Literature DB >> 615896

Noise due to photon counting statistics in computed X-ray tomography.

D A Chesler, S J Riederer, N J Pelc.   

Abstract

A general expression is derived for the noise due to photon counting statistics in computed X-ray tomography. The variance is inversely proportional to the cube of the resolution distance. For scanners using a water box, the noise in the reconstructed image depends inversely on the number of detected primary photons, summed over all angles, that have passed through a resolution element. Predictions of this formula agree well with the results of computer simulations. It is shown how this formula can be used to determine such parameters as required X-ray flux, detector counting rate, and dose, with special emphasis on tradeoffs between these parameters and resolution. It is also shown that to determine the X-ray attenuation coefficient of a resolution element to a given precision, the number of photons required by computed X-ray tomography is close to a theoretical limit.

Entities:  

Mesh:

Year:  1977        PMID: 615896     DOI: 10.1097/00004728-197701000-00009

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  30 in total

1.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

3.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

Review 4.  Micro-computed tomography of the lungs and pulmonary-vascular system.

Authors:  Erik L Ritman
Journal:  Proc Am Thorac Soc       Date:  2005

5.  Noise simulation in cone beam CT imaging with parallel computing.

Authors:  Shu-Ju Tu; Chris C Shaw; Lingyun Chen
Journal:  Phys Med Biol       Date:  2006-02-15       Impact factor: 3.609

6.  Direct two-dimensional reconstruction algorithm for an inverse-geometry CT system.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

7.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience.

Authors:  Brian E Nett; Shuai Leng; Joseph N Zambelli; Scott B Reeder; Michael A Speidel; Guang-Hong Chen
Journal:  Acad Radiol       Date:  2008-01       Impact factor: 3.173

Review 9.  Recent and future directions in CT imaging.

Authors:  Norbert J Pelc
Journal:  Ann Biomed Eng       Date:  2014-01-17       Impact factor: 3.934

10.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

View more