Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scanner.

Joshua D Evans1, Bruce R Whiting, David G Politte, Joseph A O'Sullivan, Paul F Klahr, Jeffrey F Williamson.   

Abstract

PURPOSE: To present a framework for characterizing the data needed to implement a polyenergetic model-based statistical reconstruction algorithm, Alternating Minimization (AM), on a commercial fan-beam CT scanner and a novel method for assessing the accuracy of the commissioned data model.
METHODS: The X-ray spectra for three tube potentials on the Philips Brilliance CT scanner were estimated by fitting a semi-empirical X-ray spectrum model to transmission measurements. Spectral variations due to the bowtie filter were computationally modeled. Eight homogeneous cylinders of PMMA, Teflon and water with varying diameters were scanned at each energy. Central-axis scatter was measured for each cylinder using a beam-stop technique. AM reconstruction with a single-basis object-model matched to the scanned cylinder's composition allows assessment of the accuracy of the AM algorithm's polyenergetic data model. Filtered-backprojection (FBP) was also performed to compare consistency metrics such as uniformity and object-size dependence.
RESULTS: The spectrum model fit measured transmission curves with residual root-mean-square-error of 1.20%-1.34% for the three scanning energies. The estimated spectrum and scatter data supported polyenergetic AM reconstruction of the test cylinders to within 0.5% of expected in the matched object-model reconstruction test. In comparison to FBP, polyenergetic AM exhibited better uniformity and less object-size dependence.
CONCLUSIONS: Reconstruction using a matched object-model illustrate that the polyenergetic AM algorithm's data model was commissioned to within 0.5% of an expected ground truth. These results support ongoing and future research with polyenergetic AM reconstruction of commercial fan-beam CT data for quantitative CT applications.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Alternating Minimization; Model-based statistical iterative reconstruction; Polyenergetic statistical reconstruction; Quantitative computed tomography

Mesh:

Year:  2013        PMID: 23343747      PMCID: PMC3640746          DOI: 10.1016/j.ejmp.2012.12.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  42 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

2.  Efficient object scatter correction algorithm for third and fourth generation CT scanners.

Authors:  B Ohnesorge; T Flohr; K Klingenbeck-Regn
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

3.  Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants.

Authors:  Omar Chibani; Jeffrey F Williamson; Dorin Todor
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

4.  Magnitude and effects of x-ray scatter in a 256-slice CT scanner.

Authors:  Masahiro Endo; Shinichiro Mori; Takanori Tsunoo; Hiroaki Miyazaki
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

5.  Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.

Authors:  Giovanni M Lasio; Bruce R Whiting; Jeffrey F Williamson
Journal:  Phys Med Biol       Date:  2007-04-02       Impact factor: 3.609

Review 6.  Anniversary paper: past and current issues, and trends in brachytherapy physics.

Authors:  Bruce R Thomadsen; Jeffrey F Williamson; Mark J Rivard; Ali S Meigooni
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

7.  Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.

Authors:  Joshua D Evans; David G Politte; Bruce R Whiting; Joseph A O'Sullivan; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

Review 8.  Quantitative CT for determination of bone mineral density: a review.

Authors:  C E Cann
Journal:  Radiology       Date:  1988-02       Impact factor: 11.105

9.  The effects of scatter in x-ray computed tomography.

Authors:  P M Joseph; R D Spital
Journal:  Med Phys       Date:  1982 Jul-Aug       Impact factor: 4.071

Review 10.  Brain perfusion CT in acute stroke: current status.

Authors:  Matthias König
Journal:  Eur J Radiol       Date:  2003-03       Impact factor: 3.528

View more
  6 in total

1.  A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation.

Authors:  Dong Han; Jeffrey V Siebers; Jeffrey F Williamson
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

3.  Technical Note: Measurement of bow tie profiles in CT scanners using radiochromic film.

Authors:  Bruce R Whiting; Andreea C Dohatcu; Joshua D Evans; David G Politte; Jeffrey F Williamson
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

4.  Technical Note: On the accuracy of parametric two-parameter photon cross-section models in dual-energy CT applications.

Authors:  Dong Han; Mariela A Porras-Chaverri; Joseph A O'Sullivan; David G Politte; Jeffrey F Williamson
Journal:  Med Phys       Date:  2017-04-25       Impact factor: 4.071

5.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

Review 6.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.