The influence of bowtie filtration on cone-beam CT image quality.

N Mail1, D J Moseley, J H Siewerdsen, D A Jaffray.   

Abstract

The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie filter implemented in a system for image-guided radiation therapy (Elekta oncology system, XVI) as a compensator for improved image quality through fluence modulation, reduction in x-ray scatter, and reduction in patient dose. Dose measurements with and without the bowtie filter were performed on a CTDI Dose phantom and an empirical fit was made to calculate dose for any radial distance from the central axis of the phantom. Regardless of patient size, shape, anatomical site, and field of view, the bowtie filter results in an overall improvement in CT number accuracy, image uniformity, low-contrast detectability, and imaging dose. The implemented bowtie filter offers a significant improvement in imaging performance and is compatible with the current clinical system for image-guided radiation therapy.

Entities:  

Mesh:

Year:  2009        PMID: 19235370     DOI: 10.1118/1.3017470

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  56 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Dynamic fluence field modulation for miscentered patients in computed tomography.

Authors:  Andrew Mao; Grace J Gang; William Shyr; Reuven Levinson; Jeffrey H Siewerdsen; Satomi Kawamoto; J Webster Stayman
Journal:  J Med Imaging (Bellingham)       Date:  2018-10-24

4.  Bowtie filtration for dedicated cone beam CT of the head and neck: a simulation study.

Authors:  G Zhang; N Marshall; R Jacobs; Q Liu; H Bosmans
Journal:  Br J Radiol       Date:  2013-05-31       Impact factor: 3.039

5.  Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT).

Authors:  Mingshan Sun; Tamás Nagy; Gary Virshup; Larry Partain; Markus Oelhafen; Josh Star-Lack
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Scatter correction method for x-ray CT using primary modulation: phantom studies.

Authors:  Hewei Gao; Rebecca Fahrig; N Robert Bennett; Mingshan Sun; Josh Star-Lack; Lei Zhu
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

7.  Bow-tie wobble artifact: effect of source assembly motion on cone-beam CT.

Authors:  Dandan Zheng; John C Ford; Jun Lu; Dimitrios Lazos; Geoffrey D Hugo; Damodar Pokhrel; Lisha Zhang; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

8.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

9.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  Improved cone-beam computed tomography in supine and prone breast radiotherapy. Surface reconstruction, radiation exposure, and clinical workflow.

Authors:  A De Puysseleyr; T Mulliez; A Gulyban; E Bogaert; T Vercauteren; T Van Hoof; J Van de Velde; R Van Den Broecke; C De Wagter; W De Neve
Journal:  Strahlenther Onkol       Date:  2013-10-03       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.