Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study.

Mohamed Nagy Elmohamady1, Walid Abdelghaffar2.   

Abstract

INTRODUCTION: The objective of this study was to evaluate the changes of the anterior chamber (AC) of the eye after implantable Collamer lens (ICL) implantation in high myopia by using the Pentacam.
METHODS: The prospective study included 34 high myopic patients (34 eyes). All patients were treated with Visian implantable Collamer lens (ICL) (Staar Surgical Co.) implantation. The Pentacam (Oculus) was used for all cases preoperatively and 1, 3 and 6 months postoperatively. AC angle (ACA), AC volume (ACV), central AC depth (CACD), ICL vault, central corneal thickness (CCT), pupil diameter (PD), K readings and intraocular pressure (IOP) were recorded.
RESULTS: Our study included 34 eyes of 34 patients, 20 females (59%) and 14 males (41%). Mean ACA was 36.93° ± 4.75° preoperatively, 25.17° ± 5.64° and 25.23° ± 6.05° 1 and 3 months postoperatively (p < 0.001). Mean ACV was 191.24 ± 11.18 mm3 preoperatively, 141.53 ± 16.77 and 142.11 ± 15.89 mm3 1 and 3 months postoperatively (p < 0.001). Mean CACD was 3.59 ± 0.17 mm preoperatively, 2.83 ± 0.24 mm and 2.96 ± 0.25 mm 1 and 3 months postoperatively (p < 0.001). The ICL vault decreased from 0.556 ± 0.033 mm 1 month postoperatively to 0.431 ± 0.056 mm 3 months postoperatively (p < 0.001). There were no statistically significant differences for any of the AC parameters among measurements taken 3, 6 and 12 months postoperatively. There were no statistically significant differences between preoperative and any postoperative measurements of CCT, PD and K readings.
CONCLUSIONS: ICL implantation for correction of high myopia leads to significant changes in the anterior chamber angle, volume and depth and insignificant changes in the pupil diameter, CCT and K readings.

Entities:  

Keywords:  Anterior chamber; Collamer, myopia; ICL; Pentacam

Year:  2017        PMID: 28933042      PMCID: PMC5693826          DOI: 10.1007/s40123-017-0109-3

Source DB:  PubMed          Journal:  Ophthalmol Ther


Introduction

The Visian Implantable Collamer Lens (ICL, STAAR Surgical, Nidau, Switzerland), a posterior chamber phakic intraocular lens (IOL), has been widely used and accepted for the correction of high myopia [1]. It has been reported to be a safe, effective and reversible approach but patients must be aware of possible complications, such as lens opacification, endothelial cell loss, increased intraocular pressure (IOP), inflammation and others [2, 3]. The anterior segment parameters are vital to choose the suitable refractive surgery. Central anterior chamber depth (CACD) and white to white (WTW) are important parameters for evaluating eligibility for ICL surgery and selecting the proper size of ICL [4]. A CACD value less than 2.80 mm is a contraindication to ICL surgery. The central vault, the distance between the back surface of the ICL and the front surface of the lens, is of value for estimating the safety of surgery postoperatively. An excessive vault may lead to glaucoma, and an insufficient vault increases the risk of anterior subcapsular cataracts [5]. Hence, an accurate and objective CACD and central vault assessment are both of great value for successful ICL surgery. The Pentacam generates a three-dimensional virtual model of the anterior segment in about 2 s. Software allows evaluation and quantification of anterior segment parameters such as the central anterior chamber depth (CACD), anterior chamber volume (ACV), pupil diameter (PD) and anterior chamber angle (ACA) of cross-section photographs from 0° to 360° [6]. Previous studies have been done to evaluate the safety and efficacy of ICL as a refractive treatment [1, 2, 7], to compare different methods of anterior segment imaging postoperatively [8] and to detect changes in anterior segment parameters after surgery [9]. However, none of these studies compared the pre- and postoperative anterior segment parameters using the Pentacam. The aim of our work is to evaluate changes of the anterior chamber (AC) of the eye after ICL implantation in high myopia using the Pentacam.

Methods

Thirty-four eyes of 34 patients (20 females, 14 males) who underwent ICL implantation for correction of high myopia at the Ophthalmology Department of Benha University Hospital between January 2015 and March 2016 were included. Patients with unrealistic expectations; anterior chamber depth less than 2.80 mm; IOP greater than 20 mmHg; a history of ocular surgery or trauma, cataract, glaucoma, diabetes mellitus, other ocular or systemic autoimmune diseases; and age less than 18 years were excluded from the study. The study was agreed upon by the research ethics committee of the Benha Faculty of Medicine. Informed consent was signed by all participants as per the Declaration of Helsinki.

