Literature DB >> 17455831

Ultrasound biomicroscopy for determining visian implantable contact lens length in phakic IOL implantation.

Ki Hwan Choi1, Song Ee Chung, Tae Young Chung, Eui Sang Chung.   

Abstract

PURPOSE: To assess the efficacy of the ultrasound biomicroscopic (UBM) method in estimating the sulcus-to-sulcus horizontal diameter for Visian Implantable Contact Lens (ICL, model V4) length determination to obtain optimal ICL vault.
METHODS: The results of postoperative ICL vaults in 30 eyes of 18 patients were retrospectively analyzed. In 17 eyes, ICL length was determined using the conventional method, and in 13 eyes, ICL length was determined using the UBM method. The UBM method was carried out by measuring the sulcus to limbus distance on each side by 50 MHz UBM and adding the white-to-white diameter by caliper or Orbscan. The ICL vaults were measured using the UBM method at 1 and 6 months postoperatively and the results were compared between the two groups. Ideal ICL vault was defined as vault between 250 and 750 microm. The relation between the ICL vault, footplate location, and ICL power was also investigated.
RESULTS: In the UBM method group, ICL vault was within the ideal range in all 13 (100%) eyes at 1 and 6 months postoperatively, whereas in the conventional method group, 10 (58.8%) eyes showed ideal vault at 1 month postoperatively (P = .01) and 9 (52.9%) eyes showed ideal vault at 6 months postoperatively (P < .01). The ideal ICL footplate location was achieved in the ciliary sulcus in 11 (84.6%) eyes of the UBM method group and 10 (64.7%) eyes of the conventional method group. However, the differences between the two groups were not statistically significant. The ICL vault was not significantly affected by the ICL power.
CONCLUSIONS: Implantable Contact Lens length determined by the UBM method achieved significantly more ideal ICL vault than that of the conventional white-to-white method. The UBM method is superior to the conventional method in terms of predicting the sulcus-to-sulcus horizontal diameter for ICL length determination.

Entities:  

Mesh:

Year:  2007        PMID: 17455831     DOI: 10.3928/1081-597X-20070401-08

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  25 in total

1.  Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCT.

Authors:  Jose F Alfonso; L Fernández-Vega; C Lisa; P Fernandes; J González-Meijome; R Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-28       Impact factor: 3.117

2.  Three-year follow-up of subjective vault following myopic implantable collamer lens implantation.

Authors:  José F Alfonso; Carlos Lisa; A Abdelhamid; Paulo Fernandes; Jorge Jorge; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

3.  Observing implantable collamer lens dislocation by panoramic ultrasound biomicroscopy.

Authors:  M Shi; J Kong; X Li; Q Yan; J Zhang
Journal:  Eye (Lond)       Date:  2015-01-23       Impact factor: 3.775

4.  Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism.

Authors:  Xun-Lun Sheng; Wei-Ning Rong; Qin Jia; Ya-Ni Liu; Wen-Juan Zhuang; Qing Gu; Yan Sun; Bo Pan; De-Jun Zhu
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

Review 5.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

6.  Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology.

Authors:  Zhikun Yang; Lihui Meng; Xinyu Zhao; Youxin Chen; Yan Luo
Journal:  Front Med (Lausanne)       Date:  2022-06-09

7.  Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter.

Authors:  Arvind Venkataraman; Sapna K Mardi; Sarita Pillai
Journal:  Indian J Ophthalmol       Date:  2010 May-Jun       Impact factor: 1.848

8.  Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Ronald H Silverman; Mark J Rondeau; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-02       Impact factor: 3.573

9.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

10.  Long-term refractive outcomes of posterior chamber phakic (spheric and toric implantable collamer lens) intraocular lens implantation.

Authors:  Arturo Gomez-Bastar; Martha Jaimes; Enrique O Graue-Hernández; Tito Ramirez-Luquin; Arturo Ramirez-Miranda; Alejandro Navas
Journal:  Int Ophthalmol       Date:  2013-10-11       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.