Literature DB >> 11323811

Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

P Kellman1, F H Epstein, E R McVeigh.   

Abstract

A number of different methods have been demonstrated which increase the speed of MR acquisition by decreasing the number of sequential phase encodes. The UNFOLD technique is based on time interleaving of k-space lines in sequential images and exploits the property that the outer portion of the field-of-view is relatively static. The differences in spatial sensitivity of multiple receiver coils may be exploited using SENSE or SMASH techniques to eliminate the aliased component that results from undersampling k-space. In this article, an adaptive method of sensitivity encoding is presented which incorporates both spatial and temporal filtering. Temporal filtering and spatial encoding may be combined by acquiring phase encodes in an interleaved manner. In this way the aliased components are alternating phase. The SENSE formulation is not altered by the phase of the alias artifact; however, for imperfect estimates of coil sensitivities the residual artifact will have alternating phase using this approach. This is the essence of combining temporal filtering (UNFOLD) with spatial sensitivity encoding (SENSE). Any residual artifact will be temporally frequency-shifted to the band edge and thus may be further suppressed by temporal low-pass filtering. By combining both temporal and spatial filtering a high degree of alias artifact rejection may be achieved with less stringent requirements on accuracy of coil sensitivity estimates and temporal low-pass filter selectivity than would be required using each method individually. Experimental results that demonstrate the adaptive spatiotemporal filtering method (adaptive TSENSE) with acceleration factor R = 2, for real-time nonbreath-held cardiac MR imaging during exercise induced stress are presented.

Mesh:

Year:  2001        PMID: 11323811     DOI: 10.1002/mrm.1113

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  116 in total

1.  Reconstruction of dynamic image series from undersampled MRI data using data-driven model consistency condition (MOCCO).

Authors:  Julia V Velikina; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-14       Impact factor: 4.668

2.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

3.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

4.  Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Authors:  P Kellman; J A Derbyshire; K O Agyeman; E R McVeigh; A E Arai
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.

Authors:  Michael A Guttman; Peter Kellman; Alexander J Dick; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

6.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Authors:  W Scott Hoge; Huan Tan; Robert A Kraft
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

7.  Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment.

Authors:  Federico E Mordini; Tariq Haddad; Li-Yueh Hsu; Peter Kellman; Tracy B Lowrey; Anthony H Aletras; W Patricia Bandettini; Andrew E Arai
Journal:  JACC Cardiovasc Imaging       Date:  2014-01

8.  Sliding-window sensitivity encoding (SENSE) calibration for reducing noise in functional MRI (fMRI).

Authors:  Christine S Law; Chunlei Liu; Gary H Glover
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

9.  Auto-SENSE view-sharing cine cardiac imaging.

Authors:  H Köstler; M Beer; C Ritter; D Hahn; J Sandstede
Journal:  MAGMA       Date:  2004-08-28       Impact factor: 2.310

Review 10.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.