Literature DB >> 20806354

Robust 2D phase correction for echo planar imaging under a tight field-of-view.

Dan Xu1, Kevin F King, Yuval Zur, R Scott Hinks.   

Abstract

Nyquist ghost artifacts are a serious issue in echo planar imaging. These artifacts primarily originate from phase difference between even and odd echo images and can be removed or reduced using phase correction methods. The commonly used 1D phase correction can only correct phase difference along readout axis. 2D correction is, therefore, necessary when phase difference presents along both readout and phase encoding axes. However, existing 2D methods have several unaddressed issues that affect their practicality. These issues include uncharacterized noise behavior, image artifact due to unoptimized phase estimation, Gibbs ringing artifact when directly applying to partial k(y) data, and most seriously a new image artifact under tight field-of-view (i.e., field-of-view slightly smaller than object size). All these issues are addressed in this article. Specifically, theoretical analysis of noise amplification and effect of phase estimation error is provided, and tradeoff between noise and ghost is studied. A new 2D phase correction method with improved polynomial fitting, joint homodyne processing and phase correction, compatibility with tight field-of-view is then proposed. Various results show that the proposed method can robustly generate images free of Nyquist ghosts and other image artifacts even in oblique scans or when cross-term eddy current terms are significant.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20806354     DOI: 10.1002/mrm.22577

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.

Authors:  Jun-Young Chung; Yeji Han; Zang-Hee Cho; Hyunwook Park
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

3.  Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

Authors:  Benedikt A Poser; Markus Barth; Pål-Erik Goa; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

4.  Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Authors:  Nan-Kuei Chen; Alexandru V Avram; Allen W Song
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

5.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

6.  Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

Authors:  Julianna D Ianni; E Brian Welch; William A Grissom
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

7.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

8.  Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Authors:  Hing-Chiu Chang; Nan-Kuei Chen
Journal:  Magn Reson Imaging       Date:  2016-04-22       Impact factor: 2.546

9.  New spatiotemporal approaches for fully refocused, multislice ultrafast 2D MRI.

Authors:  Rita Schmidt; Lucio Frydman
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Nyquist ghost correction of breast diffusion weighted imaging using referenceless methods.

Authors:  Jessica A McKay; Steen Moeller; Lei Zhang; Edward J Auerbach; Michael T Nelson; Patrick J Bolan
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.