Literature DB >> 29427393

Dynamic 2D self-phase-map Nyquist ghost correction for simultaneous multi-slice echo planar imaging.

Uten Yarach1, Yi-Hang Tung2, Kawin Setsompop3,4, Myung-Ho In5, Itthi Chatnuntawech6, Renat Yakupov2, Frank Godenschweger2, Oliver Speck2,7,8,9.   

Abstract

PURPOSE: To develop a reconstruction pipeline that intrinsically accounts for both simultaneous multislice echo planar imaging (SMS-EPI) reconstruction and dynamic slice-specific Nyquist ghosting correction in time-series data.
METHODS: After 1D slice-group average phase correction, the separate polarity (i.e., even and odd echoes) SMS-EPI data were unaliased by slice GeneRalized Autocalibrating Partial Parallel Acquisition. Both the slice-unaliased even and odd echoes were jointly reconstructed using a model-based framework, extended for SMS-EPI reconstruction that estimates a 2D self-phase map, corrects dynamic slice-specific phase errors, and combines data from all coils and echoes to obtain the final images.
RESULTS: The percentage ghost-to-signal ratios (%GSRs) and its temporal variations for MB3Ry 2 with a field of view/4 shift in a human brain obtained by the proposed dynamic 2D and standard 1D phase corrections were 1.37 ± 0.11 and 2.66 ± 0.16, respectively. Even with a large regularization parameter λ applied in the proposed reconstruction, the smoothing effect in fMRI activation maps was comparable to a very small Gaussian kernel size 1 × 1 × 1 mm3 .
CONCLUSION: The proposed reconstruction pipeline reduced slice-specific phase errors in SMS-EPI, resulting in reduction of GSR. It is applicable for functional MRI studies because the smoothing effect caused by the regularization parameter selection can be minimal in a blood-oxygen-level-dependent activation map.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  Nyquist ghost; SMS-EPI; self-phase map; slice-specific phase correction

Mesh:

Year:  2018        PMID: 29427393      PMCID: PMC6085172          DOI: 10.1002/mrm.27123

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  36 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

4.  A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

Authors:  Melanie Schmitt; Andreas Potthast; David E Sosnovik; Jonathan R Polimeni; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

5.  Minimization of Nyquist ghosting for echo-planar imaging at ultra-high fields based on a "negative readout gradient" strategy.

Authors:  Wietske van der Zwaag; José P Marques; Hongxia Lei; Nathalie Just; Tobias Kober; Rolf Gruetter
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

6.  Ghost artifact reduction for echo planar imaging using image phase correction.

Authors:  M H Buonocore; L Gao
Journal:  Magn Reson Med       Date:  1997-07       Impact factor: 4.668

7.  Multiband phase-constrained parallel MRI.

Authors:  Martin Blaimer; Morwan Choli; Peter M Jakob; Mark A Griswold; Felix A Breuer
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

8.  Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty.

Authors:  Kawin Setsompop; Borjan A Gagoski; Jonathan R Polimeni; Thomas Witzel; Van J Wedeen; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

9.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Two-dimensional-NGC-SENSE-GRAPPA for fast, ghosting-robust reconstruction of in-plane and slice-accelerated blipped-CAIPI echo planar imaging.

Authors:  Peter J Koopmans
Journal:  Magn Reson Med       Date:  2016-03-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.