Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial.

Abdel Hamid Elhofi1, Hany Ahmed Helaly.   

Abstract

To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX) or manual slitlamp-assisted preoperative marking using pendulum-attached marker. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases. The mean postoperative uncorrected distance visual acuity (UCDVA) for the digital-marking group was 0.12 + 0.12 logMAR, and for the manual-marking group was 0.18 + 0.14 logMAR (P = 0.104). The mean deviation from targeted induced astigmatism (TIA) for the first group was 0.10 + 0.08 D and for the second group was 0.20 + 0.14 D (P = 0.001). The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° for the first group and was 4.33° + 2.72° for the second group (P = 0.003). Accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique.

Entities:  

Mesh:

Year:  2015        PMID: 26402830      PMCID: PMC4635770          DOI: 10.1097/MD.0000000000001618

Source DB:  PubMed          Journal:  Medicine (Baltimore)        ISSN: 0025-7974            Impact factor:   1.817


INTRODUCTION

Many patients undergoing cataract surgery have a significant corneal astigmatism. The prevalence of corneal astigmatism more than 1.5 diopters (D) ranges between 15% and 29% as reported by different studies.[1-4] The difference in the reported percentages may reflect racial differences among included samples from different countries. This reported prevalence may reach up to 47% for corneal astigmatism more than 1 D.[2] There are several methods for treating coexisting astigmatism in patients undergoing cataract surgery. These methods include steep meridian incision,[5,6] opposite clear corneal incisions,[5,7-9] toric intraocular lens (IOL),[10-12] and limbal or corneal relaxing incisions.[12-14] Nowadays, femtosecond laser platforms can improve the precision of corneal incisions.[15-17] Toric IOL is used to correct coexisting corneal astigmatism in patients undergoing cataract surgery. Good alignment of toric IOL is important to achieve effective astigmatism correction. Improper alignment of the toric IOL may be due to wrong alignment from the start or postoperative IOL rotation.[18,19] Many methods are used to align the toric IOL. The most important step is the preoperative marking of the horizontal meridian (0°–180°) while the patient is sitting. Marking of the horizontal meridian can be done manually under the guidance of different methods that includes slitlamp-assisted marking with a horizontal slit beam, slitlamp-assisted marking with a pendulum-attached marker, or nonpendular marker with a surgeon's direct visualization.[20,21] Newer technologies can provide digital image guidance for toric IOL alignment. These include the Callisto Eye with Z-Align (Carl Zeiss Meditec AG, Jena, Germany), the iTrace with Zaldivar Toric Caliper (Tracey Technologies, Houston, TX), the TrueGuide software (TrueVision 3D Surgical, Inc., Santa Barbara, CA), and the VERION Digital Marker (Alcon Laboratories, Ft. Worth, TX).[22-25] The aim of the current study was to compare the clinical outcome of digital and manual marking for toric IOL alignment.

PATIENTS AND METHODS

This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). Cases with ocular comorbidities that affected the visual acuity such as amblyopia, maculopathy, glaucoma, and uveitis were excluded. Cases with intraoperative complications that compromised the toric IOL position were excluded. All cases were performed by the same surgeon. All included patients signed an informed consent. This study was approved by the local research committee of Faculty of Medicine, Alexandria University, Egypt. The tenets of Declaration of Helsinki were followed. The eyes were randomly assigned to 1 of 2 groups according to the method of toric IOL alignment. The first group included 30 eyes with digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth). The second group included 30 eyes with manual slitlamp-assisted preoperative marking using pendulum-attached marker. Lenstar LS 900 optical biometer (Haag-Streit or Allegro Biograph, Wavelight) was used to measure the axial length used in IOL power calculations for both groups. The least amount of residual astigmatism was targeted and the incision site was modified according to the treatment plan. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases. Follow-up visit 3 to 5 weeks postoperative was performed to record patients’ uncorrected distance visual acuity (UCDVA), manifest refraction including residual refractive astigmatism, best corrected distance visual acuity, and the amount of toric IOL misalignment at the slitlamp. For the first group, VERION system was used for toric IOL power calculation and surgical planning with the input of the Lenstar LS 900 measured axial length. Maximum possible correction of the astigmatism was attempted taking into consideration the surgically induced astigmatism. A high resolution preoperative image of the eye was captured by the unit. This image was registered intraoperatively. The VERION system matches the preoperative high resolution image with the eye intraoperatively using scleral vessels, limbal vessels, and iris features. This allowed real-time tracking of the eye during the surgery. A limbal protractor and the calculated toric IOL axis were displayed over a live view of the eye on an external monitor during the surgery. This allowed toric IOL alignment guided by the digital overlay. For the second group, Lenstar LS 900 was used for toric IOL power calculation. Maximum possible correction of the astigmatism was attempted taking into consideration the surgically induced astigmatism. Manual marking was a 3-step procedure. First step was preoperative slitlamp-assisted marking of the horizontal meridian of the eye using a pendulum-attached marker. The eye should be marked while the patient is sitting upright and fixing with the other eye at a distant target to avoid cyclotorsion. The second step was intraoperative aligning a second device with angular graduations to the horizontal marks. The third step was intraoperative marking of the desired toric IOL axis of alignment using a gentian violet surgical marking pen. Clinical findings were statistically evaluated using Excel 2007 (Microsoft Corp.) and SPSS software version 15.0 (SPSS Inc, Chicago, IL). Means and standard deviations were calculated. To check for normal distribution, the Kolmogorov–Smirnov test was applied. Comparisons of the means of normally distributed data were performed with the t-tests. Percentages of cases with postoperative UCDVA > 20/40 were calculated for both groups. Percentages of cases with postoperative refractive cylinder < 0.5 D were also calculated for both groups. Chi-square test was used to compare between different percentages. A P value less than 0.05 was considered statistically significant. Vector analysis was used to calculate the deviation between actual and planned postoperative residual astigmatism.

