Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Nan-Kuei Chen1, Alexandru V Avram, Allen W Song.   

Abstract

The inconsistency of k-space trajectories results in Nyquist artifacts in echo-planar imaging (EPI). Traditional techniques often only correct for phase errors along the frequency-encoding direction (one-dimensional correction), which may leave significant residual artifacts, particularly for oblique-plane EPI or in the presence of cross-term eddy currents. As compared with one-dimensional correction, two-dimensional (2D) phase correction can be much more effective in suppressing Nyquist artifacts. However, most existing 2D correction methods require reference scans and may not be generally applicable to different imaging protocols. Furthermore, EPI reconstruction with these 2D phase correction methods is susceptible to error amplification due to subject motion. To address these limitations, we report an inherent and general 2D phase correction technique for EPI Nyquist removal. First, a series of images are generated from the original dataset, by cycling through different possible values of phase errors using a 2D reconstruction framework. Second, the image with the lowest artifact level is identified from images generated in the first step using criteria based on background energy in sorted and sigmoid-weighted signals. In this report, we demonstrate the effectiveness of our new method in removing Nyquist ghosts in single-shot, segmented and parallel EPI without acquiring additional reference scans and the subsequent error amplifications.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21446032      PMCID: PMC3311129          DOI: 10.1002/mrm.22896

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

Authors:  P Kellman; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Image-based ghost correction for interleaved EPI.

Authors:  M H Buonocore; D C Zhu
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

4.  Elimination of Nyquist ghosting caused by read-out to phase-encode gradient cross-terms in EPI.

Authors:  Stuart M Grieve; Andrew M Blamire; Peter Styles
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

5.  Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction.

Authors:  Nan-kuei Chen; Alice M Wyrwicz
Journal:  Magn Reson Med       Date:  2004-06       Impact factor: 4.668

6.  Image reconstruction for echo planar imaging with nonequidistant k-space sampling.

Authors:  H Bruder; H Fischer; H E Reinfelder; F Schmitt
Journal:  Magn Reson Med       Date:  1992-02       Impact factor: 4.668

7.  Robust 2D phase correction for echo planar imaging under a tight field-of-view.

Authors:  Dan Xu; Kevin F King; Yuval Zur; R Scott Hinks
Journal:  Magn Reson Med       Date:  2010-08-30       Impact factor: 4.668

8.  Artifact reduction in EPI with phase-encoded reference scan.

Authors:  X Hu; T H Le
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

9.  Ghost artifact reduction for echo planar imaging using image phase correction.

Authors:  M H Buonocore; L Gao
Journal:  Magn Reson Med       Date:  1997-07       Impact factor: 4.668

10.  Magnetic resonance fast Fourier imaging.

Authors:  J J Cuppen; J P Groen; J Konijn
Journal:  Med Phys       Date:  1986 Mar-Apr       Impact factor: 4.071

View more
  16 in total

1.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

Authors:  Benedikt A Poser; Markus Barth; Pål-Erik Goa; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

3.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

4.  Dynamic 2D self-phase-map Nyquist ghost correction for simultaneous multi-slice echo planar imaging.

Authors:  Uten Yarach; Yi-Hang Tung; Kawin Setsompop; Myung-Ho In; Itthi Chatnuntawech; Renat Yakupov; Frank Godenschweger; Oliver Speck
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

5.  Interleaved diffusion-weighted improved by adaptive partial-Fourier and multiband multiplexed sensitivity-encoding reconstruction.

Authors:  Hing-Chiu Chang; Shayan Guhaniyogi; Nan-Kuei Chen
Journal:  Magn Reson Med       Date:  2014-06-12       Impact factor: 4.668

6.  The use of Fourier-domain analyses for unwrapping phase images of low SNR.

Authors:  Nan-Kuei Chen; Pei-Hsin Wu
Journal:  Magn Reson Med       Date:  2019-03-12       Impact factor: 4.668

7.  Motion immune diffusion imaging using augmented MUSE for high-resolution multi-shot EPI.

Authors:  Shayan Guhaniyogi; Mei-Lan Chu; Hing-Chiu Chang; Allen W Song; Nan-Kuei Chen
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

8.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

9.  A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE).

Authors:  Nan-Kuei Chen; Arnaud Guidon; Hing-Chiu Chang; Allen W Song
Journal:  Neuroimage       Date:  2013-01-28       Impact factor: 6.556

10.  Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Authors:  Hing-Chiu Chang; Nan-Kuei Chen
Journal:  Magn Reson Imaging       Date:  2016-04-22       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.