Jeewan S Titiyal1, Manpreet Kaur1, Cijin P Jose1, Ruchita Falera1, Ashutosh Kinkar1, Lalit Ms Bageshwar1.
Abstract
PURPOSE: To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. PATIENTS AND METHODS: This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30.Entities:
Keywords: Callisto eye and Z align toric IOL; image-guided surgery; manual marking toric IOL; toric IOL alignment; visual quality image-guided surgery; visual quality toric IOL
Year: 2018 PMID: 29731603 PMCID: PMC5923224 DOI: 10.2147/OPTH.S164175
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1Postoperative assessment of toric IOL alignment with ray tracing aberrometer in a case in group I (conventional manual marking). A 6° deviation from target axis of implantation is present.
Abbreviation: IOL, intraocular lens.
Figure 2Postoperative assessment of toric IOL alignment with ray tracing aberrometer in a case in group II (image-guided surgery). A 1° deviation from target axis of implantation is present.
Abbreviation: IOL, intraocular lens.
Demographic details and preoperative characteristics of cases undergoing toric IOL implantation
| Demographic variables | Group I | Group II | |
|---|---|---|---|
| Age (years) | 63.1±13.7 | 60.1±10.3 | 0.271 |
| Sex (M:F) | 17:23 | 19:21 | 0.822 |
| Right eye: left eye | 24:16 | 18:22 | 0.263 |
| Corneal cylinder (D) | 2.1±0.9 | 2.5±0.9 | 0.057 |
| Defocus equivalent | 1.2±2.8 | 2.0±3.2 | 0.211 |
| Keratometry 1 | 42.6±1.8 | 42±1.8 | 0.148 |
| Keratometry 2 | 44.6±1.9 | 44.4±2.2 | 0.724 |
| UDVA (logMAR units) | 0.78±0.37 | 0.97±0.28 | 0.013 |
| CDVA (logMAR units) | 0.56±0.38 | 0.59±0.29 | 0.746 |
| IOP (mmHg) | 14.9±3.01 | 14.4±3.04 | 0.508 |
| Target axis of implantation | 100.2±74.8 | 104.2±68.8 | 0.804 |
Abbreviations: M, male; F, female; D, Diopter; UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; logMAR, logarithm of minimum angle of resolution; IOP, intraocular pressure.
Postoperative visual outcomes and toric IOL alignment in cases undergoing toric IOL implantation with manual marking or image-guided surgery
| Outcome measures | Group I | Group II | |
|---|---|---|---|
| Refractive sphere | 0.39±0.44 | 0.15±0.79 | 0.105 |
| Refractive cylinder | −0.89±0.35 | −0.64±0.36 | |
| Corneal cylinder | 2.1±0.9 | 2.3±1.2 | 0.474 |
| Defocus equivalent | 0.01±0.2 | 0.07±0.3 | 0.208 |
| UDVA (logMAR units) POD 1 | 0.055±0.09 | 0.03±0.07 | 0.184 |
| CDVA (logMAR units) POD 1 | 0.01±0.03 | 0.005±0.02 | 0.402 |
| UDVA (logMAR units) POD 30 | 0.025±0.06 | 0.017±0.05 | 0.541 |
| CDVA (logMAR units) POD 30 | 0.008±0.03 | 0.005±0.02 | 0.649 |
| IOP (mmHg) | 15.2±2.9 | 14.4±2.9 | 0.272 |
| Axis of IOL implantation | 82.6±72.3 | 104.6±69.0 | 0.169 |
| Deviation from target axis (POD 1) | 5.8±3.7 | 3.7±2.8 | |
| Deviation from target axis (POD 30) | 5.5±3.3 | 3.6±2.6 |
Note: p-values less than 0.05 are shown in bold.
Abbreviations: D, Diopter; UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; logMAR, logarithm of minimum angle of resolution; IOP, intraocular pressure; IOL, intraocular lens; POD, postoperative day.
Assessment of visual quality in cases undergoing toric intraocular lens alignment with manual marking or image-guided surgery
| Visual quality parameters | Group I | Group II | |
|---|---|---|---|
| Strehl ratio internal | 0.051±0.056 | 0.109±0.142 | |
| Strehl ratio total | 0.090±0.104 | 0.136±0.182 | 0.170 |
| MTF internal 5 cpd | 0.344±0.214 | 0.484±0.235 | |
| MTF internal 10 cpd | 0.172±0.115 | 0.249±0.174 | |
| MTF internal 15 cpd | 0.107±0.072 | 0.153±0.121 | |
| MTF internal average | 0.218±0.085 | 0.273±0.115 | |
| MTF total 5 cpd | 0.517±0.202 | 0.550±0.209 | 0.480 |
| MTF total 10 cpd | 0.249±0.146 | 0.273±0.178 | 0.508 |
| MTF total 15 cpd | 0.162±0.103 | 0.187±0.119 | 0.327 |
| MTF total average | 0.282±0.101 | 0.302±0.109 | 0.406 |
| Strehl ratio internal | 0.075±0.081 | 0.149±0.162 | |
| Strehl ratio total | 0.101±0.085 | 0.134±0.120 | 0.160 |
| MTF internal 5 cpd | 0.373±0.250 | 0.492±0.271 | |
| MTF internal 10 cpd | 0.190±0.142 | 0.264±0.186 | |
| MTF internal 15 cpd | 0.110±0.078 | 0.165±0.129 | |
| MTF internal average | 0.226±0.102 | 0.282±0.130 | |
| MTF total 5 cpd | 0.546±0.179 | 0.599±0.215 | 0.245 |
| MTF total 10 cpd | 0.277±0.136 | 0.312±0.169 | 0.301 |
| MTF total 15 cpd | 0.197±0.158 | 0.212±0.168 | 0.675 |
| MTF total average | 0.299±0.088 | 0.319±0.107 | 0.343 |
Note: p-values less than 0.05 are shown in bold.
Abbreviations: MTF, modulation transfer function; cpd, cycles per degree.
Correlation between postoperative visual quality and deviation from target axis of implantation of toric intraocular lens on postoperative days 1 and 30
| Correlation parameters | Deviation from target axis, day 1
| Deviation from target axis, day 30
| ||
|---|---|---|---|---|
| Pearson’s correlation coefficient | Pearson’s correlation coefficient | |||
| Strehl ratio internal | −0.621 | <0.001 | −0.730 | <0.001 |
| Strehl ratio total | −0.396 | <0.001 | −0.469 | <0.001 |
| MTF internal 5 cpd | −0.788 | <0.001 | −0.795 | <0.001 |
| MTF internal 10 cpd | −0.710 | <0.001 | −0.794 | <0.001 |
| MTF internal 15 cpd | −0.671 | <0.001 | −0.772 | <0.001 |
| MTF internal average | −0.771 | <0.001 | −0.828 | <0.001 |
| MTF total 5 cpd | −0.307 | 0.006 | −0.313 | 0.005 |
| MTF total 10 cpd | −0.322 | 0.004 | −0.206 | 0.067 |
| MTF total 15 cpd | −0.309 | 0.005 | −0.232 | 0.038 |
| MTF total average | −0.320 | 0.004 | −0.239 | 0.033 |
Abbreviations: MTF, modular transfer function; cpd, cycles per degree.