.001)
Fig. 2Time course of pupil size in the two groups following implantation of ICL V4 and ICL V4c. (***P <0.001)
Fig. 3Correlation of vault changes and pupil size changes in the ICL V4 and ICL V4c groups from 1 day postoperatively to 1 month postoperatively. (Pearman correlation coefficient; ICL V4: r = 0.585, P = 0.001, y = 159.0 x − 51.3; ICL V4c: r = 0.588, P <0.001, y = 118.5 x + 89.8, respectively)
Results of Stepwise Multiple Regression Analyses of ICL V4 and ICL V4c
| Variables | Partial Regression Coefficient | Standardized Partial Regression Coefficient |
|
|---|---|---|---|
| ICL V4 | |||
| Anterior chamber depth (mm) | 386.51 | 0.562 | <0.001 |
| Constant | −718.77 | 0.02 | |
|
| |||
| ICL V4c | |||
| Anterior chamber depth (mm) | 503.43 | 0.518 | 0.001 |
| Constant | −1075.64 | 0.02 | |
|
| |||
Fig. 4Correlation between anterior chamber depth and the central vault in the ICL V4 and ICL V4c groups (r = 0.562, P <0.001; r = 0.524, P = 0.001, respectively)
Fig. 5Correlation between white-to-white and the central vault in the ICL V4 and ICL V4c groups (r = 0.440, P = 0.006; r = 0.366, P = 0.022, respectively)
Fig. 6Correlation between horizontal sulcus to sulcus and the central vault in the ICL V4 and ICL V4c groups (r = 0.355, P = 0.029; r =0.365, P = 0.022, respectively)
Fig. 7Correlation between vertical sulcus to sulcus and the central vault in the ICL V4 and ICL V4c groups (r = 0.345, P = 0.034; r = 0.344, P = 0.032, respectively)