Clinical Evaluation

We did a full ophthalmic examination for all subjects before the operation and 1, 3, 6 and 12 months postoperatively. The examinations included uncorrected and corrected distance visual acuity (UDVA and CDVA) according to the Snellen chart, manifest and cycloplegic refractions, slit-lamp bio-microscopy, fundus examinations and intraocular pressure.

Imaging

Imaging of the anterior segment preoperatively and 1, 3, 6 and 12 months after surgery using a rotating Scheimpflug camera (Pentacam version 1.20, Oculus, Germany) was carried out by the same observer and under scotopic conditions, with the patient’s chin placed on the chin rest and the forehead against the forehead strap. The patient was asked to fixate on the fixation target. Once alignment was perfect, 25 Scheimpflug images were automatically recorded within 2 s. Image quality was checked using the quality factor value for each eye. The AC angle (ACA) was measured superiorly, inferiorly, nasally and temporally, and then a mean ACA was calculated; the AC volume (ACV), central AC depth (CACD) and peripheral AC depth (PACD) were measured 4 mm from the center superiorly, inferiorly, nasally and temporally. Then, a mean PACD was calculated, and central corneal thickness (CCT), pupil diameter (PD) and K readings were recorded. The central vault of the ICL was measured 1, 3, 6 and 12 months after surgery using the image analysis program accompanying the device.

Implantable Collamer Lens Calculation

The ICL is 6.0 mm wide, and four sizes are available (11.5, 12.0, 12.5 and 13.0 mm in from −3.00 to −23.00 DS). Calculations of ICL power and size were done by the manufacturer. A modified vertex formula was used in power calculations. The variables in the formula are preoperative manifest and cycloplegic refractions, K readings, CCT and central ACD. The size of the ICL was determined by the STAAR sizing formula based on the WTW and CACD obtained by the Pentacam. For CACD of 2.80–3.00 mm, ICL length = WTW + 0.2–0.4 mm; for CACD of 3.00–3.50 mm, ICL length = WTW + 0.4–0.6 mm; for CACD of 3.50–3.70 mm, ICL length = WTW + 0.6–0.8 mm.

Surgical Procedure

Two YAG peripheral iridectomies were done at two different sites 2 weeks before surgery. Mydriatic agents were instilled four times at 10-min intervals before surgery. After topical anesthesia, a 3-mm temporal corneal incision was created. Viscoelastic material was injected in the AC. An injector cartridge (STAAR Surgical) was used to insert the ICL V4 without hole. The four footplates of the ICL were placed on the ciliary sulcus along the 180° axis. Viscoelastic material was completely removed using buffered salt solution. No astigmatic keratotomy or limbal relaxing incision was made. Postoperatively, tobramycin 0.3%-dexamethasone 0.1% (Tobradex) and moxifloxacin 0.5% (Vigamox) eye drops were administered topically three times daily for 2 weeks.

Statistical Analysis

Statistical analysis was done using SPSS version 20.0 (SPSS Inc., IBM, USA), and the results are expressed as mean ±  standard deviation (SD). The Kolmogorov-Smirnov test was employed to assure the normal distribution of the data. Comparison between pre- and postoperative measurements was done using independent t tests. A p value ≤0.05 was considered statistically significant. Spearman’s rho test was used to measure the strength of association between variables.

Results

This study included 34 eyes of 34 patients, 20 females (59%) and 8 males (41%). Mean age was 24.76 ± 5.14 (range, 19–37) years. Mean spherical equivalent (SE) of refractive error was −16.91 ± 2.37 D before surgery. One month after surgery, SE was −0.46 ± 0.37 D, and 3 months postoperatively SE became −0.51 ± 0.32 D (p = 0.553) (Table 1). No intra- or postoperative complications occurred except for increased IOP (>21 mmHg) in five eyes, which was managed by medical treatment with no need for surgical intervention.
Table 1

Patient demographics: selected pre- and postoperative characteristics

Gender

20 females (59%)

14 males (41%)

Age in years24.76 ± 5.14
Preoperative SE (D)−16.91 ± 2.37
1 month postoperatively SE (D)−0.46 ± 0.37

t = 0.596

p = 0.553

3 months postoperatively SE (D)−0.51 ± 0.32
6 months postoperatively SE (D)−0.55 ± 0.22
12 months postoperatively SE (D)−0.53 ± 0.28

Data are mean ± SD of 34 eyes of 20 patients preoperatively, 1, 3, 6 and 12 months after ICL implantation

