| Literature DB >> 30443303 |
Hakimeh Siadat1,2, Hossain Najafi2,1, Marzieh Alikhasi3,2, Babak Falahi4, Elaheh Beyabanaki5, Farid Zayeri6,7.
Abstract
Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categorized into two groups: external hexagon (Branemark) and internal hexagon connection (Noble Active) and two implants as controls. The abutments were tightened to a 35 Ncm torque. Initial torque loss (ITL) was measured five minutes after retightening the abutment, using a digital torque wrench. The samples were covered with putty material to the abutment‒implant junction. Customized metal crowns with 45° inclinations were placed on the abutments and cyclic loading was performed accordingly. Thereafter, the secondary torque loss (STL) was measured. Microleakage test was also performed. Data were analyzed with Mann-Whitney and Wilcoxon tests (α=0.05). Results. There were no statistically significant differences between the two phases of gamma counting between and within two groups (P>0.05). However, STL after cyclic loading was less than ITL in both groups (P=0.042). Conclusion. Connection type and cyclic loading had no significant effect on microleakage. Furthermore, the internal connection had less TL as compared to the external connection. In addition, the STLs were less than ITLs in both groups.Entities:
Keywords: Dental implant‒abutment connection; gamma rays; leakage; torque
Year: 2018 PMID: 30443303 PMCID: PMC6231156 DOI: 10.15171/joddd.2018.028
Source DB: PubMed Journal: J Dent Res Dent Clin Dent Prospects ISSN: 2008-210X
Figure 1
Figure 2
Figure 3
Figure 4Comparison of the initial and secondary torque loss (ITL, STL) and percent of torque loss (PTL) within and between two groups
|
|
|
|
|
|
|
|
|
|
| 7.40±1.82 | 21.40±22.70 | 0.042 | 14.00±2.35 | 0.008 |
|
| 8.60±2.07 | 12.00±3.67 | 0.042 | 3.40±1.82 | ||
|
|
| 21.20±5.45 | 61.00±7.78 | 0.042 | 39.80±6.83 | 0.008 |
|
| 24.40±5.90 | 34.20±10.62 | 0.043 | 9.80±5.49 |
*From Wilcoxon test for comparing ITL and STL values within each group.
**From Mann-Whitney test for comparing mean differences between the two groups.
Comparison of microleakage before and after cyclic loading within and between two groups
|
|
|
|
|
|
|
|
| 13657.60±12796.95 | 22004.00±25352.06 | 0.893 | 8346.40±31360.29 | 0.841 |
|
| 16045.60±6607.33 | 26337.40±16330.67 | 0.225 | 10291.80±19108.17 |
*From Wilcoxon test for comparing gamma count before and after cyclic loading within each group.
**From Mann-Whitney test for comparing mean differences between the two groups.