Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector.

R Birch, M Marshall.   

Abstract

A method of computing theoretical X-ray spectra in the range 30-150 kV is presented. The theoretical spectra are compared with constant potential, high resolution spectra from a tungsten target measured with a Ge(Li) detector, for a range of target angles, tube voltage and filtrations. Above 100 kV the spectra were also measured with a NaI detector but, as there was good agreement between the Ge(Li) and NaI detectors, only the former are presented. Spectra computed using Kramers' theory are also included for comparison, giving fairly good agreement at large target angles (30 degrees) but becoming gradually worse as the target angle decreased. Spectra may be computed by this method for any desired filtration, target angle, and tube voltage between 30 and 150 kV, in excellent agreement with the measured data.

Entities:  

Mesh:

Year:  1979        PMID: 461510     DOI: 10.1088/0031-9155/24/3/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  36 in total

1.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Optimization of contrast-enhanced spectral mammography depending on clinical indication.

Authors:  Clarisse Dromain; Sandra Canale; Sylvie Saab-Puong; Ann-Katherine Carton; Serge Muller; Eva Maria Fallenberg
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-30

3.  Modeling and measurement of the detector presampling MTF of a variable resolution x-ray CT scanner.

Authors:  Roman Melnyk; Frank A DiBianca
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

4.  CT scanner x-ray spectrum estimation from transmission measurements.

Authors:  Xinhui Duan; Jia Wang; Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

5.  Practical calibration curve of small-type optically stimulated luminescence (OSL) dosimeter for evaluation of entrance skin dose in the diagnostic X-ray region.

Authors:  Kazuki Takegami; Hiroaki Hayashi; Hiroki Okino; Natsumi Kimoto; Itsumi Maehata; Yuki Kanazawa; Tohru Okazaki; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2015-05-15

6.  Segmentation-free x-ray energy spectrum estimation for computed tomography using dual-energy material decomposition.

Authors:  Wei Zhao; Lei Xing; Qiude Zhang; Qingguo Xie; Tianye Niu
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-30

7.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

8.  Conversion coefficients for determining organ doses in paediatric spine radiography.

Authors:  Michael Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-02-09

9.  Tungsten anode spectral model using interpolating cubic splines: unfiltered x-ray spectra from 20 kV to 640 kV.

Authors:  Andrew M Hernandez; John M Boone
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

10.  Numerical simulation of x-ray luminescence optical tomography for small-animal imaging.

Authors:  Changqing Li; Arnulfo Martínez-Dávalos; Simon R Cherry
Journal:  J Biomed Opt       Date:  2014-04       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.