Literature DB >> 22335205

High-cylinder acrylic toric intraocular lenses: a case series of eyes with cataracts and large amounts of corneal astigmatism.

Guadalupe Cervantes-Coste1, Laura Garcia-Ramirez, Erick Mendoza-Schuster, Cecilio Velasco-Barona.   

Abstract

PURPOSE: To examine the stability and efficacy of high-cylinder power AcrySof toric intraocular lenses (IOLs), models SN60T6, SN60T7, SN60T8, and SN60T9 (Alcon Laboratories Inc).
METHODS: Eligible eyes had cataract and symmetric corneal astigmatism > 2.25 diopters (D). Outcomes included monocular uncorrected distance visual acuity (UDVA), manifest refraction, and assessment of IOL axis.
RESULTS: Nineteen eyes from 14 patients had preoperative corneal astigmatism of 4.00 ± 1.10 D. Postoperatively, residual refractive cylinder was 0.55 ± 0.60 D at 3 months. Uncorrected distance visual acuity was 1.3 ± 0.5 logMAR preoperatively and improved to 0.11 ± 0.09 logMAR 3 months postoperatively (P<.0001). All IOLs were stable within 5°.
CONCLUSIONS: The IOLs were stable and effective in correcting high amounts of preexisting astigmatism at the time of cataract surgery. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22335205     DOI: 10.3928/1081597X-20120208-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Toric Intraocular Lens Implantation in the Correction of Moderate-To-High Corneal Astigmatism in Cataract Patients: Clinical Efficacy and Safety.

Authors:  Xiaodi Qiu; Yumeng Shi; Xiaoyan Han; Zhixiang Hua; Yi Lu; Jin Yang
Journal:  J Ophthalmol       Date:  2021-01-20       Impact factor: 1.909

2.  High-cylinder toric intraocular lens implantation versus combined surgery of low-cylinder intraocular lens implantation and limbal relaxing incision for high-astigmatism eyes.

Authors:  Masayuki Ouchi
Journal:  Clin Ophthalmol       Date:  2014-03-31

3.  Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens.

Authors:  Wojciech Lubiński; Beata Kaźmierczak; Jolanta Gronkowska-Serafin; Karolina Podborączyńska-Jodko
Journal:  J Ophthalmol       Date:  2016-02-28       Impact factor: 1.909

4.  Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial.

Authors:  Abdel Hamid Elhofi; Hany Ahmed Helaly
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.