PURPOSE: To investigate the efficacy of two widely used scatter mitigation methods: antiscatter grids (ASGs) and beam modulating with bowtie filters (BTFs), in combination with subtractive scatter correction or zeroth order normalization phantom calibration, for improving image noise, contrast, contrast-to-noise ratio (CNR), and image uniformity for on-board cone-beam CT (CBCT) imaging systems used for image-guided radiation therapy. METHODS: PTRAN Monte Carlo CBCT x-ray projections of head and pelvic phantoms were calculated for combinations of beam-modulation and scatter rejection methods and images were reconstructed by in-house developed software. In addition, a simple one-dimensional analytic model was developed to predict scatter-to-primary ratio (SPR) and CNR as a function of cylindrical phantom thickness, ASG transmission, and beam modulation with bow-tie filters. RESULTS: ASGs were found to have slightly negative or no effect on head phantom image CNR and to modestly improve CNR (10%-20%) in pelvic phantom images. However, scatter subtraction and norm-phantom calibration perform better when applied on data acquired with ASGs. Scatter subtraction improves CT number accuracy, but increases noise, and in high SPR/low primary-photon transmission scenarios can dramatically reduce CNR and introduce streaking artifacts. The BTF is found to reduce SPR and image noise, resulting in a better trade-off between CNR and imaging dose, but introduces a circular band artifact. CONCLUSIONS: Our study shows that ASGs have a modest positive impact in pelvic scans and negative in head scans, scatter subtraction improves the HU accuracy but reduces CNR, while BTF has a clearly positive effect.
PURPOSE: To investigate the efficacy of two widely used scatter mitigation methods: antiscatter grids (ASGs) and beam modulating with bowtie filters (BTFs), in combination with subtractive scatter correction or zeroth order normalization phantom calibration, for improving image noise, contrast, contrast-to-noise ratio (CNR), and image uniformity for on-board cone-beam CT (CBCT) imaging systems used for image-guided radiation therapy. METHODS: PTRAN Monte Carlo CBCT x-ray projections of head and pelvic phantoms were calculated for combinations of beam-modulation and scatter rejection methods and images were reconstructed by in-house developed software. In addition, a simple one-dimensional analytic model was developed to predict scatter-to-primary ratio (SPR) and CNR as a function of cylindrical phantom thickness, ASG transmission, and beam modulation with bow-tie filters. RESULTS: ASGs were found to have slightly negative or no effect on head phantom image CNR and to modestly improve CNR (10%-20%) in pelvic phantom images. However, scatter subtraction and norm-phantom calibration perform better when applied on data acquired with ASGs. Scatter subtraction improves CT number accuracy, but increases noise, and in high SPR/low primary-photon transmission scenarios can dramatically reduce CNR and introduce streaking artifacts. The BTF is found to reduce SPR and image noise, resulting in a better trade-off between CNR and imaging dose, but introduces a circular band artifact. CONCLUSIONS: Our study shows that ASGs have a modest positive impact in pelvic scans and negative in head scans, scatter subtraction improves the HU accuracy but reduces CNR, while BTF has a clearly positive effect.
Authors: David A Jaffray; Jeffrey H Siewerdsen; John W Wong; Alvaro A Martinez Journal: Int J Radiat Oncol Biol Phys Date: 2002-08-01 Impact factor: 7.038
Authors: Dandan Zheng; John C Ford; Jun Lu; Dimitrios Lazos; Geoffrey D Hugo; Damodar Pokhrel; Lisha Zhang; Jeffrey F Williamson Journal: Med Phys Date: 2011-05 Impact factor: 4.071
Authors: A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen Journal: Med Phys Date: 2013-05 Impact factor: 4.071
Authors: Joshua D Evans; Bruce R Whiting; David G Politte; Joseph A O'Sullivan; Paul F Klahr; Jeffrey F Williamson Journal: Phys Med Date: 2013-01-21 Impact factor: 2.685