Literature DB >> 10074758

Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study.

M Gross1, I Abramovich, E I Weiss.   

Abstract

Microleakage can occur at the abutment-implant (A-I) interface in osseointegrated implants and may cause malodor and inflammation of peri-implant tissues. The degree of microleakage at the A-I interface of 5 implant systems was comparatively assessed at varying closing torques. Using colored tracing probes driven by a 2-atm pressure system, the interface microleakage of Brånemark, Sulzer Calcitek, 3i, ITI, and Steri-Oss implants was determined spectrophotometrically. Microleakage through the A-I interface occurred in all systems, with variability between systems, samples, and closing torques. As closing torque increased from 10 Ncm to 20 Ncm to manufacturers' recommended closing torques, microleakage decreased significantly (P < .005) for all systems. Analysis of variance showed significant interaction between closing torques and the time course of microleakage, and between systems and the time course of microleakage (P < .001). The results indicate that fluids and small molecules are capable of passing through the interface of all the A-I assemblies studied. Presumably in an in situ situation, fluids containing bacterial byproducts and nutrients required for bacterial growth may pass through the interface gap, contributing in part to clinically observed malodor and peri-implantitis.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10074758

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  23 in total

1.  Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.

Authors:  Sönke Harder; Birka Dimaczek; Yaha Açil; Hendrik Terheyden; Sandra Freitag-Wolf; Matthias Kern
Journal:  Clin Oral Investig       Date:  2009-07-23       Impact factor: 3.573

2.  Bacterial diversity of periodontal and implant-related sites detected by the DNA Checkerboard method.

Authors:  C do Nascimento; N Monesi; I Y Ito; J P M Issa; R F de Albuquerque Junior
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-30       Impact factor: 3.267

3.  Bacterial contamination along implant-abutment interface in external and internal-hex dental implants.

Authors:  Greison Rabelo de Oliveira; Sergio Olate; Leandro Pozzer; Lucas Cavalieri-Pereira; Jaime G Rodrigues-Chessa; José Ricardo Albergaría-Barbosa
Journal:  Int J Clin Exp Med       Date:  2014-03-15

4.  Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth.

Authors:  D Martin-Gili; M Molmeneu; M Fernandez; M Punset; Ll Giner; J Armengou; F Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2015-07-15       Impact factor: 3.896

5.  Analysis of the intraimplant microflora of two-piece dental implants.

Authors:  Sönke Harder; Rainer Podschun; Livia Grancicova; Christian Mehl; Matthias Kern
Journal:  Clin Oral Investig       Date:  2012-09-08       Impact factor: 3.573

6.  Micro-leakage at the implant-abutment interface with different tightening torques in vitro.

Authors:  João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

7.  Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment.

Authors:  Jacques-Henri Torres; Michael Mechali; Olivier Romieu; Paul Tramini; Sylvie Callas; Frédéric Jg Cuisinier; Bernard Levallois
Journal:  Biomed Eng Online       Date:  2011-04-14       Impact factor: 2.819

8.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

9.  Peri-implant crestal bone loss: a putative mechanism.

Authors:  Yuko Ujiie; Reynaldo Todescan; John E Davies
Journal:  Int J Dent       Date:  2012-10-02

10.  Accuracy combining different brands of implants and abutments.

Authors:  María-Fernanda Solá-Ruíz; Eduardo Selva-Otaolaurruchi; Gisela Senent-Vicente; Inés González-de-Cossio; Vicente Amigó-Borrás
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.