RESULTS

The mean age of the first group (with digital marking) was 49.5 + 11.4 years (n = 30, range 28–68 years). The mean age of the second group (with manual marking) was 52.0 + 13.0 years (n = 30, range 25–70 years). There was no statistically significant difference between the 2 groups (t = −0.780, P = 0.439). The first group included 15 males and 15 females, while the second group included 17 males and 13 females. The mean preoperative corneal astigmatism for the first group (measured by the VERION system) was 2.58 + 0.89 D (range from 1.30 to 4.51 D), and for the second group (measured by the Lenstar LS 900) was 2.49 + 0.87 D (range from 1.34 to 4.90 D). There was no statistically significant difference between the 2 groups (t = 0.394, P = 0.695). The mean postoperative UCDVA for the first group was 0.12 + 0.12 logMAR (range from 0 to 0.5 logMAR), and for the second group was 0.18 + 0.14 logMAR (range from 0 to 0.5 logMAR). The difference was not statistically significant (t = −1.654, P = 0.104). In the first group, 28 eyes (93.3%) had postoperative UCDVA of 0.3 logMAR or better. In the second group, 27 eyes (90%) had postoperative UCDVA of 0.3 logMAR or better. There was not statistically significant difference between the 2 groups (P = 0.399). For both groups, no eyes lost lines of visual acuity and all eyes had a best corrected distance visual acuity of 0.3 logMAR or better. The mean postoperative residual refractive cylinder for the first group was 0.28 + 0.28 D (range 0.0–1.0 D) representing 89% of reduction in the astigmatism from preoperative levels. The mean postoperative residual refractive cylinder for the second group was 0.34 + 0.33 D (range 0.0–1.5 D) representing 86.3% of reduction in the astigmatism from preoperative levels. This difference was not statistically significant (t = −0.837, P = 0.406). Eyes with postoperative residual refractive cylinder of 0.5 D or less represented 90% (27 eyes) of the first group versus 83.3% (25 eyes) of the second group (P = 0.164). Vector analysis was used to calculate the deviation vector (DV) which represents the difference between the targeted induced astigmatism (TIA) and the actual postoperative refractive cylinder. The mean deviation from TIA for the first group was 0.10 + 0.08 D (range 0.02–0.40 D). The mean deviation from TIA for the second group was 0.20 + 0.14 D (range 0.04–0.6 D). There was a statistically significant difference between the 2 groups (t = −3.449, P = 0.001). All eyes of the first group were within +0.5 D of the TIA versus 29 eyes (96.67%) of the second group. The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° (range from 0 to 7°) for the first group and was 4.33° + 2.72° (range from 1° to 12°) for the second group. This was significantly different (t = −3.159, P = 0.003). Postoperative toric IOL misalignment of 5° or less occurred in 27 eyes (90%) of the first group in comparison to 25 eyes (83.3%) of the second group. Table 1 summarizes the comparison between VERION-guided group and manual-marking group.
TABLE 1