SE spherical equivalent

Patient demographics: selected pre- and postoperative characteristics 20 females (59%) 14 males (41%) t = 0.596 p = 0.553 Data are mean ± SD of 34 eyes of 20 patients preoperatively, 1, 3, 6 and 12 months after ICL implantation SE spherical equivalent One month after surgery, ACV, ACA, CACD and PACD decreased significantly (p < 0.001). On the other hand, PD, CCT, keratometric values (K1 and K2) and IOP showed insignificant change with p values of 0.062 (PD was near to significance), 0.436, 0.145, 0.477 and 0.207, respectively, as shown in Table 2.
Table 2

Changes in anterior chamber parameters 1 month after ICL implantation

ParametersPreoperative1 Month postoperative3 Months postoperative6 Months postoperative12 Months postoperative
ACV (mm3)191.24 ± 11.18141.53 ± 16.77*142.11 ± 15.89*142.05 ± 14.76*142.07 ± 16.62*
ACA (°)36.93 ± 4.7525.17 ± 5.64*25.23 ± 6.05*25.30 ± 5.14*25.32 ± 7.24*
CACD (mm)3.59 ± 0.172.83 ± 0.24*2.96 ± 0.25*ǂ 2.94 ± 0.36*ǂ 2.95 ± 0.31*ǂ
PACD (mm)2.78 ± 0.212.13 ± 0.19*2.19 ± 0.13*2.12 ± 0.17*2.15 ± 0.20*
PD (mm)5.11 ± 0.564.77 ± 0.884.79 ± 0.904.75 ± 1.044.82 ± 1.17
CCT (μm)500.39 ± 19.71504.16 ± 20.12501.16 ± 19.52503.06 ± 22.14502.06 ± 20.86
K1 (D)43.28 ± 1.1142.89 ± 1.0742.96 ± 1.1542.88 ± 1.3142.74 ± 1.39
K2 (D)44.65 ± 1.3444.42 ± 1.3144.35 ± 1.2844.58 ± 1.4044.47 ± 1.44
IOP (mmHg)11.33 ± 2.4112.19 ± 3.1112.12 ± 2.9212.69 ± 2.6412.43 ± 3.57
Vault (mm)0.556 ± 0.0330.431 ± 0.056 ǂ0.429 ± 0.049 ǂ0.426 ± 0.064 ǂ

Data are mean ± SD of 34 eyes preoperatively, 1, 3, 6 and 12 months after ICL implantation

ACV anterior chamber volume, ACA anterior chamber angle, CACD central anterior chamber depth, PACD peripheral anterior chamber depth, PD pupil diameter, CCT central corneal thickness, IOP intraocular pressure

* Statistically significant difference from preoperative value, ǂ statistically significant difference from 1 month postoperative value

Changes in anterior chamber parameters 1 month after ICL implantation Data are mean ± SD of 34 eyes preoperatively, 1, 3, 6 and 12 months after ICL implantation ACV anterior chamber volume, ACA anterior chamber angle, CACD central anterior chamber depth, PACD peripheral anterior chamber depth, PD pupil diameter, CCT central corneal thickness, IOP intraocular pressure * Statistically significant difference from preoperative value, ǂ statistically significant difference from 1 month postoperative value Spearman’s rho test was used to measure the correlation between the central ICL vault and CACD at 1 month postoperatively; we found a statistically significant negative correlation (Spearman's correlation coefficient r = −0.8224, p < 0.001). We also found a statistically significant positive correlation between the central ICL vault and PD at 1 month postoperatively (Spearman's correlation coefficient r = 0.9429, p < 0.001). At the 3-month visit, the ACV, ACA, CACD and PACD had decreased significantly from the preoperative values (p < 0.001), while PD, CCT, keratometric values (K1 and K2) and IOP showed insignificant changes with p values of 0.083, 0.872, 0.274, 0.349 and 0.228, respectively (Table 2). There were no statistically significant changes in AC parameters between 1 and 3 months after ICL implantation except for the ICL vault, which decreased from 0.556 ± 0.033 mm 1 month post-surgery to 0.431 ± 0.056 mm 3 months postoperatively (p < 0.0001), and CACD, which increased from 2.83 ± 0.24 mm 1 to 2.96 ± 0.25 3 months postoperatively with p = 0.0323 (Table 2). We found no statistically significant changes in AC parameters among the 3-, 6- and 12-month results after ICL implantation as all p values were >0.05 (Table 2).

