Image-based ghost correction for interleaved EPI.

M H Buonocore1, D C Zhu.   

Abstract

A new image-based ghost correction technique is described for general interleaved EPI. This technique works reliably with both even- and odd-number interleaved EPI sequences. It estimates the phase distortions causing the ghosts as a general function of (x,y) even in the presence of a significant overlap of parent image and ghosts. If the phase distortion is assumed to be a function of x (frequency-encode direction) only, the new technique is similar to a recently published correction method for general interleaved EPI (Hennel. J Magn Reson 1998;134:206-213). However, that study concluded that the method for general interleaved EPI did not work. It showed that the SNRs of the edge pixels were too low to accurately estimate the phase distortion. The new technique utilizes not one, but many pixels in the image for estimating the phase distortion. The technique requires a user-defined ROI to outline the parent image and identify so-called eligible pixels for estimating the phase distortion. When all eligible pixels are used, the SNR of the phase distortion estimate is comparable to that obtained in single-shot EPI. This study provides the first examples of high-quality, image-based correction of multiple ghosts in general interleaved EPI. Magn Reson Med 45:96-108, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11146491     DOI: 10.1002/1522-2594(200101)45:1<96::aid-mrm1014>3.0.co;2-j

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.

Authors:  Jun-Young Chung; Yeji Han; Zang-Hee Cho; Hyunwook Park
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

2.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Authors:  W Scott Hoge; Huan Tan; Robert A Kraft
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

3.  Atlas-based multichannel monitoring of functional MRI signals in real-time: automated approach.

Authors:  Jong-Hwan Lee; Heather M O'Leary; Hyunwook Park; Ferenc A Jolesz; Seung-Schik Yoo
Journal:  Hum Brain Mapp       Date:  2008-02       Impact factor: 5.038

4.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

5.  Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Authors:  Nan-Kuei Chen; Alexandru V Avram; Allen W Song
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

6.  Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

Authors:  Julianna D Ianni; E Brian Welch; William A Grissom
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

7.  Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data.

Authors:  W Scott Hoge; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2015-07-24       Impact factor: 4.668

8.  Free-breathing 3D diffusion MRI for high-resolution hepatic metastasis characterization in small animals.

Authors:  Emeline J Ribot; Aurélien J Trotier; Charles R Castets; Benjamin Dallaudière; Eric Thiaudière; Jean-Michel Franconi; Sylvain Miraux
Journal:  Clin Exp Metastasis       Date:  2015-11-05       Impact factor: 5.150

9.  A Robust Method for Estimating B0 Inhomogeneity Field in the Liver by Mitigating Fat Signals and Phase-Wrapping.

Authors:  Antonis Matakos; James M Balter; Yue Cao
Journal:  Tomography       Date:  2017-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.