Literature DB >> 25762216

Motion immune diffusion imaging using augmented MUSE for high-resolution multi-shot EPI.

Shayan Guhaniyogi1, Mei-Lan Chu1, Hing-Chiu Chang1, Allen W Song1, Nan-Kuei Chen1.   

Abstract

PURPOSE: To develop new techniques for reducing the effects of microscopic and macroscopic patient motion in diffusion imaging acquired with high-resolution multishot echo-planar imaging. THEORY: The previously reported multiplexed sensitivity encoding (MUSE) algorithm is extended to account for macroscopic pixel misregistrations, as well as motion-induced phase errors in a technique called augmented MUSE (AMUSE). Furthermore, to obtain more accurate quantitative diffusion-tensor imaging measures in the presence of subject motion, we also account for the altered diffusion encoding among shots arising from macroscopic motion.
METHODS: MUSE and AMUSE were evaluated on simulated and in vivo motion-corrupted multishot diffusion data. Evaluations were made both on the resulting imaging quality and estimated diffusion tensor metrics.
RESULTS: AMUSE was found to reduce image blurring resulting from macroscopic subject motion compared to MUSE but yielded inaccurate tensor estimations when neglecting the altered diffusion encoding. Including the altered diffusion encoding in AMUSE produced better estimations of diffusion tensors.
CONCLUSION: The use of AMUSE allows for improved image quality and diffusion tensor accuracy in the presence of macroscopic subject motion during multishot diffusion imaging. These techniques should facilitate future high-resolution diffusion imaging.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  diffusion-tensor imaging; diffusion-weighted imaging; echo-planar imaging; high resolution; motion; multiplexed sensitivity encoding

Mesh:

Year:  2015        PMID: 25762216      PMCID: PMC4567534          DOI: 10.1002/mrm.25624

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  49 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  In vivo fiber tractography using DT-MRI data.

Authors:  P J Basser; S Pajevic; C Pierpaoli; J Duda; A Aldroubi
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

3.  Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging.

Authors:  D Atkinson; D A Porter; D L Hill; F Calamante; A Connelly
Journal:  Magn Reson Med       Date:  2000-07       Impact factor: 4.668

4.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

5.  A global optimisation method for robust affine registration of brain images.

Authors:  M Jenkinson; S Smith
Journal:  Med Image Anal       Date:  2001-06       Impact factor: 8.545

6.  Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.

Authors:  Chunlei Liu; Roland Bammer; Dong-Hyun Kim; Michael E Moseley
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

7.  High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.

Authors:  Tie-Qiang Li; Dong-Hyun Kim; Michael E Moseley
Journal:  J Magn Reson Imaging       Date:  2005-04       Impact factor: 4.813

8.  PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions.

Authors:  Fu-Nien Wang; Teng-Yi Huang; Fa-Hsuan Lin; Tzu-Chao Chuang; Nan-Kuei Chen; Hsiao-Wen Chung; Cheng-Yu Chen; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

9.  Advantages of adding diffusion-weighted magnetic resonance imaging to conventional magnetic resonance imaging for evaluating acute stroke.

Authors:  M G Lansberg; A M Norbash; M P Marks; D C Tong; M E Moseley; G W Albers
Journal:  Arch Neurol       Date:  2000-09

10.  Brain abscess and necrotic brain tumor: discrimination with proton MR spectroscopy and diffusion-weighted imaging.

Authors:  Ping H Lai; Jih T Ho; Wei L Chen; Shu S Hsu; Jyh S Wang; Huay B Pan; Chien F Yang
Journal:  AJNR Am J Neuroradiol       Date:  2002-09       Impact factor: 3.825

View more
  14 in total

Review 1.  Pediatric skeletal diffusion-weighted magnetic resonance imaging: part 1 - technical considerations and optimization strategies.

Authors:  Apeksha Chaturvedi
Journal:  Pediatr Radiol       Date:  2021-04-01

2.  Structure tensor informed fibre tractography at 3T.

Authors:  Kwok-Shing Chan; David G Norris; José P Marques
Journal:  Hum Brain Mapp       Date:  2018-07-21       Impact factor: 5.038

3.  Echo planar time-resolved imaging (EPTI).

Authors:  Fuyixue Wang; Zijing Dong; Timothy G Reese; Berkin Bilgic; Mary Katherine Manhard; Jingyuan Chen; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-02-03       Impact factor: 4.668

4.  Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3Tesla clinical MRI scanner.

Authors:  Hing-Chiu Chang; Mark Sundman; Laurent Petit; Shayan Guhaniyogi; Mei-Lan Chu; Christopher Petty; Allen W Song; Nan-kuei Chen
Journal:  Neuroimage       Date:  2015-06-11       Impact factor: 6.556

5.  Multi-shot sensitivity-encoded diffusion data recovery using structured low-rank matrix completion (MUSSELS).

Authors:  Merry Mani; Mathews Jacob; Douglas Kelley; Vincent Magnotta
Journal:  Magn Reson Med       Date:  2016-08-23       Impact factor: 4.668

6.  High-Spatial-Resolution Multishot Multiplexed Sensitivity-encoding Diffusion-weighted Imaging for Improved Quality of Breast Images and Differentiation of Breast Lesions: A Feasibility Study.

Authors:  Isaac Daimiel Naranjo; Roberto Lo Gullo; Elizabeth A Morris; Toni Larowin; Maggie M Fung; Arnaud Guidon; Katja Pinker; Sunitha B Thakur
Journal:  Radiol Imaging Cancer       Date:  2020-05-29

7.  Motion-robust sub-millimeter isotropic diffusion imaging through motion corrected generalized slice dithered enhanced resolution (MC-gSlider) acquisition.

Authors:  Fuyixue Wang; Berkin Bilgic; Zijing Dong; Mary Kate Manhard; Ned Ohringer; Bo Zhao; Melissa Haskell; Stephen F Cauley; Qiuyun Fan; Thomas Witzel; Elfar Adalsteinsson; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2018-04-01       Impact factor: 4.668

8.  Motion-robust reconstruction of multishot diffusion-weighted images without phase estimation through locally low-rank regularization.

Authors:  Yuxin Hu; Evan G Levine; Qiyuan Tian; Catherine J Moran; Xiaole Wang; Valentina Taviani; Shreyas S Vasanawala; Jennifer A McNab; Bruce A Daniel; Brian L Hargreaves
Journal:  Magn Reson Med       Date:  2018-10-22       Impact factor: 4.668

9.  Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Authors:  Hing-Chiu Chang; Nan-Kuei Chen
Journal:  Magn Reson Imaging       Date:  2016-04-22       Impact factor: 2.546

10.  RUN-UP: Accelerated multishot diffusion-weighted MRI reconstruction using an unrolled network with U-Net as priors.

Authors:  Yuxin Hu; Yunyingying Xu; Qiyuan Tian; Feiyu Chen; Xinwei Shi; Catherine J Moran; Bruce L Daniel; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2020-08-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.