Literature DB >> 18812110

Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation.

Joseph J K Ma1, Santos S Tseng.   

Abstract

A simple technique for the accurate surgical alignment of toric phakic and aphakic intraocular lenses (IOLs) is described. The mathematical relationship between toric misalignment and cylinder error is reviewed to demonstrate the importance of toric lens alignment in the setting of increased rotational stability with newer generation lenses. A formula for calculating the exact lens misalignment given a manifest cylinder is also presented.

Entities:  

Mesh:

Year:  2008        PMID: 18812110     DOI: 10.1016/j.jcrs.2008.04.041

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  28 in total

1.  Optical performance of toric intraocular lenses in the presence of decentration.

Authors:  Bin Zhang; Jin-Xue Ma; Dan-Yan Liu; Ying-Hua Du; Cong-Rong Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  The effect of head tilt on keratometric measurement using the IOLMaster.

Authors:  C Y Park; J R Do; S H Kim; C-Y Lim; R S Chuck
Journal:  Eye (Lond)       Date:  2013-09-20       Impact factor: 3.775

3.  Comparison of keratometric measurements obtained by the Verion Image Guided System with optical biometry and auto-keratorefractometer.

Authors:  Leyla Asena; Sirel Gür Güngör; Ahmet Akman
Journal:  Int Ophthalmol       Date:  2016-06-07       Impact factor: 2.031

4.  Simple and accurate alignment of toric intraocular lenses and evaluation of their rotation errors using anterior segment optical coherence tomography.

Authors:  Kazuhiro Watanabe; Kazuno Negishi; Hidemasa Torii; Megumi Saiki; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2011-10-29       Impact factor: 2.447

5.  Optical quality of toric intraocular lens implantation in cataract surgery.

Authors:  Xian-Wen Xiao; Jing Hao; Hong Zhang; Fang Tian
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  Clinical outcomes, predictability and rotational stability following implantation of Eyecryl toric versus TECNIS toric intraocular lenses-A comparative study.

Authors:  Sheetal Brar; Dishitha P Rathod; R P Nikhil; Sri Ganesh
Journal:  Int Ophthalmol       Date:  2021-07-22       Impact factor: 2.031

7.  Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction.

Authors:  Bin Zhang; Jing-Xue Ma; Dan-Yan Liu; Cong-Rong Guo; Ying-Hua Du; Xiu-Jin Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2016-09-18       Impact factor: 1.779

8.  Spontaneous Rotation of a Toric Implantable Collamer Lens.

Authors:  Alejandro Navas; Mayeli Muñoz-Ocampo; Enrique O Graue-Hernández; Arturo Gómez-Bastar; Tito Ramirez-Luquín
Journal:  Case Rep Ophthalmol       Date:  2010-11-29

9.  Reverse optic capture to stabilize a toric intraocular lens.

Authors:  Howard V Gimbel; Anika Amritanand
Journal:  Case Rep Ophthalmol       Date:  2013-09-26

10.  Evaluation of Intraocular Lens Rotational Stability in a Multicenter Clinical Trial.

Authors:  John A Vukich; Robert E Ang; Benjamin J K Straker; Devi Priya Janakiraman; Pamela J Smith; Juan F Batlle; Kevin L Waltz
Journal:  Clin Ophthalmol       Date:  2021-07-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.