Discussion

The implantation of ICL has been shown to be an effective surgical treatment for the correction of refractive errors, offering good optical quality. With expanding use of ICLs worldwide, several studies addressing their efficacy and safety have been done and are still of current interest [1, 2, 6, 10–13]. Our study aimed to evaluate AC changes after ICL implantation using the Pentacam. Our results pointed to significant changes in ACA, ACV, CACD and PACD 1, 3, 6 and 12 months after surgery as compared to the preoperative parameters. On the other hand, we found insignificant changes in CCT, K readings, PD and IOP. We found that ACA decreased by 31.8%, 31.6%, 31.5% and 31.4% at 1, 3, 6 and 12 months postoperatively, respectively. ACA changed from 36.93° ± 4.75° preoperatively to 25.17° ± 5.61° 1 month postoperatively to 25.23° ± 6.05° 3 months postoperatively and to 25.3° ± 5.14° 6 months postoperatively. These results were the same as those of Chung and associates [10] who detected a 31.7% reduction in the trabecular-iris angle (from 38.1° ± 8.7° to 26.0° ± 6.5°) using UBM (ultrasound bio-microscopy) 1 month after surgery. Fernández-Vigo and associates [11] found an angle reduction of 34.5% 3 months after surgery using Fourier-domain optical coherence tomography, and they suggested that this reduction was caused by the convex shape of the ICL and not due to disturbed aqueous flow. In our study, there were no statistically significant differences between ACAs at 1 and 3 months postoperatively (p = 0.966). Thus, the initial narrowing of the ACA remained stable for 3 months post-surgery. Consistently, this was the case in Fernández-Vigo and associates' study [11] with no significant change in 3 months and in Chung and associates study [10] as there were no significant changes in ACA from 1 month postoperatively until the end of follow-up, which was a mean of 33 months. Our results showed a significant reduction in CACD by about 21.17%, 18.11%, 18.10% and 17.83% at 1, 3, 6 and 12 months postoperatively, respectively. This reduction was mainly due to vaulting of the ICL, as the CACD is measured postoperatively from the back surface of the cornea to the anterior surface of the ICL. We found statistically significant negative correlation between the vault and CACD. The central ICL vault in our study was 0.556 ± 0.033 mm 1 month postoperatively and decreased significantly to 0.431 ± 0.056 mm 3 months after implantation (p < 0.0001); it then decreased insignificantly to 0.429 ± 0.049 and 0.426 ± 0.064 mm 6 and 12 months postoperatively, respectively. These results are in line with results of Ju et al. [12]. They found that mean ACD measured with AS-OCT was 3.28 ± 0.14 mm preoperatively and 2.45 ± 0.22 mm 3 months after surgery. ACD showed a statistically significant reduction of 25.4% (p < 0.01) in their study. We found that PD insignificantly decreased by 6.7%, 6.2%, 7% and 5.7% at 1, 3, 6 and 12 months postoperatively, respectively. Although the change was statistically insignificant, it is worth mentioning that the p value was 0.062, which means it was close to the significance. This was different from results of previous studies [13, 14], where a significant reduction in PD was observed both 1 and 3 months after ICL implantation. Li and associates [13] attributed this reduction to the contact between the iris and ICL, which limits postoperative pupil movements, as they found a significant correlation between lower degrees of myopia and decreased size of the pupil. Our results were different perhaps because our patients had higher degrees of myopia as mean SE was −16.91 ± 2.37 D in our study, while it was −12.50 ± 4.28 in their study. We also found a statistically significant positive correlation between the vault and PD. This was also found by Chen et al. [9] who stated that pupil size is a vital factor in vault change, with an increasing vault observed postoperatively from 1 day to 1 week associated with the lessening effects of pharmacological miosis and increasing pupil size. IOP was elevated >21 mmHg in 14.7% (5 eyes) of our cases, with three eyes showed the increased IOP during the first week, which can be related to retained viscoelastic material, while two eyes had high IOP after 1 month; this may have been due to a steroid-induced response. This was nearly the case in Almalki and colleagues' study [15]; they found elevated IOP in 10.8% of cases. CCT showed a nonsignificant change in our cases; this was because of proper IOP control and minimal or no surgical trauma to the endothelium. Also, K readings suffered from insignificant changes because the incision was small in size (3 mm) and temporal in site. Our study was limited by the relatively small number of subjects. The follow-up period was 12 months, but some changes may continue to evolve later. We had no chance to use another imaging technique besides the Pentacam to compare their results.

Conclusions

Our results support the view that ICL implantation is a safe and effective option for treatment of high myopia and that the Pentacam can be used to evaluate anterior segment parameters. ICL implantation reduces the ACA and CACD significantly. These changes should be considered during evaluation of case eligibility for ICL implantation. ICL implantation has an insignificant effect on pupil size and corneal curvature, which may guarantee good quality of vision after surgery.
  14 in total

1.  Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography.

