Literature DB >> 22818905

Intraindividual comparison of visual performance after posterior chamber phakic intraocular lens with and without a central hole implantation for moderate to high myopia.

Kimiya Shimizu1, Kazutaka Kamiya, Akihito Igarashi, Tetsu Shiratani.   

Abstract

PURPOSE: To compare postoperative visual performance after implantable Collamer lenses with and without a central hole (Hole ICL and conventional ICL) are implanted to correct moderate to high myopia.
DESIGN: Prospective intraindividual comparative study. PATIENTS AND METHODS: This study evaluated 58 eyes of 29 patients with spherical equivalents of -7.55 ± 2.09 diopters (D) [mean ± standard deviation] who underwent Hole ICL implantation in one eye and conventional ICL implantation in the other eye by randomization assignment. Ocular higher-order aberrations (HOAs) and contrast sensitivity (CS) function were measured by Hartmann-Shack aberrometry and a contrast sensitivity unit before and 3 months after surgery, respectively. From the contrast sensitivity, the area under the log CS function was calculated.
RESULTS: For 4-mm and 6-mm pupils, the changes after Hole ICL implantation in coma-like aberrations, spherical-like aberrations, and total HOAs are similar to those after conventional ICL implantation (P > .05, Wilcoxon signed rank test). The postoperative area under the log CS function was significantly increased after Hole ICL implantation (P < .05), and was equivalent to that after conventional ICL implantation under photopic, mesopic, or mesopic with glare conditions. Subjective symptoms such as glare or halo were also essentially equivalent after Hole ICL and conventional ICL implantation.
CONCLUSIONS: A newly developed Hole ICL implantation appears to be equivalent in the induction of HOAs and CS function to conventional ICL implantation for the correction of moderate to high myopia, suggesting its viability as a surgical option for the treatment of such eyes, because it does not require additional peripheral iridotomies and may also reduce the risk of cataract formation.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22818905     DOI: 10.1016/j.ajo.2012.04.001

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  38 in total

1.  A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport.

Authors:  Kyu-Yeon Hwang; Sung A Lim; So-Hyang Chung
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

2.  Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

Authors:  T Kawamorita; K Shimizu; N Shoji
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

3.  Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens.

Authors:  Min Ji Park; Hye Min Jeon; Kyoung Heon Lee; Sang Youp Han
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

Review 4.  [Phakic intraocular lenses].

Authors:  T Kohnen; M Shajari
Journal:  Ophthalmologe       Date:  2016-06       Impact factor: 1.059

5.  Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

Authors:  Takushi Kawamorita; Kimiya Shimizu; Nobuyuki Shoji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-19       Impact factor: 3.117

6.  [Intraocular pressure after implantation of an ICL with aquaport : Development of intraocular pressure after implantation of an ICL (model V4c) with aquaport without iridotomy].

Authors:  B Repplinger; T Kohnen
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

7.  Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis.

Authors:  Hong-Ting Liu; Zhou Zhou; Wu-Qiang Luo; Wen-Jing He; Owhofasa Agbedia; Jiang-Xia Wang; Jian-Zhong Huang; Xin Gao; Min Kong; Min Li; Li Li
Journal:  Int J Ophthalmol       Date:  2018-04-18       Impact factor: 1.779

8.  Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation using the double-pass instrument.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Aya Saito; Akihito Igarashi; Hidenaga Kobashi
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

9.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22

10.  Posterior chamber phakic intraocular lens implantation after laser in situ keratomileusis.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Akihito Igarashi; Yoshihiro Kitazawa; Takashi Kojima; Tomoaki Nakamura; Kazuo Ichikawa; Sachiko Fukuoka; Kahoko Fujimoto
Journal:  Eye Vis (Lond)       Date:  2022-04-11
View more