Literature DB >> 22814560

An in vitro investigation concerning the bacterial leakage at implants with internal hexagon and Morse taper implant-abutment connections.

Domenico Tripodi1, Giovanni Vantaggiato, Antonio Scarano, Vittoria Perrotti, Adriano Piattelli, Giovanna Iezzi, Simonetta DʼErcole.   

Abstract

PURPOSE: To evaluate, in vitro, the leakage observed in internal hexagon and Morse taper implant-abutment connections. MATERIALS: Ten specimens with internal hexagon and 10 with Cone Morse connection were used. The inner parts of 5 implants, per group, were inoculated with Pseudomonas aeruginosa (PS) suspension and 5 implants, per group, with Aggregatibacter actinomycetemcomitans (AA). The penetration of bacterial suspension into the surrounding solution was determined by observation of turbidity of the broth.
RESULTS: In the internal hexagon implants, bacterial contamination was found in 2 of 5 implant-abutment assemblies seeded with the PS, and in the assemblies seeded with AA, the contamination was found in 3 samples, with a total of leaked assemblies in this group in 5 of 10. In the Cone Morse implants, bacterial contamination was found in 2 of 5 implant-abutment assemblies seeded with the PS, whereas in the assemblies seeded with AA, no contamination was found, with a total of leaked assemblies in 2 of 10.
CONCLUSION: The data support a not significantly higher permeability to bacterial leakage and a lower infiltration rate of screw-retained abutment connections when compared to Cone Morse taper internal connections.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22814560     DOI: 10.1097/ID.0b013e31825cd472

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  12 in total

1.  Effects of multiple implantations of titanium healing abutments: Surface characteristics and microbial colonization.

Authors:  Sanjana S Jain; Sareda T J Schramm; Danyal A Siddiqui; Wenwen Huo; Kelli L Palmer; Thomas G Wilson; Danieli C Rodrigues
Journal:  Dent Mater       Date:  2020-06-24       Impact factor: 5.304

2.  3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.

Authors:  M DI Girolamo; L Baggi; P Pirelli; L Pappalardo; G Massei; F Iaculli; G Iezzi; A Piattelli; R Calcaterra
Journal:  Oral Implantol (Rome)       Date:  2017-11-30

3.  A challenging journey of maxillofacial implants placement and rehabilitation in an irradiated exenterated socket.

Authors:  Radhika Jain; Modhupa Ghosh; Ruchi Goel; Rekha Gupta; Priyanka Golhait; Basudeb Ghosh
Journal:  J Oral Biol Craniofac Res       Date:  2022-04-04

Review 4.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

5.  In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection.

Authors:  Hooman Khorshidi; Saeed Raoofi; Afagh Moattari; Atoosa Bagheri; Mohammad Hassan Kalantari
Journal:  Int J Biomater       Date:  2016-05-03

Review 6.  Microbial Profiles and Detection Techniques in Peri-Implant Diseases: a Systematic Review.

Authors:  Miguel Padial-Molina; Jesús López-Martínez; Francisco O'Valle; Pablo Galindo-Moreno
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

7.  Peri-Implant Bone Resorption during Healing Abutment Placement: The Effect of a 0.20% Chlorhexidine Gel vs. Placebo-A Randomized Double Blind Controlled Human Study.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Ilaria De Tullio; Tonino Traini; Sergio Caputi
Journal:  Biomed Res Int       Date:  2018-10-16       Impact factor: 3.411

8.  A Comparative 3D Finite Element Computational Study of Three Connections.

Authors:  Davide Farronato; Mattia Manfredini; Andrea Stevanello; Veronica Campana; Lorenzo Azzi; Marco Farronato
Journal:  Materials (Basel)       Date:  2019-09-26       Impact factor: 3.623

9.  In vitro Candida albicans biofilm formation on different titanium surface topographies.

Authors:  Mathieu Mouhat; Robert Moorehead; Craig Murdoch
Journal:  Biomater Investig Dent       Date:  2020-10-09

10.  Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections.

Authors:  Hakimeh Siadat; Hossain Najafi; Marzieh Alikhasi; Babak Falahi; Elaheh Beyabanaki; Farid Zayeri
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-09-18
View more