Authors:  José Ignacio Fernández-Vigo; Ana Macarro-Merino; Cristina Fernández-Vigo; José Ángel Fernández-Vigo; José María Martínez-de-la-Casa; Cristina Fernández-Pérez; Julián García-Feijóo
Journal:  Am J Ophthalmol       Date:  2015-11-12       Impact factor: 5.258

2.  Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia.

Authors:  Salem Almalki; Abdullah Abubaker; Nasser A Alsabaani; Deepak P Edward
Journal:  Int Ophthalmol       Date:  2015-08-12       Impact factor: 2.031

3.  Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years.

Authors:  Tae-Young Chung; Sung Chul Park; Myoung Ok Lee; Kyeon Ahn; Eui-Sang Chung
Journal:  J Refract Surg       Date:  2009-03       Impact factor: 3.573

4.  Posterior chamber phakic intraocular lens implantation for high myopia.

Authors:  Yan Ju; Xiao-Wei Gao; Bing Ren
Journal:  Int J Ophthalmol       Date:  2013-12-18       Impact factor: 1.779

5.  Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia.

Authors:  Akihito Igarashi; Kimiya Shimizu; Kazutaka Kamiya
Journal:  Am J Ophthalmol       Date:  2013-11-13       Impact factor: 5.258

6.  Assessment of the anterior chamber parameters after laser iridotomy in primary angle close suspect using Pentacam and gonioscopy.

Authors:  Alireza Esmaeili; Behzad Barazandeh; Sina Ahmadi; Alireza Haghi; Seyed Mahdi Ahmadi Hosseini; Fereshteh Abolbashari
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

7.  Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth.

Authors:  Dong Hui Lim; Min Gyu Lee; Eui-Sang Chung; Tae-Young Chung
Journal:  Am J Ophthalmol       Date:  2014-06-18       Impact factor: 5.258

8.  Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation.

Authors:  Jing Zhang; Hui-Hui Luo; Jing Zhuang; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

9.  Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up.

Authors:  Esin Sogutlu Sari; David P Pinero; Anil Kubaloglu; Pinar Sorgun Evcili; Arif Koytak; Isil Kutlutürk; Yusuf Ozerturk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-10       Impact factor: 3.117

Review 10.  Implantable collamer posterior chamber intraocular lenses: a review of potential complications.

Authors:  Paulo Fernandes; José M González-Méijome; David Madrid-Costa; Teresa Ferrer-Blasco; Jorge Jorge; Robert Montés-Micó
Journal:  J Refract Surg       Date:  2011-06-30       Impact factor: 3.573

View more
  7 in total

1.  Evaluation of impact of posterior phakic IOL implantation on biometry and effectiveness of concomitant use of anterior segment OCT on IOL power calculation for cataract surgery.

Authors:  Masayuki Ouchi
Journal:  J Cataract Refract Surg       Date:  2021-09-01       Impact factor: 3.528

2.  An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes.

Authors:  Rashmi Singh; Murugesan Vanathi; Alisha Kishore; Radhika Tandon; Divya Singh
Journal:  Indian J Ophthalmol       Date:  2020-07       Impact factor: 1.848

3.  Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses.

Authors:  Jiao Zhao; Jing Zhao; Wen Yang; Huamao Miao; Lingling Niu; Jianmin Shang; Xiaoying Wang; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2021-01-27

4.  Effect of Implantable Collamer Lens on Anterior Segment Measurement and Intraocular Lens Power Calculation Based on IOLMaster 700 and Sirius.

Authors:  Xiaoyong Chen; Di Zhang; Ziyuan Liu; Yinan Liu; Hongyuan Cai; Qianru Wu; Yu Zhang
Journal:  J Ophthalmol       Date:  2021-12-21       Impact factor: 1.909

5.  A Prospective Comparative Study between Implantable Phakic Intraocular Contact Lens and Implantable Collamer Lens in Treatment of Myopia in Adults.

Authors:  Mahmoud Rateb; Ahmed A M Gad; Dalia Tohamy; Mohamed Nagy Elmohamady
Journal:  J Ophthalmol       Date:  2022-03-28       Impact factor: 1.909

6.  Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens.

Authors:  Yuki Takagi; Takashi Kojima; Tomoya Nishida; Tomoaki Nakamura; Kazuo Ichikawa
Journal:  PLoS One       Date:  2020-11-16       Impact factor: 3.240

7.  Toric Implantable Collamer Lens for the Treatment of Myopic Astigmatism.

Authors:  Majid Moshirfar; Nour Bundogji; Alyson N Tukan; James H Ellis; Shannon E McCabe; Ayesha Patil; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Clin Ophthalmol       Date:  2021-07-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.