Literature DB >> 25149911

Dynamic vaulting changes in V4c versus V4 posterior chamber phakic lenses under differing lighting conditions.

Hun Lee1, Sung Yong Kang2, Kyoung Yul Seo1, Byunghoon Chung1, Jin Young Choi2, Kyu Seo Kim3, Tae-Im Kim4.   

Abstract

PURPOSE: To compare vaulting changes in eyes implanted with V4c and V4 implantable collamer lenses (ICLs) under differing lighting conditions.
DESIGN: Noninterventional, cross-sectional comparative observational case series.
METHODS: Fifty-six eyes of 38 patients implanted with V4c ICLs, and 54 eyes of 28 patients implanted with V4 ICLs were enrolled and analyzed. Anterior chamber depth, pupil size and postoperative vaulting were evaluated using a Visante optical coherence tomography system under photopic and mesopic conditions 1 month postoperatively. Refractive errors, keratometry values, axial lengths, intraocular pressures, anterior chamber volumes, and central corneal thicknesses were also recorded.
RESULTS: No significant differences were noted in anterior chamber depth between photopic and mesopic conditions in either group. Significant decreases in vaulting and pupil size were detected under photopic conditions in both groups. Moreover, vaulting changes in eyes implanted with V4c ICLs were significantly larger than those in eyes implanted with V4 ICLs.
CONCLUSIONS: V4c ICL vaulting decreased more prominently under photopic conditions than did V4 ICL vaulting. Therefore, postoperative vaulting under mesopic and photopic conditions should be considered when interpreting the vaulting of eyes implanted with V4c ICLs.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25149911     DOI: 10.1016/j.ajo.2014.08.020

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  14 in total

1.  Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology.

Authors:  Zhikun Yang; Lihui Meng; Xinyu Zhao; Youxin Chen; Yan Luo
Journal:  Front Med (Lausanne)       Date:  2022-06-09

2.  The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation.

Authors:  Zongli Hu; Chunlin Chen; Min Sun; Rongdi Yuan; Jian Ye
Journal:  J Ophthalmol       Date:  2020-07-21       Impact factor: 1.909

3.  Implantable collamer lens V4b and V4c for correction of high myopia.

Authors:  Vipul Bhandari; Smitha Karandikar; Jagdeesh K Reddy; Kirti Relekar
Journal:  J Curr Ophthalmol       Date:  2016-02-09

Review 4.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

5.  Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

Authors:  Xun Chen; Huamao Miao; Rajeev Krishnan Naidu; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-09-07       Impact factor: 2.209

6.  Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study.

Authors:  Felix Gonzalez-Lopez; Blas Mompean; Rafael Bilbao-Calabuig; Jorge Vila-Arteaga; Jaime Beltran; Julio Baviera
Journal:  Transl Vis Sci Technol       Date:  2018-05-01       Impact factor: 3.283

7.  Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes.

Authors:  Hun Lee; David Sung Yong Kang; Jin Young Choi; Byoung Jin Ha; Eung Kweon Kim; Kyoung Yul Seo; Tae-Im Kim
Journal:  BMC Ophthalmol       Date:  2018-07-06       Impact factor: 2.209

8.  Pupil Diameter Changes in High Myopes after Collamer Lens Implantation.

Authors:  Dan Li; Yabo Yang; Caipei Su; Houfa Yin; Xue Liu
Journal:  Optom Vis Sci       Date:  2015-12       Impact factor: 1.973

9.  Vault Changes Caused by Light-Induced Pupil Constriction and Accommodation in Eyes With an Implantable Collamer Lens.

Authors:  Sayaka Kato; Kimiya Shimizu; Akihito Igarashi
Journal:  Cornea       Date:  2019-02       Impact factor: 2.651

10.  Comparison of anterior chamber angle changes following phakic intraocular lens with and without a central hole implantation for moderate to high myopic eyes.

Authors:  Tian'an Zhou; Hui Jiang; Yang Wang; Chen Xie; Jianhua Xia; Ye Shen
Journal:  Medicine (Baltimore)       Date:  2020-12-04       Impact factor: 1.817

View more