Microbial leakage and marginal fit of the implant-abutment interface.

V K Jansen1, G Conrads, E J Richter.   

Abstract

Two-stage implant systems result in gaps and cavities between implant and abutment that can act as a trap for bacteria and thus possibly cause inflammatory reactions in the peri-implant soft tissues. These gaps between the components are inevitable, and their clinical significance has so far been mostly neglected by both manufacturers and clinicians. The aim of the study was to determine whether there is microbial leakage at the implant-abutment interface. Thirteen different implant-abutment combinations were subjected to an in vitro experiment, in which the penetration of bacteria (Escherichia coli) was observed for 10 assemblies of each type. All implant systems presented microbial leakage. When the Frialit-2 implant was supplied with a silicon washer, there were fewer cases of leakage. The width of the marginal gap between the prefabricated components, measured with a scanning electron microscope, was less than 10 microns in all systems.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9274082

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  35 in total

1.  Implant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study.

Authors:  Davide Apicella; Mario Veltri; Nicoletta Chieffi; Antonella Polimeni; Agostino Giovannetti; Marco Ferrari
Journal:  Ann Stomatol (Roma)       Date:  2011-02-13

2.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

3.  External versus internal abutment connection implants: a survey of opinions and decision making among experienced implant dentists in Japan.

Authors:  Yoshiyuki Hagiwara; Alan B Carr
Journal:  Odontology       Date:  2013-12-17       Impact factor: 2.634

4.  Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.

Authors:  Sönke Harder; Birka Dimaczek; Yaha Açil; Hendrik Terheyden; Sandra Freitag-Wolf; Matthias Kern
Journal:  Clin Oral Investig       Date:  2009-07-23       Impact factor: 3.573

5.  Bacterial diversity of periodontal and implant-related sites detected by the DNA Checkerboard method.

Authors:  C do Nascimento; N Monesi; I Y Ito; J P M Issa; R F de Albuquerque Junior
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-30       Impact factor: 3.267

6.  Bacterial contamination along implant-abutment interface in external and internal-hex dental implants.

Authors:  Greison Rabelo de Oliveira; Sergio Olate; Leandro Pozzer; Lucas Cavalieri-Pereira; Jaime G Rodrigues-Chessa; José Ricardo Albergaría-Barbosa
Journal:  Int J Clin Exp Med       Date:  2014-03-15

7.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

8.  Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth.

Authors:  D Martin-Gili; M Molmeneu; M Fernandez; M Punset; Ll Giner; J Armengou; F Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2015-07-15       Impact factor: 3.896

9.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

10.  In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.

Authors:  Deceles Cristina Costa Alves; Paulo Sérgio Perri de Carvalho; Carlos Nelson Elias; Eduardo Vedovatto; Elizabeth Ferreira Martinez
Journal:  Clin Oral Investig       Date:  2016-02-20       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.