Literature DB >> 21978592

Ultrasound biomicroscopy of anterior segment accommodative changes with posterior chamber phakic intraocular lens in high myopia.

Chixin Du1, Jianhua Wang, Xiaoyu Wang, Ying Dong, Yangshun Gu, Ye Shen.   

Abstract

PURPOSE: To investigate changes in anterior chamber depth (ACD) and the distance between the Visian implantable Collamer lens (ICL) and the crystalline lens during pharmacologic accommodation in high myopia.
DESIGN: Prospective, comparative case series. PARTICIPANTS: Thirty-three phakic eyes of 18 high myopic patients (range, -8.63 to -23.86 diopters) with a mean age of 29 years (range, 20-44 years) were examined at least 1 year after ICL implantation.
METHODS: Ultrasound biomicroscopy was used to measure distance changes between the corneal endothelium, the ICL, and the crystalline lens after inducing pharmacologic accommodation with topical pilocarpine in 1 eye. The contralateral eye served as the control. MAIN OUTCOME MEASURES: Mean changes of ACD measured from the posterior corneal surface to the crystalline lens (ACD-L), from the posterior corneal surface to the anterior surface of the ICL (ACD-ICL), and the distance between the ICL and the crystalline lens (ICL-L) at the central and peripheral regions of the eye.
RESULTS: For each eye, the ICL was in contact with the iris, but it was never in contact with the crystalline lens. At baseline, the mean distance between the ICL and the crystalline lens was 0.609 ± 0.165 mm at the central horizontal meridian, 0.588 ± 0.157 mm at the central vertical meridian, 0.281 ± 0.106 mm at the peripheral temporal sulcus, and 0.290 ± 0.098 mm at the peripheral nasal sulcus. After instillation of pilocarpine, a significant decrease in ICL-L was accompanied by a significant reduction in ACD-L and an increase in ACD-ICL (P<0.01). There were no significant changes in the control eyes (P>0.05). The central ICL-L reduction in the study group was significantly larger than that in the control group (P<0.01), but the peripheral ICL-L changes in the study group were not significantly different from those in the controls (P>0.05).
CONCLUSIONS: During pharmacologic accommodation, the ICL and the crystalline lens came closer as the ICL was pushed backward by the iris as a result of pupillary constriction. Simultaneously, the anterior surface of the crystalline lens became more convex and moved forward. Reduction of the distances at peripheral sulci was not as obvious as at the center. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21978592     DOI: 10.1016/j.ophtha.2011.07.001

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Changes in Accommodative and Binocular Function following Phakic Intraocular Lens for High and Low-to-Moderate Myopia.

Authors:  Esther López-Artero; Francisco Poyales; Nuria Garzón; Alicia Matamoros; Alba Sáez; Ying Zhou; María García-Montero
Journal:  Int J Environ Res Public Health       Date:  2022-05-31       Impact factor: 4.614

2.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

3.  Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

Authors:  Xun Chen; Huamao Miao; Rajeev Krishnan Naidu; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-09-07       Impact factor: 2.209

4.  Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes.

Authors:  Hun Lee; David Sung Yong Kang; Jin Young Choi; Byoung Jin Ha; Eung Kweon Kim; Kyoung Yul Seo; Tae-Im Kim
Journal:  BMC Ophthalmol       Date:  2018-07-06       Impact factor: 2.209

5.  A systematic review about the impact of phakic intraocular lenses on accommodation.

Authors:  Carlos J Hernández-Rodríguez; David P Piñero
Journal:  J Optom       Date:  2020-01-11

6.  In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy.

Authors:  Ahmed Mohamed Kamal Elshafei; Mahmoud Mohamed Genaidy; Hossam Mohamed Moharram
Journal:  J Ophthalmol       Date:  2016-09-08       Impact factor: 1.909

7.  Comparison of anterior chamber angle changes following phakic intraocular lens with and without a central hole implantation for moderate to high myopic eyes.

Authors:  Tian'an Zhou; Hui Jiang; Yang Wang; Chen Xie; Jianhua Xia; Ye Shen
Journal:  Medicine (Baltimore)       Date:  2020-12-04       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.