Literature DB >> 12511362

Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position.

Julián García-Feijoó1, Iñigo Jiménez Alfaro, Ricardo Cuiña-Sardiña, Carmen Méndez-Hernandez, José Manuel Benítez Del Castillo, Julián García-Sánchez.   

Abstract

OBJECTIVE: To better elucidate the in vivo position of the Collamer posterior chamber phakic intraocular lens (PCPIOL) and its relationship to the iris and the crystalline lens and to analyze possible variations over time.
DESIGN: Prospective observational case series. PARTICIPANTS: Eighteen eyes of nine patients were included. INTERVENTION: A Staar Collamer implantable PCPIOL was implanted for the correction of high myopia. MAIN OUTCOME MEASURES: The eyes were studied with a 50-MHz ultrasound biomicroscopy UBM 840. The exact PCPIOL position and the distances between it and the crystalline lens were measured at 3, 6, and 12 months after surgery.
RESULTS: There were no intraoperative complications. In 13 eyes (72.22%), contact between the PCPIOL and the crystalline lens was found at some time during follow-up. In 3 eyes (16.6%), central contact could be demonstrated. We also observed that the contact zone and its extension can vary over time. In 2 eyes, rotation of the lens was observed.
CONCLUSIONS: We found contact between the PCPIOL and the crystalline lens in a high percentage of cases. There was also mobility of the lens in the posterior chamber, especially in the anteroposterior plane, and, as a consequence, both the contact zone and its extension would vary over time.

Entities:  

Mesh:

Year:  2003        PMID: 12511362     DOI: 10.1016/s0161-6420(02)01449-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  12 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

2.  Ultrasonography of the Anterior Segment.

Authors:  Martin Heur; Bennie H Jeng
Journal:  Ultrasound Clin       Date:  2008-04-01

Review 3.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 4.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

5.  Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology.

Authors:  Zhikun Yang; Lihui Meng; Xinyu Zhao; Youxin Chen; Yan Luo
Journal:  Front Med (Lausanne)       Date:  2022-06-09

6.  Comparison of clear lens extraction and collamer lens implantation in high myopia.

Authors:  Ahmed M Emarah; Mostafa A El-Helw; Hazem M Yassin
Journal:  Clin Ophthalmol       Date:  2010-05-14

7.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

8.  Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

Authors:  Xun Chen; Huamao Miao; Rajeev Krishnan Naidu; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-09-07       Impact factor: 2.209

9.  Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia: A cohort study.

Authors:  Ying Tian; Hai-Bo Jiang; Jian Jiang; Dan Wen; Xiao-Bo Xia; Wei-Tao Song
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

10.  Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study.

Authors:  Felix Gonzalez-Lopez; Blas Mompean; Rafael Bilbao-Calabuig; Jorge Vila-Arteaga; Jaime Beltran; Julio Baviera
Journal:  Transl Vis Sci Technol       Date:  2018-05-01       Impact factor: 3.283

View more