Literature DB >> 20333528

Three-year follow-up of subjective vault following myopic implantable collamer lens implantation.

José F Alfonso1, Carlos Lisa, A Abdelhamid, Paulo Fernandes, Jorge Jorge, Robert Montés-Micó.   

Abstract

PURPOSE: To evaluate changes of subjective vault during a period of 36 months after implantation of phakic posterior chamber implantable collamer lens (ICL) for myopia correction.
METHODS: Nine hundred and sixty four myopic eyes of 531 patients, 353 females (66.5%) and 178 (33.5%) males, who received a Visian ICL (model V4, Staar Surgical Inc.) implantation were included in the study. Subjective vault classified in five levels (0, 1, 2, 3 and 4) was assessed at each of the follow-up visits by a trained ophthalmologist during a period of 36 months.
RESULTS: Mean vault decreased from 2.30 ± 0.87 immediately after surgery to 2.10 ± 0.92 at 12 months and to 2.06 ± 1.05 at 36 months. For patients presenting vault 2, 3, and 4 post-operatively, there was a decrease with time, with changes becoming statistically significant (p < 0.05) after the 3-month follow-up visit. The few eyes developing anterior subcapsular cataract (ASC) were older, had a tendency to vault 2 or lower post-operative, shallower anterior chamber depth and smaller ICL size. Eyes with acute increase in intraocular pressure (IOP) were significantly more myopic, had smaller white-to-white diameter and had larger photopic pupil diameters.
CONCLUSIONS: Decrease in subjective vault after ICL implantation became statistically significant after the third month postoperatively. Several patients and lens-related factors have been identified as potential predictors of ASC or acute increase in IOP. A tight follow-up during the critical post-operative period should be considered in those particular cases.

Entities:  

Mesh:

Year:  2010        PMID: 20333528     DOI: 10.1007/s00417-010-1322-0

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  26 in total

1.  Phakic posterior chamber intraocular lens for high myopia.

Authors:  Angel Pineda-Fernández; Jorge Jaramillo; José Vargas; Miguel Jaramillo; José Jaramillo; Alicia Galíndez
Journal:  J Cataract Refract Surg       Date:  2004-11       Impact factor: 3.351

2.  Myopic phakic STAAR collamer posterior chamber intraocular lenses for keratoconus.

Authors:  José F Alfonso; Ana Palacios; Robert Montés-Micó
Journal:  J Refract Surg       Date:  2008-11       Impact factor: 3.573

3.  Traumatic cataract and other adverse events with the implantable contact lens.

Authors:  Anna-Ulrika Sarikkola; H Nida Sen; Risto J Uusitalo; Leila Laatikainen
Journal:  J Cataract Refract Surg       Date:  2005-03       Impact factor: 3.351

4.  Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantation.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Takushi Kawamorita
Journal:  J Cataract Refract Surg       Date:  2009-09       Impact factor: 3.351

5.  Safety of posterior chamber phakic intraocular lenses for the correction of high myopia: anterior segment changes after posterior chamber phakic intraocular lens implantation.

Authors:  I Jiménez-Alfaro; J M Benítez del Castillo; J García-Feijoó; J G Gil de Bernabé; J M Serrano de La Iglesia
Journal:  Ophthalmology       Date:  2001-01       Impact factor: 12.079

6.  U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia.

Authors:  Donald R Sanders; John A Vukich; Kimberley Doney; Monica Gaston
Journal:  Ophthalmology       Date:  2003-02       Impact factor: 12.079

7.  Objective vs subjective vault measurement after myopic implantable collamer lens implantation.

Authors:  José F Alfonso; Carlos Lisa; Ana Palacios; Paulo Fernandes; José M González-Méijome; Robert Montés-Micó
Journal:  Am J Ophthalmol       Date:  2009-03-14       Impact factor: 5.258

8.  Implantable contact lens for moderate to high myopia: relationship of vaulting to cataract formation.

Authors:  Michel Gonvers; Chantal Bornet; Philippe Othenin-Girard
Journal:  J Cataract Refract Surg       Date:  2003-05       Impact factor: 3.351

9.  Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

Authors:  José F Alfonso; Carlos Lisa; Abdelhamid Abdelhamid; Robert Montés-Micó; Arancha Poo-López; Teresa Ferrer-Blasco
Journal:  J Cataract Refract Surg       Date:  2009-07       Impact factor: 3.351

10.  Ultrasound biomicroscopy for determining visian implantable contact lens length in phakic IOL implantation.

Authors:  Ki Hwan Choi; Song Ee Chung; Tae Young Chung; Eui Sang Chung
Journal:  J Refract Surg       Date:  2007-04       Impact factor: 3.573

View more
  23 in total

1.  Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

Authors:  Takushi Kawamorita; Hiroshi Uozato; Kimiya Shimizu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-11-01       Impact factor: 3.117

2.  Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCT.

Authors:  Jose F Alfonso; L Fernández-Vega; C Lisa; P Fernandes; J González-Meijome; R Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-28       Impact factor: 3.117

3.  Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia.

Authors:  Salem Almalki; Abdullah Abubaker; Nasser A Alsabaani; Deepak P Edward
Journal:  Int Ophthalmol       Date:  2015-08-12       Impact factor: 2.031

4.  Modulation transfer function of intraocular collamer lens with a central artificial hole.

Authors:  Hiroshi Uozato; Kimiya Shimizu; Takushi Kawamorita; Fumiko Ohmoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-01-13       Impact factor: 3.117

5.  Observing implantable collamer lens dislocation by panoramic ultrasound biomicroscopy.

Authors:  M Shi; J Kong; X Li; Q Yan; J Zhang
Journal:  Eye (Lond)       Date:  2015-01-23       Impact factor: 3.775

Review 6.  The posterior chamber phakic refractive lens (PRL): a review.

Authors:  R J Pérez-Cambrodí; D P Piñero; T Ferrer-Blasco; A Cerviño; R Brautaset
Journal:  Eye (Lond)       Date:  2012-12-07       Impact factor: 3.775

7.  A critical evaluation of longitudinal changes of astigmatism following implantation of toric implantable collamer lens (TICL): a comparison between treated and untreated cases over 4 years.

Authors:  Maja Bohac; Alma Biscevic; Ivan Gabric; Kresimir Gabric; Violeta Shijakova; Sudi Patel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-10-16       Impact factor: 3.117

Review 8.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

9.  Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

Authors:  J F Alfonso; C Lisa; L Fernández-Vega Cueto; P Fernandes; J M González-Méijome; R Montés Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-23       Impact factor: 3.117

10.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.