Comparison Between VERION-Guided Group and Manual-Marking Group

Comparison Between VERION-Guided Group and Manual-Marking Group

DISCUSSION

Reduction of residual postoperative refractive astigmatism improves UCDVA after the cataract surgery. Toric IOL implantation during cataract surgery allows treating coexisting corneal astigmatism. Villegas et al[26] mentioned that correcting corneal astigmatism of <0.50 D does not improve visual outcome after the cataract surgery. In the current study, patients were selected to have >1 D of corneal astigmatism to get benefit from toric IOL. Holland et al[27] stated that patients with >0.75 D of corneal astigmatism had better visual outcome with implantation of toric IOLs more than with implantation of monofocal IOLs as more patients achieved an UCDVA > 0.3 logMAR and had a lower mean absolute residual refractive astigmatism. The toric IOL has marks that indicate the flat meridian (plus cylinder axis). Precise alignment of the toric IOL during surgery is the most important step in achieving the desired effect of the calculated astigmatism correction. When the toric IOL is misaligned or rotates postoperatively, there is a reduction in its effect on the planned axis of alignment and introduction of a new astigmatism in another axis. Approximately, there is 3% to 3.5% residual astigmatism for every 1° of toric IOL rotation. This means that with 30° of rotation there is 100% of residual astigmatism but on a different axis.[28] Preoperative manual marking or capturing of the reference image should be done while the patient is in a sitting position to avoid the effect of cyclotorsion. Upon lying down, around 2° to 3° of cyclotorsion occurs. It is reported that this cyclotorsion can reach up to 14°.[20,29] The advantage of the VERION system is the integration of preoperative capturing of a reference image, obtaining the keratometry readings, preoperative planning of the surgery including incision site and toric IOL choice and power, and intraoperative guidance with an overlay over the live view. In the current study, manual preoperative marking was done by pendulum-attached marker because studies showed it had more accurate results among manual-marking techniques.[20,21] As regards the included patients of the 2 groups, there was no statistically or clinically significant difference in their age, sex composition, and preoperative corneal astigmatism levels. Patients with digital marking showed clinically better visual outcome as regards mean postoperative UCDVA and the percentage of cases with UCDVA > 0.3 logMAR. This difference was not statistically significant. In the current study, patients achieving postoperative UCDVA > 0.3 logMAR represented around 90% to 93% of the cases. The reported percentage of patients achieving postoperative UCDVA > 0.3 logMAR after toric IOL implantation represented 70% to 100% of the cases.[30,31] As regards the refractive outcome, both groups showed marked reduction of preoperative astigmatism around 86% to 89% with no statistically significant difference between the 2 groups. The reported percentage of patients with postoperative residual refractive astigmatism <0.5 D after toric IOL implantation represented 25% to 100% of the cases.[32,33] However, the digital-marking group showed statistically significant better refractive outcome as regards the mean deviation from TIA which was 0.10 + 0.08 D and all eyes were within +0.5 D of the TIA. The digital-marking group showed statistically significant better results as regards the mean postoperative toric IOL misalignment measured by the slitlamp which was 2.4° + 1.96°. Postoperative toric IOL misalignment of <5 occurred in 27 eyes (90%). The reported mean postoperative toric IOL misalignment ranged from 2.5 to 4 D.[34-36] In conclusion, accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique.
  29 in total

1.  Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation.

Authors:  Joseph J K Ma; Santos S Tseng
Journal:  J Cataract Refract Surg       Date:  2008-10       Impact factor: 3.351

2.  Comparison of 3 marking techniques in preoperative assessment of toric intraocular lenses using a wavefront aberrometer.

Authors:  Young Jae Woo; Hun Lee; Hong Seok Kim; Eung Kweon Kim; Kyoung Yul Seo; Tae-im Kim
Journal:  J Cataract Refract Surg       Date:  2015-06-17       Impact factor: 3.351

3.  Minimum amount of astigmatism that should be corrected.

Authors:  Eloy A Villegas; Encarna Alcón; Pablo Artal
Journal:  J Cataract Refract Surg       Date:  2014-01       Impact factor: 3.351

4.  Changes in corneal astigmatism among patients with visually significant cataract.

Authors:  Douglas A M Lyall; Sathish Srinivasan; Jia Ng; Elizabeth Kerr
Journal:  Can J Ophthalmol       Date:  2014-06       Impact factor: 1.882

5.  High-cylinder acrylic toric intraocular lenses: a case series of eyes with cataracts and large amounts of corneal astigmatism.

