Literature DB >> 7615325

Nonlinear contact analysis of preload in dental implant screws.

R L Sakaguchi1, S E Borgersen.   

Abstract

Clinical studies indicate that loosening or fracture of dental implant prostheses occurs in 5% to 45% of cases during the first year. The nature of loosening or displacement of prosthetic components is complex, since it involves cycling fatigue, oral fluids, and varied chewing patterns and loads. A finite element contact analysis method was used to study the load-transfer mechanism between prosthetic components caused by torque application to the threaded fasteners used for assembly. Screw elongation is achieved while allowing for elastic recovery of the screw to produce a clamping force on the fastened elements. Clamping forces were additive along the axis of the prosthetic components. When the gold retaining screw is fastened into the abutment screw, clamping force on the implant is increased at the expense of decreasing the clamping force at the abutment screw-abutment interface by 50%. Maximum tensile stresses in the screws after preload were less than 55% of the yield stress.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7615325

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  Stress distribution inside bone after suture anchor insertion: simulation using a three-dimensional finite element method.

Authors:  Hirotaka Sano; Atsushi Takahashi; Daisuke Chiba; Taku Hatta; Nobuyuki Yamamoto; Eiji Itoi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-24       Impact factor: 4.342

2.  Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading.

Authors:  T Paepoemsin; P A Reichart; P Chaijareenont; F P Strietzel; P Khongkhunthian
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

3.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage.

Authors:  Min-Jeong Kim; Sung-Ok Hong
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

5.  Correlation between microleakage and screw loosening at implant-abutment connection.

Authors:  Cem Sahin; Simel Ayyildiz
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

6.  Influence of the implant-abutment connection design and diameter on the screw joint stability.

Authors:  Hyon-Mo Shin; Jung-Bo Huh; Mi-Jeong Yun; Young-Chan Jeon; Brian Myung Chang; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

Review 7.  Systematic analysis of factors that cause loss of preload in dental implants.

Authors:  S Nithyapriya; A S Ramesh; A Kirubakaran; Jeevitha Mani; J Raghunathan
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

8.  Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study).

Authors:  Eman Mohammed Nasr Attiah; Attiah Ali AlGendy; Tamer Mohamed Nasr Mostafa
Journal:  Int J Implant Dent       Date:  2020-07-28

Review 9.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

10.  Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible.

Authors:  Kyung-Hoi Heo; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.