Literature DB >> 1549045

Image reconstruction for echo planar imaging with nonequidistant k-space sampling.

H Bruder1, H Fischer, H E Reinfelder, F Schmitt.   

Abstract

Echo planar imaging is characterized by scanning the 2D k-space after a single excitation. Different sampling patterns have been proposed. A technically feasible method uses a sinusoidal readout gradient resulting is measured data that does not sample k-space in an equidistant manner. In order to employ a conventional 2D-FFT image reconstruction, the data have to be converted to a cartesian grid. This can be done either by interpolation or alternatively by a generalized transformation. Filtering methods are described to minimize ghosting artifact that is typical in echo planar imaging. Results both from computer simulation and from experiments will be presented. Experimental images were obtained using a 2-T whole-body research system.

Mesh:

Year:  1992        PMID: 1549045     DOI: 10.1002/mrm.1910230211

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  56 in total

1.  A novel object-independent "balanced" reference scan for echo-planar imaging.

Authors:  S B Reeder; A Z Faranesh; E Atalar; E R McVeigh
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Two-dimensional deghosting for EPI.

Authors:  F Hennel
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

Review 3.  Echo planar imaging's impact on modern diagnostic MR-imaging: general principles and historic facts.

Authors:  M K Stehling; L Liu
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

4.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

5.  Referenceless interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

6.  MR CAT scan: a modular approach for hybrid imaging.

Authors:  C Hillenbrand; D Hahn; A Haase; P M Jakob
Journal:  MAGMA       Date:  2000-07       Impact factor: 2.310

7.  Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.

Authors:  V J Schmithorst; B J Dardzinski; S K Holland
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

8.  A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.

Authors:  Jun-Young Chung; Yeji Han; Zang-Hee Cho; Hyunwook Park
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

9.  TURBINE-MRE: A 3D hybrid radial-Cartesian EPI acquisition for MR elastography.

Authors:  Yi Sui; Arvin Arani; Joshua D Trzasko; Matthew C Murphy; Phillip J Rossman; Kevin J Glaser; Kiaran P McGee; Armando Manduca; Richard L Ehman; Philip A Araoz; John Huston
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

10.  Cortical correlates of human motion perception biases.

Authors:  Brett Vintch; Justin L Gardner
Journal:  J Neurosci       Date:  2014-02-12       Impact factor: 6.167

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.