Authors:  Guadalupe Cervantes-Coste; Laura Garcia-Ramirez; Erick Mendoza-Schuster; Cecilio Velasco-Barona
Journal:  J Refract Surg       Date:  2012-02-15       Impact factor: 3.573

6.  Accuracy of toric intraocular lens implantation in cataract and refractive surgery.

Authors:  Nienke Visser; Tos T J M Berendschot; Noël J C Bauer; Jessica Jurich; Oliver Kersting; Rudy M M A Nuijts
Journal:  J Cataract Refract Surg       Date:  2011-08       Impact factor: 3.351

7.  Correction of astigmatism after cataract surgery using the light adjustable lens: a 1-year follow-up pilot study.

Authors:  Alejandro Lichtinger; Christopher A Sandstedt; Daniel M Schwartz; Arturo S Chayet
Journal:  J Refract Surg       Date:  2011-01-17       Impact factor: 3.573

8.  Cataract patients in a defined Swedish population 1986-1990. II. Preoperative observations.

Authors:  K Ninn-Pedersen; U Stenevi; B Ehinger
Journal:  Acta Ophthalmol (Copenh)       Date:  1994-02

9.  Astigmatism management in cataract surgery with the AcrySof toric intraocular lens.

Authors:  Noël J C Bauer; Niels E de Vries; Carroll A B Webers; Fred Hendrikse; Rudy M M A Nuijts
Journal:  J Cataract Refract Surg       Date:  2008-09       Impact factor: 3.351

10.  Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

Authors:  Javed Hussain Farooqui; Mansi Sharma; Archana Koul; Ranjan Dutta; Noshir Minoo Shroff
Journal:  Oman J Ophthalmol       Date:  2017 May-Aug
View more
  21 in total

1.  Comparison of biometric measurements obtained by the Verion Image-Guided System versus the auto-refracto-keratometer.

Authors:  Cecilio Velasco-Barona; Guadalupe Cervantes-Coste; Erick Mendoza-Schuster; Claudia Corredor-Ortega; Nadia L Casillas-Chavarín; Alejandro Silva-Moreno; Manuel Garza-León; Roberto Gonzalez-Salinas
Journal:  Int Ophthalmol       Date:  2017-04-25       Impact factor: 2.031

2.  Toric IOL positioning with a no-touch head-up display axis alignment.

Authors:  J Luebke; D Boehringer; P Maier; T Reinhard; P Eberwein
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

3.  Evaluation of axis alignment and refractive results of toric phakic IOL using image-guided system.

Authors:  Sherif Emerah
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

Review 4.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

5.  Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

Authors:  Jeewan S Titiyal; Manpreet Kaur; Cijin P Jose; Ruchita Falera; Ashutosh Kinkar; Lalit Ms Bageshwar
Journal:  Clin Ophthalmol       Date:  2018-04-24

6.  Early-stage clinical outcomes and rotational stability of TECNIS toric intraocular lens implantation in cataract cases with long axial length.

Authors:  Suhong He; Xiang Chen; Xingdi Wu; Yajuan Ma; Xuewen Yu; Wen Xu
Journal:  BMC Ophthalmol       Date:  2020-05-25       Impact factor: 2.209

7.  Refractive Status in Eyes Implanted with Toric and Nontoric Intraocular Lenses during Combined Cataract Surgery and Microhook Ab Interno Trabeculotomy.

Authors:  Yasuyuki Takai; Kazunobu Sugihara; Mihoko Mochiji; Kaoru Manabe; Aika Tsutsui; Masaki Tanito
Journal:  J Ophthalmol       Date:  2021-05-29       Impact factor: 1.909

8.  Agreement between Keratometric readings by VERION image guided System, Galilei G4 and Pentacam.

Authors:  Asad Habib; Muhammad Saim Khan; Mazhar Ishaq; Muhammad Amer Yaqub
Journal:  Pak J Med Sci       Date:  2018 May-Jun       Impact factor: 1.088

9.  Retrospective analysis of an intraoperative aberrometry database: a study investigating absolute prediction in eyes implanted with low cylinder power toric intraocular lenses.

Authors:  Robert J Cionni; Michael Breen; Cody Hamilton; Ravaughn Williams
Journal:  Clin Ophthalmol       Date:  2019-08-06

10.  Mobile App for Pre- and Intraoperative Assessment of Astigmatism Correction with Toric Intraocular Lenses in Cataract Surgery.

Authors:  Francisco Aecio Fernandes Dias; Vinicius Jose Fernandes Dias; Barbara de Araujo Lima Dutra; Anna Christina Siqueira Marques; Edgar Marçal; Abrahao da Rocha Lucena; Joao Crispim Ribeiro
Journal:  J Ophthalmol       Date:  2020-03-15       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.