Literature DB >> 21889002

Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology.

Keith L Guzaitis1, Kent L Knoernschild, Marlos A G Viana.   

Abstract

STATEMENT OF PROBLEM: Clinicians must know if a new screw can predictably increase reverse torque after multiple screw insertion cycles.
PURPOSE: The purpose of this study was (1) to compare the effect of multiple implant prosthetic screw insertion and removal cycles on reverse torque, (2) to determine whether a new screw, after multiple screw insertion cycles, affects reverse torque, and (3) to assess implant and prosthetic screw thread surface morphology with scanning electron microscopy (SEM).
MATERIAL AND METHODS: One primary screw was paired with an implant (MT Osseospeed) and inserted to 25 Ncm torque 9, 19, 29, or 39 times (n=10). Primary screw reverse torque values were recorded after each insertion. A second, reference screw was then paired with each implant for a final screw insertion, and reverse torque was measured. Maximum, minimum, median, and mean values (P(max), P(min), P(median), and P(mean)) were identified for primary screws. A 1-way ANOVA and Tukey HSD post hoc analysis assessed the influence of multiple screw insertion cycles on P(max), P(min), P(median), and P(mean) values (α=.05). Confidence intervals were used to test differences between reference (REF) screw data and corresponding DMAX and DMIN (DMAX=P(max)-REF; DMIN=P(min)-REF). The surface topography of an unused implant and screw and of 1 implant and screw from each group was evaluated with SEM.
RESULTS: Pairwise comparisons showed that 9 or fewer insertion cycles resulted in significantly greater mean reverse torque (20.9 ± 0.5 Ncm; P<.01). After 19, 29, or 39 cycles, the second, reference screw achieved significantly greater reverse torque than the minimum recorded values (P<.05). Implant thread surface morphology changes occurred primarily during the first 10 insertions.
CONCLUSIONS: After 10 screw insertion cycles, a new prosthetic screw should be used with the implant system tested to maximize screw reverse torque and maintain preload when an abutment is definitively placed.
Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21889002     DOI: 10.1016/S0022-3913(11)60115-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading.

Authors:  T Paepoemsin; P A Reichart; P Chaijareenont; F P Strietzel; P Khongkhunthian
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

2.  Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

Authors:  Woong-Rae Cho; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

3.  In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening.

Authors:  Onur Dincer Kose; Burcin Karataslı; Sabit Demircan; Taha Emre Kose; Erhan Cene; Serhan Aydın Aya; Mehmet Ali Erdem; Abdulkadir Burak Cankaya
Journal:  Biomed Res Int       Date:  2017-04-03       Impact factor: 3.411

Review 4.  Systematic analysis of factors that cause loss of preload in dental implants.

Authors:  S Nithyapriya; A S Ramesh; A Kirubakaran; Jeevitha Mani; J Raghunathan
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

5.  Tightening torque of implant abutment using hand drivers against torque wrench and its effect on the internal surface of implant.

Authors:  Y Sameera; Rathika Rai
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

6.  Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections.

Authors:  Hakimeh Siadat; Hossain Najafi; Marzieh Alikhasi; Babak Falahi; Elaheh Beyabanaki; Farid Zayeri
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-09-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.