Literature DB >> 25076481

Surgical management of astigmatism with toric intraocular lenses.

Bruna V Ventura1, Li Wang1, Mitchell P Weikert1, Shaun B Robinson1, Douglas D Koch1.   

Abstract

Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for choosing the correct toric IOL power and for planning optimal alignment. When calculating the power of toric IOLs, it is important to consider anterior and posterior corneal astigmatism, along with the surgically induced astigmatism. Accurate toric lens alignment along the calculated meridian is also crucial to achieve effective astigmatism correction. There are several techniques to guide IOL alignment, including the traditional manual marking technique and automated systems based on anatomic and topographic landmarks. The aim of this review is to provide an overview on astigmatism management with toric IOLs, including relevant patient selection criteria, corneal astigmatism measurement, toric IOL power calculation, toric IOL alignment, clinical outcomes and complications.

Entities:  

Mesh:

Year:  2014        PMID: 25076481     DOI: 10.5935/0004-2749.20140032

Source DB:  PubMed          Journal:  Arq Bras Oftalmol        ISSN: 0004-2749            Impact factor:   0.872


  11 in total

1.  Comparison of the Orientation of the Corneal Steep Meridian Determined by Image-Guided System and Manual Method in the Same Eye.

Authors:  Tsutomu Ohashi; Takashi Kojima
Journal:  Clin Ophthalmol       Date:  2020-12-01

Review 2.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

3.  Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system.

Authors:  Javier Mendicute; Thierry Amzallag; Lixin Wang; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2018-08-21

4.  Novel method for preventing cyclorotation in Ziemer Femto LDV Z8 femtosecond laser-assisted cataract surgery with Verion image-guided system.

Authors:  Hung-Yuan Lin; Ya-Jung Chuang; Pi-Jung Lin; Yi-Ju Ho
Journal:  Clin Ophthalmol       Date:  2019-02-20

5.  Comparison between using INTEGRA and manual method in determining axis for intraocular lens implantation: Preliminary retrospective study.

Authors:  Marcin Jaworski; Dorota Wyględowska-Promieńska; Piotr Jaworski; Krzysztof Jaskot; Robert Bieda; Richard Packard
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

6.  Randomized trial comparing visual outcomes of toric intraocular lens implantation using manual and digital marker.

Authors:  Shreesha K Kodavoor; J Divya; Ramamurthy Dandapani; Chitra Ramamurthy; Shreyas Ramamurthy; Gitansha Sachdev
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

7.  Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens.

Authors:  Wojciech Lubiński; Beata Kaźmierczak; Jolanta Gronkowska-Serafin; Karolina Podborączyńska-Jodko
Journal:  J Ophthalmol       Date:  2016-02-28       Impact factor: 1.909

8.  Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens.

Authors:  Alice T Epitropoulos
Journal:  J Ophthalmol       Date:  2016-01-13       Impact factor: 1.909

9.  Mobile App for Pre- and Intraoperative Assessment of Astigmatism Correction with Toric Intraocular Lenses in Cataract Surgery.

Authors:  Francisco Aecio Fernandes Dias; Vinicius Jose Fernandes Dias; Barbara de Araujo Lima Dutra; Anna Christina Siqueira Marques; Edgar Marçal; Abrahao da Rocha Lucena; Joao Crispim Ribeiro
Journal:  J Ophthalmol       Date:  2020-03-15       Impact factor: 1.909

10.  Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial.

Authors:  Abdel Hamid Elhofi; Hany Ahmed Helaly
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.